Multi-Organizational Insights Into Radiological Safety Standards in High-Dose Rate Brachytherapy

被引:0
|
作者
Luharia, Anurag [1 ]
Dahake, Shweta B. [1 ]
Uke, Ashish [2 ]
Mishra, Gaurav, V [3 ]
Mahakalkar, Chanrashekhar [4 ]
机构
[1] Datta Meghe Inst Higher Educ & Res, Jawaharlal Nehru Med Coll, Med Phys, Wardha, India
[2] Datta Meghe Inst Higher Educ & Res, Jawaharlal Nehru Med Coll, Radiat Oncol, Wardha, India
[3] Datta Meghe Inst Higher Educ & Res, Jawaharlal Nehru Med Coll, Radiodiag, Wardha, India
[4] Datta Meghe Inst Higher Educ & Res, Jawaharlal Nehru Med Coll, Gen Surg, Wardha, India
关键词
ncrp; aapm; iaea; sealed radioactive source safety; radiation protection; radiation safety; brachytherapy;
D O I
10.7759/cureus.65895
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The review provides an extensive study of regulations and recommendations set forth by organizations worldwide in the domain of high-dose rate (HDR) brachytherapy for the prevention and mitigation of radiation hazards. The relevant reports and publications by the International Commission on Radiological Board (AERB) were accessed, and necessary information was compiled to clarify and understand concepts, similarities, and differences in safety standards concerning to the topic. The regulations and guidance are categorized under three major components of safety, namely layout, equipment, and source. Layout category accesses structure, design, layout, and survey. The equipment category summarizes the requirements of equipment, installation, commissioning, quality assurance (QA) and performance, safety precautions and preparedness, safety procedures, and instructions. The source category includes requirements for sealed source possession and use, calibration, categorization, certification, licensing, QA tests, and security. IAEA gives inclusive guidance on radiation protection and regulatory requirements, forming the basis of reference for other organizations worldwide. AERB regulates the radiation facilities in India; therefore, most set-ups follow their safety standards and instructions.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] High-dose versus low-dose rate brachytherapy in definitive radiotherapy of cervical cancer
    Kucera, H
    Pötter, R
    Knocke, TH
    Baldass, M
    Kucera, E
    WIENER KLINISCHE WOCHENSCHRIFT, 2001, 113 (1-2) : 58 - 62
  • [42] INNOVATIVE TECHNICS IN RADIATION ONCOLOGY - INTRAOPERATIVE RADIOTHERAPY - HIGH-DOSE RATE BRACHYTHERAPY
    GERARD, JP
    ROMESTAING, P
    ARDIET, JM
    MARQUIS, I
    ROCHER, F
    SENTENAC, I
    PATHOLOGIE BIOLOGIE, 1993, 41 (01): : 71 - 72
  • [43] Towards Steering a High-Dose Rate Brachytherapy Needle With a Robotic Steerable Stylet
    Deaton, Nancy J. J.
    Brumfiel, Timothy A. A.
    Sheft, Maxina K.
    Yamamoto, Kent K. K.
    Elliott, Drew
    Patel, Pretesh
    Desai, Jaydev P. P.
    IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS, 2023, 5 (01): : 54 - 65
  • [44] An Inter-Fraction Adaptive Strategy for High-Dose Rate Prostate Brachytherapy
    Pouliot, J.
    Foster, W.
    Cunha, A. J.
    Hsu, I-C
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] Perioperative fractionated high-dose rate brachytherapy in the treatment of soft tissue sarcomas
    Petera, J
    Neumanová, R
    Odrázka, K
    Ondrák, M
    Soumarová, R
    Zaloudík, J
    Janícek, P
    Procházka, E
    Kohlová, T
    NEOPLASMA, 2004, 51 (01) : 59 - 63
  • [46] Factors affecting the dosimetry of high-dose rate intracavitary brachytherapy in cervical cancer
    Mahapatra, Bikash Ranjan
    Barik, Sandip Kumar
    Das, Deepak Kumar
    Das Majumdar, Saroj Kumar
    Parida, Dillip Kumar
    Ramasubbu, Mathan Kumar
    Badajena, Avinash
    Barik, Bijay Kumar
    Mishra, Minakshi
    Pattanaik, Ashutosh
    Kanungo, Satyabrata
    Muraleedharan, Anupam
    Ahmed, Sk Soel
    Mukherjee, Priyanka
    Abdulla, Shaha Sheik
    Mahajan, Ankur
    Sarkar, Arnab
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [47] Adjuvant high-dose rate (HDR) brachytherapy for ocular tumours with orbital invasion
    Pagliara, Monica Maria
    Tagliaferri, Luca
    Lanza, Angela
    Azario, Luigi
    Savino, Gustavo
    Autorino, Rosa
    Scupola, Andrea
    Valentini, Vincenzo
    Blasi, Maria Antonietta
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [48] The relationship between dose heterogeneity ("hot" spots) and complications following high-dose rate brachytherapy
    Vikram, B
    Deore, S
    Beitler, JJ
    Sood, B
    Mullokandov, E
    Kapulsky, A
    Fontenla, DP
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 983 - 987
  • [50] DOSIMETRIC IMPACT OF INTERFRACTION CATHETER MOVEMENT IN HIGH-DOSE RATE PROSTATE BRACHYTHERAPY
    Foster, William
    Cunha, J. Adam M.
    Hsu, I-Chow
    Weinberg, Vivan
    Krishnamurthy, Devan
    Pouliot, Jean
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (01): : 85 - 90