Comparison of Glaucoma Detection Performance of Binocular Perimetry Screening Program Using imo Perimetry With Frequency Doubling Technology

被引:0
|
作者
Nishijima, Euido [1 ]
Hosaka, Daisuke [1 ,2 ]
Ogawa, Shumpei [1 ,3 ]
Itoh, Yoshinori [1 ]
Noro, Takahiko [1 ]
Okude, Sachiyo [1 ]
Sano, Kei [1 ]
Yoshikawa, Keiji [1 ,4 ]
Tatemichi, Masayuki [5 ]
Nakano, Tadashi [1 ]
机构
[1] Jikei Univ, Dept Ophthalmol, Sch Med, 3-25-8 Nishi Shimbashi,Minato Ku, Tokyo 1058461, Japan
[2] Machida Municipal Hosp, Dept Ophthalmol, Tokyo, Japan
[3] Atsugi City Hosp, Dept Ophthalmol, Atsugi, Kanagawa, Japan
[4] Yoshikawa Eye Clin, Tokyo, Japan
[5] Tokai Univ, Dept Prevent Med, Sch Med, Isehara, Japan
来源
基金
日本学术振兴会;
关键词
screening; visual field; imo perimetry; glaucoma; RISK-FACTORS; PREVALENCE; BURDEN;
D O I
10.1167/tvst.13.8.9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: We aimed to preliminarily compare the glaucoma detection accuracy of a head-mounted binocular visual perimeter "imo" screening program (ISP) with that of frequency doubling technology (FDT). Methods: This multicenter, diagnostic accuracy study based on prospectively collected data included 76 non-glaucoma (including pre-perimetric glaucoma) eyes and 92 glaucomatous eyes from patients visiting two hospitals. Patients underwent ISP and FDT (C-20-1 screening program) on the same day. Diagnostic efficacy was evaluated using receiver operating characteristic curves and areas under the curve (AUCs). In addition, we compared the ISP and FDT testing times. Results: AUC values for ISP versus FDT were as follows: (1) mild-stage glaucoma (mean deviation [MD] > -6 dB), 0.82 (95% confidence interval [CI], 0.75-0.88) versus 0.76 (95% CI, 0.68-0.83); moderate-stage glaucoma (-6 dB >= MD >= -12 dB), 0.98 (95% CI, 0.95- 1.00) versus 0.96(95% CI, 0.93-1.00); and advanced-stage glaucoma (-12 dB > MD), 1.00 (95% CI, 1.00-1.00) versus 0.99(95% CI, 0.98-1.00). In addition, mild-stage glaucoma was classified into two stages (MD > -3 D) and (-3 D >= MD > -6 D). AUC values were 0.81 (95% CI, 0.73-0.88) versus 0.76 (95% CI, 0.68-0.84) for MD > -3 D and 0.86 (95% CI, 0.77- 0.94) versus 0.73 (95% CI, 0.61-0.86) for -3 D >= MD > -6 D. The testing time for the ISP was significantly shorter than that of FDT for all glaucoma stages (P < 0.001). Conclusions: The ISP demonstrates non-inferiority in detecting glaucoma and has a shorter testing time compared with FDT. These findings provide evidence for applied further studies on large-scale population-based glaucoma screening. Translational Relevance: Our study provides a non-inferior and quicker glaucoma screening than existing tools.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Prospective and randomized comparison of frequency doubling perimetry vs standard automated perimetry in patients with glaucoma
    Kampmeier, J
    Eisert, B
    Buchwald, HJ
    Lang, GK
    Lang, GE
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (03) : 157 - 167
  • [32] Is reading disability likely to interfere with glaucoma screening of adults using frequency-doubling technology perimetry?
    Edwards, JD
    De Leon-Ortega, J
    Bearden, WH
    Rumble, ME
    Girkin, CA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (06) : 816 - 820
  • [33] Frequency Doubling Technology perimetry and standard automated perimetry in migraine
    Harle, DE
    Evans, BJW
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 233 - 239
  • [34] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [35] New techniques: frequency doubling technology perimetry, objective perimetry and flicker and motion perimetry
    Brusini, P
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 : 20 - 20
  • [36] Relationship of SITA and full-threshold standard perimetry to frequency-doubling technology perimetry in glaucoma
    Boden, C
    Pascual, J
    Medeiros, FA
    Aihara, M
    Weinreb, RN
    Sample, PA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (07) : 2433 - 2439
  • [37] Effect of cataract extraction on frequency doubling technology perimetry in patients with glaucoma
    Siddiqui, MAR
    Azuara-Blanco, A
    Neville, S
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (12) : 1569 - 1571
  • [38] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69
  • [39] Screening for glaucoma with frequency doubling perimetry and Heidelberg Retina Tomograph.
    Andrada, MT
    Antón, A
    Villegas, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S293 - S293
  • [40] Screening for Patients with Mild Alzheimer Disease Using Frequency Doubling Technology Perimetry
    Aykan, Umit
    Akdemir, M. Orcun
    Yildirim, Ozlem
    Varlibas, Figen
    NEURO-OPHTHALMOLOGY, 2013, 37 (06) : 239 - 246