The Hysteresis Behavior of Steel Beam-Column Joint with the Load Bearing-Energy Dissipation Connection for Converter Station Building

被引:0
|
作者
Gao, Xian [1 ]
Lin, Shaoyuan [2 ]
Liu, Ruyue [3 ]
Chen, Xilong [1 ]
机构
[1] State Grid Fujian Elect Power Co Ltd, Econ & Technol Res Inst, Fuzhou 350013, Peoples R China
[2] State Grid Fujian Elect Power Co Ltd, Fuzhou 350013, Peoples R China
[3] Fujian Univ Technol, Sch Civil Engn, Fuzhou 350108, Peoples R China
关键词
prefabricated converter station building; load bearing-energy dissipation connection; hysteresis behavior; slip length; damage concentration; SECTION;
D O I
10.3390/buildings14082424
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control. The beam-column joint is the essential constitutive part to ensure structural integrity and reliable force transmission for the prefabricated structure. In this paper, a novel load bearing-energy dissipation connection is proposed and applied to the beam-column joint to improve seismic performance and seismic resilience. Pseudo-static tests were conducted on the beam-column joint with the load bearing-energy dissipation connection, and the test results demonstrated that the tested beam-column joints developed with similar failure modes, and the damage was concentrated in the load bearing-energy dissipation connection while the beam and column remained elastic. The beam-column joint with the load bearing-energy dissipation connection had stable hysteresis behavior, with favorable bearing capacity and energy dissipation behavior. A shorter slip length and a larger bolt distance could lead to better stress development and enhance the bearing capacity, while the slip length barely affected the ductile behavior. Moreover, a finite element model was established and validated to extend the parametric study to provide a preliminary understanding of the mechanical mechanism of the proposed beam-column joint with the load bearing-energy dissipation connection. It was confirmed that the load--deformation behavior was greatly affected by the slip length, but the slip length barely affected the initial stiffness. The width of the sliding steel fuse influenced the bearing capacity and the degradation behavior. A wider width could lead to a higher bearing capacity and improve the degradation behavior. Based on the analysis of the stress development and stress distribution corresponding to different feature points, it was concluded that the use of bearing-energy dissipation improved the stress development in the framing components and achieved damage concentration.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Seismic behavior of steel beam-column connection with assembled steel rod energy dissipaters
    Zhong, Yun-Long
    Li, Guo-Qiang
    Xiang, Yang
    Wang, Yan-Bo
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [2] Seismic Performance of Precast Steel Beam-Column Joint with Bolted Connection
    Chen, Yandan
    Lu, Yonggang
    Liu, Tong
    BUILDINGS, 2024, 14 (08)
  • [3] Energy dissipation of steel-polymer composite beam-column connector
    Wang, Yun-Che
    Ko, Chih-Chin
    STEEL AND COMPOSITE STRUCTURES, 2015, 18 (05): : 1161 - 1176
  • [4] Seismic behaviour of a precast prestressed beam-column joint with energy dissipation bars
    Fan, Jiajun
    Wu, Gang
    Cao, Yu
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (07) : 365 - 378
  • [5] Analysis of beam-column joint in steel frame structure based on connection failure probability
    Yu, Hao-Ran
    Chen, Cheng
    Xu, Yan
    Li, Wei-Bin
    CIVIL ENGINEERING AND URBAN PLANNING IV, 2016, : 665 - 669
  • [6] NUMERICAL STUDY ON HYSTERETIC PERFORMANCE OF ASSEMBLED BEAM-COLUMN STEEL JOINT WITH SMA CONNECTION
    He H.-F.
    Zhou Y.-L.
    Wu M.
    Xu Z.-G.
    Wen J.-N.
    Gongcheng Lixue/Engineering Mechanics, 2023, 40 : 283 - 288
  • [7] Verification of Experimental Hysteresis Loops for Exterior Beam-Column Joint Under Lateral Cyclic Load
    Hadi, N. D.
    Hamid, N. H.
    2ND INTERNATIONAL CONFERENCE ON AGRICULTURAL TECHNOLOGY, ENGINEERING AND ENVIRONMENTAL SCIENCES, 2021, 644
  • [8] Experimental study and design methodology of sacrificial-energy dissipation beam-column joint
    Lu, Xinzheng
    Jin, Xinlei
    Tian, Yuan
    Xie, Linlin
    Wang, Yixing
    ENGINEERING STRUCTURES, 2024, 314
  • [9] Behavior of thin-walled beam-column modular connection subject to bending load
    Dhanapal, Jothiarun
    Ghaednia, Hossein
    Das, Sreekanta
    Velocci, Jonathan
    THIN-WALLED STRUCTURES, 2020, 149
  • [10] Static Bearing Capacity Investigation of a Novel Prefabricated Light-Steel Beam-Column Connection
    Wang, Xiaoping
    Liu, Fuyong
    Li, Xiangxue
    Li, Tao
    Xu, Xiaoqin
    Shui, Zhonghe
    Wu, Huancheng
    APPLIED SCIENCES-BASEL, 2022, 12 (09):