Influence of torque and bone type on stability quotient of two implant platforms: a clinical trial

被引:0
|
作者
Bannwart, Lisiane Cristina [1 ]
dos Santos, Daniela Micheline [1 ]
Souza, Joao Paulo do Vale [1 ]
Neto, Clovis Lamartine de Moraes M. E. L. O. [1 ]
da Silva, Emily Vivianne Freitas [2 ]
Mazaro, Jose Vitor Quinelli [1 ]
Salzedas, Leda Maria Piscinini [3 ]
Goiato, Marcelo Coelho [1 ]
机构
[1] Univ Estadual Paulista Unesp, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Prosthodont, Sao Paulo, SP, Brazil
[3] Univ Estadual Paulista Unesp, Aracatuba Dent Sch, Dept Diag & Surg, Aracatuba, SP, Brazil
来源
BRAZILIAN ORAL RESEARCH | 2024年 / 38卷
关键词
Dental Implants; Cortical Bone; Torque; Alveolar Bone Loss; DENTAL IMPLANTS; DETERMINANTS;
D O I
10.1590/1807-3107bor-2024.vol38.0049
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography. A significant difference was noted in the ISQ values between t1 and t2 in type III bone for EH and MT implants. No significant difference in bone loss values was observed when comparing bone types for EH or MT in all evaluated sites. Based on marginal bone loss assessed using radiography, there was no significant difference between the MT and EH groups. A positive correlation between torque and ISQ t1 value was observed for MT (correlation: 0.439; p = 0.041) and EH (correlation: 0.461; p = 0.031) implants. For EH and MT implants, the greater the insertion torque, the greater was the ISQ value (moderately positive correlation). A weak negative correlation was found between bone type and ISQ t1 for MT implants. Contrarily, no correlation was observed between bone type and ISQ t1 for EH implants. In all cases, bone loss around the implants was clinically normal.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Comparative evaluation of implant stability quotient trends, crestal bone loss and survival of photofunctionalised and untreated dental implants: A split-mouth randomised controlled clinical trial
    Sandhu, Ramandeep
    Kheur, Mohit
    Lakha, Tabrez
    Kheur, Supriya
    Le, Bach
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2021, 14 (02) : 127 - 138
  • [32] In Vitro Investigation of the Dependency Between Abutment Length and Implant Stability Quotient (ISQ) for Stability Measurements on Bone Anchored Hearing Implant Systems
    Hogsbro, Morten
    Agger, Andreas
    Johansen, Lars Vendelbo
    Gaihede, Michael
    OTOLOGY & NEUROTOLOGY, 2020, 41 (06) : 848 - 854
  • [33] Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial
    Valderrama, Pilar
    Oates, Thomas W.
    Jones, Archie A.
    Simpson, James
    Schoolfield, John D.
    Cochran, David L.
    JOURNAL OF PERIODONTOLOGY, 2007, 78 (02) : 262 - 272
  • [34] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [35] Effectiveness of Photobiomodulation With Low-Level Laser Therapy on the Implant Stability Quotient at Different Time Intervals: A Randomized Clinical Trial
    Shenoy, Amrutha
    Ganapathy, Dhanraj
    Maiti, Subhabrata
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [36] Evaluation of the insertion torque, implant stability quotient and drilled hole quality for different drill design: an invitro Investigation
    Alexandre Gehrke, Sergio
    Calvo Guirado, Jose Luis
    Bettach, Raphael
    Del Fabbro, Massimo
    Perez-Albacete Martinez, Carlos
    Shibli, Jamil Awad
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (06) : 656 - 662
  • [37] Stability of guided bone regeneration with two ratios of biphasic calcium phosphate at implant sites in the esthetic zone: A randomized controlled clinical trial
    Arunjaroensuk, Sirida
    Thunyakitpisal, Pasutha
    Nampuksa, Katanchalee
    Monmaturapoj, Naruporn
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (08) : 850 - 862
  • [38] Diagnostic accuracy of the implant stability quotient in monitoring progressive peri-implant bone loss: An experimental study in dogs
    Monje, Alberto
    Insua, Angel
    Monje, Florencio
    Munoz, Fernando
    Salvi, Giovanni E.
    Buser, Daniel
    Chappuis, Vivianne
    CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 (10) : 1016 - 1024
  • [39] Influence of cortical bone thickness and implant length on implant stability at the time of surgery - clinical, prospective, biomechanical, and imaging study
    Miyamoto, I
    Tsuboi, Y
    Wada, E
    Suwa, H
    Iizuka, T
    BONE, 2005, 37 (06) : 776 - 780
  • [40] Influence of titanium and titanium-zirconium alloy as implant materials on implant stability of maxillary implant retained overdenture: a randomized clinical trial
    Abd El-Hady, Amany Ibrahim
    Eid, Hany Ibrahim
    Mohamed, Shaimaa Lotfy
    Fadl, Sawsan Maged
    BMC ORAL HEALTH, 2024, 24 (01):