The Hysteresis Behavior of Steel Beam-Column Joint with the Load Bearing-Energy Dissipation Connection for Converter Station Building

被引:0
|
作者
Gao, Xian [1 ]
Lin, Shaoyuan [2 ]
Liu, Ruyue [3 ]
Chen, Xilong [1 ]
机构
[1] State Grid Fujian Elect Power Co Ltd, Econ & Technol Res Inst, Fuzhou 350013, Peoples R China
[2] State Grid Fujian Elect Power Co Ltd, Fuzhou 350013, Peoples R China
[3] Fujian Univ Technol, Sch Civil Engn, Fuzhou 350108, Peoples R China
关键词
prefabricated converter station building; load bearing-energy dissipation connection; hysteresis behavior; slip length; damage concentration; SECTION;
D O I
10.3390/buildings14082424
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Prefabricated converter station building has been gradually applied in the field of power engineering construction due to the advantages of standardized design, high construction efficiency, and quality control. The beam-column joint is the essential constitutive part to ensure structural integrity and reliable force transmission for the prefabricated structure. In this paper, a novel load bearing-energy dissipation connection is proposed and applied to the beam-column joint to improve seismic performance and seismic resilience. Pseudo-static tests were conducted on the beam-column joint with the load bearing-energy dissipation connection, and the test results demonstrated that the tested beam-column joints developed with similar failure modes, and the damage was concentrated in the load bearing-energy dissipation connection while the beam and column remained elastic. The beam-column joint with the load bearing-energy dissipation connection had stable hysteresis behavior, with favorable bearing capacity and energy dissipation behavior. A shorter slip length and a larger bolt distance could lead to better stress development and enhance the bearing capacity, while the slip length barely affected the ductile behavior. Moreover, a finite element model was established and validated to extend the parametric study to provide a preliminary understanding of the mechanical mechanism of the proposed beam-column joint with the load bearing-energy dissipation connection. It was confirmed that the load--deformation behavior was greatly affected by the slip length, but the slip length barely affected the initial stiffness. The width of the sliding steel fuse influenced the bearing capacity and the degradation behavior. A wider width could lead to a higher bearing capacity and improve the degradation behavior. Based on the analysis of the stress development and stress distribution corresponding to different feature points, it was concluded that the use of bearing-energy dissipation improved the stress development in the framing components and achieved damage concentration.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Cyclic Load Tests of SFRM-Insulated Steel Gravity Frame Beam-Column Connection Assemblies
    Keller, W. J.
    Pessiki, S.
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (10)
  • [22] Experimental study on deformation behavior of precast steel reinforced concrete beam-column joints with beam-beam connection
    Guan M.
    Liang Z.
    Zeng Q.
    Zhang Y.
    Wang G.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 : 9 - 15
  • [23] BEHAVIOR OF PREFABRICATED BEAM-COLUMN CONNECTION WITH SHORT STRANDS IN SELF-CENTERING STEEL FRAME
    Zhang, Yan-xia
    Li, Quan-gang
    Huang, Wei-zhen
    Jiang, Kun
    Sun, Yu
    ADVANCED STEEL CONSTRUCTION, 2019, 15 (02): : 203 - 214
  • [24] SEISMIC PERFORMANCE ANALYSIS OF NOVEL PRECAST CONCRETE BEAM-COLUMN JOINT WITH REPLACEABLE ENERGY DISSIPATION DEVICES
    Ge Q.
    Li Y.-J.
    Xiong F.
    He Y.
    Shen H.
    Li Y.
    He Y.-X.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 : 57 - 65
  • [25] Structural Behavior of Recycled Aggregate Concrete Beam-Column Connection in Presence of Micro Concrete at Joint Region
    Marthong, C.
    Sangma, A. S.
    Choudhury, S. A.
    Pyrbot, R. N.
    Tron, S. L.
    Mawroh, L.
    Bharti, G. S.
    STRUCTURES, 2017, 11 : 243 - 251
  • [26] Seismic performance analysis of steel beam to CFST column connection with ductility and energy dissipation components
    Wang, Jingxuan
    Li, Qiuying
    Wei, Guoqiang
    JOURNAL OF VIBROENGINEERING, 2020, 22 (01) : 131 - 144
  • [27] Experimental on seismic performance of replaceable splicing steel beam-column joints with friction energy dissipation components
    Diao, Yan-Song
    Ren, Yi-Jian
    Yang, Yuan-Qiang
    Zhao, Ling-Yun
    Liu, Xiu-Li
    Liu, Yun
    Jilin Daxue Xuebao (Gongxueban)/Journal of Jilin University (Engineering and Technology Edition), 2024, 54 (06): : 1643 - 1656
  • [28] Mechanical Behavior of a Novel Precast Concrete Beam-Column Joint Using the Mortise-Tenon Connection
    Zhu, Zhigang
    Wu, Fengqi
    Hao, Jing
    SUSTAINABILITY, 2023, 15 (19)
  • [29] Seismic behavior of steel and sisal fiber reinforced beam-column joint under cyclic loading
    Kavitha, S. M.
    Venkatesan, G.
    Avudaiappan, Siva
    Zhang, Chunwei
    STRUCTURAL ENGINEERING AND MECHANICS, 2023, 88 (05) : 481 - 492
  • [30] A TECHNIQUE FOR EVALUATING THE EFFECT OF BEAM-COLUMN JOINT DEFORMATION ON THE LATERAL FLEXIBILITY OF STEEL FRAME BUILDING STRUCTURES
    CHARNEY, FA
    HORVILLEUR, JF
    STRUCTURAL DESIGN OF TALL BUILDINGS, 1995, 4 (01): : 3 - 13