Experimental research on the microclimate in the naturally ventilated multi-span greenhouse

被引:0
|
作者
Gao, Zhenjun [1 ]
Li, Wenyang [1 ]
Li, Wei [2 ]
Ding, Xiaoming [3 ]
机构
[1] China Three Gorges Univ, Coll Mech & Power Engn, Yichang 443002, Hubei, Peoples R China
[2] Guangdong Modern Agr Equipment Res Inst, Guangzhou 510630, Peoples R China
[3] Acad Agr Planning & Engn, Minist Agr & Rural Affairs, Key Lab Agr Facil Struct Engn, Beijing 100125, Peoples R China
关键词
natural ventilation; multi-span greenhouse; environmental factors; microclimate; PERFORMANCE;
D O I
10.25165/j.ijabe.20241703.7073
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
In order to further understand the changing laws of environmental factors in large multi-span greenhouses under natural ventilation conditions and the internal relations between various environmental factors, and ultimately improve the precision of microclimate regulation of large multi-span greenhouses. Taking the multi-span greenhouse with a small spire structure in the Demonstration Base of Guangdong Agricultural Technology Extension Station as the research object, under the condition of natural ventilation with butterfly-shaped windows, the changes in temperature, humidity, wind speed and solar light intensity of different monitoring planes in the greenhouse were monitored. After analyzing the monitoring data, it was found that: 1) The temperature gradient in the vertical direction in the large multi-span greenhouse is more obvious than that in the small greenhouse, and the highest average temperature difference monitored can reach 7.9 degrees C. The velocity field in the multispan greenhouse is always maintained within the range of 0.3-0.4 m/s, and the ambient wind speed has no effect on the airflow speed in the greenhouse. The humidity and speed in the multi-span greenhouse show good uniformity. 2) In a large multi-span greenhouse, the secondary radiation generated by the internal shading has less impact on the area near the ground, which can effectively reduce the ground temperature. 3) Under the conditions studied in this research, the temperature and humidity in the greenhouse follow the external environment as well, showing that the greenhouse design is reasonable, and the air renewal and heat exchange inside and outside the greenhouse are good during natural ventilation.
引用
收藏
页码:68 / 74
页数:7
相关论文
共 50 条
  • [41] Two-dimensional numerical simulation of natural ventilation tn a multi-span greenhouse
    Lee, IB
    Short, TH
    TRANSACTIONS OF THE ASAE, 2000, 43 (03): : 745 - 753
  • [42] Development of a microclimate model for prediction of temperatures inside a naturally ventilated greenhouse under cucumber crop in soilless media
    Singh, Mahesh Chand
    Singh, J. P.
    Singh, K. G.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2018, 154 : 227 - 238
  • [43] Experimental investigations of a multi-span flexible structure subjected to moving masses
    Stancioiu, Dan
    Ouyang, Huajiang
    Mottershead, John E.
    James, Simon
    JOURNAL OF SOUND AND VIBRATION, 2011, 330 (09) : 2004 - 2016
  • [44] Experimental investigation of multi-span post-tensioned glass beams
    Cupać J.
    Martens K.
    Nussbaumer A.
    Belis J.
    Louter C.
    Glass Structures & Engineering, 2017, 2 (1) : 3 - 15
  • [45] Experimental study of ambient temperature and humidity distribution in large multi-span greenhouse based on different crop heights and ventilation conditions
    Mao, Qianjun
    Li, Hongwei
    Ji, Chenchen
    Peng, You
    Li, Tao
    APPLIED THERMAL ENGINEERING, 2024, 248
  • [46] Effects of ventilator configuration on the flow pattern of a naturally-ventilated three-span Mediterranean greenhouse
    Espinoza, Karlos
    Lopez, Alejandro
    Valera, Diego L.
    Molina-Aiz, Francisco D.
    Torres, Jose A.
    Pena, Araceli
    BIOSYSTEMS ENGINEERING, 2017, 164 : 13 - 30
  • [47] Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facade
    Andelkovic, Aleksandar S.
    Gvozdenac-Urosevic, Branka
    Kljajic, Miroslav
    Ignjatovic, Marko G.
    ENERGY AND BUILDINGS, 2015, 86 : 766 - 781
  • [48] Naturally ventilated greenhouse designs for optimum cooling
    Short, TH
    Lee, I
    Stowell, RR
    PROCEEDINGS OF THE FIFTH INTERNATIONAL SYMPOSIUM ON PROTECTED CULTIVATION IN MILD WINTER CLIMATES: CURRENT TRENDS FOR SUSTAINABLE TECHNOLOGIES, VOLS I AND II, 2001, (559): : 177 - 182
  • [49] Effectiveness of horizontal air flow fans supporting natural ventilation in a Mediterranean multi-span greenhouse
    Lopez, Alejandro
    Luis Valera, Diego
    Domingo Molina-Aiz, Francisco
    Pena, Araceli
    SCIENTIA AGRICOLA, 2013, 70 (04): : 219 - 228
  • [50] Vibration analysis of a multi-span beam
    Wang, Rong-Tyai
    Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao, 1994, 15 (01): : 88 - 93