Influence of torque and bone type on stability quotient of two implant platforms: a clinical trial

被引:0
|
作者
Bannwart, Lisiane Cristina [1 ]
dos Santos, Daniela Micheline [1 ]
Souza, Joao Paulo do Vale [1 ]
Neto, Clovis Lamartine de Moraes M. E. L. O. [1 ]
da Silva, Emily Vivianne Freitas [2 ]
Mazaro, Jose Vitor Quinelli [1 ]
Salzedas, Leda Maria Piscinini [3 ]
Goiato, Marcelo Coelho [1 ]
机构
[1] Univ Estadual Paulista Unesp, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Aracatuba, SP, Brazil
[2] Univ Sao Paulo, Sch Dent, Dept Prosthodont, Sao Paulo, SP, Brazil
[3] Univ Estadual Paulista Unesp, Aracatuba Dent Sch, Dept Diag & Surg, Aracatuba, SP, Brazil
来源
BRAZILIAN ORAL RESEARCH | 2024年 / 38卷
关键词
Dental Implants; Cortical Bone; Torque; Alveolar Bone Loss; DENTAL IMPLANTS; DETERMINANTS;
D O I
10.1590/1807-3107bor-2024.vol38.0049
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this study was to analyze the influence of insertion torque, bone type, and peri-implant bone loss on implant stability quotient (ISQ) of cylindrical external hexagon (EH) and Morse Taper (MT) implants. Forty-four single implants were placed in the edentulous areas of 20 patients who met the inclusion and exclusion criteria. Immediately after implant placement (t1) and after osseointegration (four and six months for mandible and maxilla, respectively) (t2), insertion torque, resonance frequency, and peri-implant bone loss were measured using probing depths and digital periapical radiography. A significant difference was noted in the ISQ values between t1 and t2 in type III bone for EH and MT implants. No significant difference in bone loss values was observed when comparing bone types for EH or MT in all evaluated sites. Based on marginal bone loss assessed using radiography, there was no significant difference between the MT and EH groups. A positive correlation between torque and ISQ t1 value was observed for MT (correlation: 0.439; p = 0.041) and EH (correlation: 0.461; p = 0.031) implants. For EH and MT implants, the greater the insertion torque, the greater was the ISQ value (moderately positive correlation). A weak negative correlation was found between bone type and ISQ t1 for MT implants. Contrarily, no correlation was observed between bone type and ISQ t1 for EH implants. In all cases, bone loss around the implants was clinically normal.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Effect of photobiomodulation therapy of overprepared dental implant bed on torque removal and implant stability quotient: an experimental study in sheep
    Xailani, Kocher K.
    Hamad, Shehab A.
    MINERVA DENTAL AND ORAL SCIENCE, 2024, 73 (02) : 96 - 101
  • [22] In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems
    Andres-Garcia, Rodrigo
    Garcia Vives, Nuria
    Herrero Climent, Federico
    Fernandez Palacin, Ana
    Rios Santos, Vicente
    Herrero Climent, Mariano
    Bullon, Pedro
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2009, 14 (02): : E93 - E97
  • [23] Influence of peri-implant bone quality on implant stability
    Schiuma, Damiano
    Plecko, Michael
    Kloub, Martin
    Rothstock, Stephan
    Windolf, Markus
    Gueorguiev, Boyko
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 82 - 87
  • [24] The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog
    Manresa, Carolina
    Bosch, Manel
    Echeverria, Jose J.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (11) : 1213 - 1221
  • [25] Effect of Different Crown Removing Procedures on the Implant Stability Quotient and Removal Torque Values of Dental Implants
    Akin, Hakan
    Unal, Yasemen
    Yilmazer, Kaan
    CLINICAL AND EXPERIMENTAL HEALTH SCIENCES, 2021, 11 (02): : 314 - +
  • [26] The Effects of Defect Type and Depth, and Measurement Direction on the Implant Stability Quotient Value
    Shin, Seung-Yun
    Shin, Seung-Il
    Kye, Seung-Beom
    Hong, Jongrak
    Paeng, Jun-Young
    Chang, Seok-Woo
    Yang, Seung-Min
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (06) : 652 - 656
  • [27] Clinical efficacy of two vertical soft tissue augmentation techniques for peri-implant crestal bone level stability: A randomized clinical trial
    Puisys, Algirdas
    Vindasiute-Narbute, Egle
    Razukevicius, Dainius
    Akhondi, Samuel
    Gallucci, German O.
    Pedrinaci, Ignacio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024,
  • [28] The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
    Park, In-Phill
    Kim, Seong-Kyun
    Lee, Shin-Jae
    Lee, Joo-Hee
    JOURNAL OF ADVANCED PROSTHODONTICS, 2011, 3 (02): : 76 - 80
  • [29] Relation between initial implant stability quotient and bone-implant contact percentage: an in vitro model study
    Huang, Heng-Li
    Tsai, Ming-Tzu
    Su, Kuo-Chih
    Li, Yu-Fen
    Hsu, Jui-Ting
    Chang, Chih-Han
    Fuh, Lih-Jyh
    Wu, Aaron Yu-Jen
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (05): : E356 - E361
  • [30] Investigation of Implant Stability Quotient Values of Dental Implants Placed in Vascularized Bone Grafts
    Matsumoto, Keisuke
    Mano, Takamitsu
    Inoue, Kazuya
    Yamamoto, Kayoko
    Imagawa, Naoko
    Takahashi, Ayaka
    Ueno, Takaaki
    JOURNAL OF HARD TISSUE BIOLOGY, 2022, 31 (01) : 55 - 58