Experimental study of ambient temperature and humidity distribution in large multi-span greenhouse based on different crop heights and ventilation conditions

被引:5
|
作者
Mao, Qianjun [1 ]
Li, Hongwei [1 ]
Ji, Chenchen [1 ]
Peng, You [1 ]
Li, Tao [1 ]
机构
[1] Wuhan Univ Sci & Technol, Sch Urban Construction, Wuhan 430065, Peoples R China
基金
中国国家自然科学基金;
关键词
Multi -span greenhouse; Field test; Crop height; Spatial distribution of temperature; Ventilation condition; DRIVEN NATURAL VENTILATION; SOLAR GREENHOUSE; THERMAL PERFORMANCE; MICROCLIMATE; SIMULATION; TRANSPIRATION; SYSTEM; MODEL; HEAT;
D O I
10.1016/j.applthermaleng.2024.123176
中图分类号
O414.1 [热力学];
学科分类号
摘要
Analyzing the distribution of temperature and humidity within a greenhouse is essential for optimizing ventilation strategies and improving crop quality and yield. The temperature and humidity distribution of eight -span greenhouse under natural ventilation and mechanical ventilation is studied experimentally. The influence of different crop height on temperature and humidity distribution in greenhouse and the influence of different mechanical ventilation strategies on temperature regulation were discussed. The results showed that the temperature difference between inside and outside the greenhouse decreased with the increase of crop height. Under natural ventilation conditions, the soil surface temperature is the highest, and the temperature at 0.5 m above the surface is the lowest, with the maximum temperature difference of 0.9 degrees C. The temperature in the greenhouse was higher in the west and lower in the east, and the temperature difference decreased with the increase of crop height. In the east - west direction, the maximum temperature difference between tall crops, short crops and nonplanted crops was 0.7 degrees C, 0.9 degrees C and 1.0 degrees C, respectively. High crops increase the relative humidity in the greenhouse and increase the uneven distribution of relative humidity. When growing tall crops, the difference between indoor and outdoor relative humidity is only 2.3 %. When the external shade and fan are turned on at the same time, the cooling effect is the best, the energy consumption is lower, and the temperature distribution is the most uniform. The results provide a valuable reference for optimizing greenhouse structure, formulating ventilation strategy and reducing agricultural energy consumption.
引用
收藏
页数:18
相关论文
共 18 条
  • [1] Simulation of ambient temperature and humidity distribution in eight-span greenhouse under different wind conditions and corn height
    Mao, Qianjun
    Li, Hongwei
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [2] CFD-based Simulation of the Temperature Distribution in Multi-span Greenhouse with Warm Air Heating System
    Ji, Hengsong
    Wang, Qian
    Guo, Zeyu
    ENERGY ENGINEERING AND ENVIRONMENTAL ENGINEERING, PTS 1AND 2, 2013, 316-317 : 1138 - +
  • [3] Lee-side ventilation-induced air movement in a large-scale multi-span greenhouse
    Wang, S
    Deltour, J
    JOURNAL OF AGRICULTURAL ENGINEERING RESEARCH, 1999, 74 (01): : 103 - 110
  • [4] Analysis and Optimization of Greenhouse Gutter Effect on Radiation Distribution inside Multi-span Greenhouses Based on Dynamic Model
    Zhou B.
    Sun W.
    Guo W.
    Zhou B.
    Shi L.
    Li G.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2021, 52 (05): : 286 - 292
  • [5] Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen
    Liu S.-Z.
    He Y.
    Zhang Y.-B.
    Miao X.-W.
    Journal of Zhejiang University-SCIENCE B, 2005, 6 (6): : 523 - 529
  • [6] Prediction and analysis model of temperature and its application to a natural ventilation multi-span plastic greenhouse equipped with insect-proof screen
    刘淑珍
    何勇
    张玉宝
    苗香雯
    JournalofZhejiangUniversityScience, 2005, (06) : 523 - 529
  • [7] A wind tunnel study of natural ventilation for multi-span greenhouse scale models using two-dimensional particle image velocimetry (PIV)
    Lee, I
    Sase, S
    Okushima, L
    Ikeguchi, A
    Choi, K
    Yun, J
    TRANSACTIONS OF THE ASAE, 2003, 46 (03): : 763 - 772
  • [8] Mitigation of the seismic response of multi-span bridges using MR dampers: Experimental study of a new SMC-based controller
    El-Khoury, Omar
    Kim, Chung
    Shafieezadeh, Abdollah
    Hur, Jee Eun
    Heo, Gwang Hee
    JOURNAL OF VIBRATION AND CONTROL, 2018, 24 (01) : 83 - 99
  • [9] Experimental study on smoke temperature distribution under different power conditions in utility tunnel
    Zhao, Yong-chang
    Zhu, Guo-qing
    Gao, Yun-ji
    CASE STUDIES IN THERMAL ENGINEERING, 2018, 12 : 69 - 76
  • [10] Experimental Study of Temperature Profile in Underground Corridor of Different Ventilation Conditions Induced by Fire in an Adjacent Compartment
    State Key Laboratory of Fire Science, University of Science and Technology of China, Anhui, Hefei, China
    不详
    不详
    1600,