Suppression of Optical Frequency Shift Based on Single-Beam Compact SERF Atomic Magnetometer

被引:0
|
作者
Miao, Kexuan [1 ,2 ,3 ]
Hu, Tao [1 ,2 ,3 ,4 ]
Guo, Qingqian [1 ,2 ,3 ]
Feng, Xiaoyu [3 ]
Zhang, Yin [1 ,2 ,3 ]
Chang, Yan [1 ,2 ,3 ]
Yang, Xiaodong [1 ,2 ,3 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Div Life Sci & Med, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, Med Imaging Dept, Suzhou 215163, Jiangsu, Peoples R China
[3] Jihua Lab, Foshan 528200, Guangdong, Peoples R China
[4] Jinan Guoke Med Technol Dev Co Ltd, Jinan 250102, Shandong, Peoples R China
来源
关键词
medical optics; atomic magnetometer; spin-exchange relaxation free; optical frequency shift; fictitious magnetic field; orthogonality;
D O I
10.3788/CJL240503
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Objective With advancements in quantum manipulation and optoelectronic detection technologies, the atomic magnetometer, a novel quantum extremely- weak magnetic sensor, has experienced rapid development. Operating in the spin exchange relaxation free (SERF) state, atomic magnetometers offer numerous advantages, including non- cryogenic operation, compact structure, low maintenance costs, and high sensitivity, making them widely applicable in various fields. However, the phenomenon of optical frequency shift, induced by off- resonant circularly polarized pumping light, critically affects the orthogonality of measurement and output response in SERF atomic magnetometers. This study proposes a method for suppressing optical frequency shift based on the analysis of the non- sensitive axis response using a self-made compact single- beam SERF 87 Rb atomic magnetometer. The curve of optical frequency shift, combined with the curve of light absorption, is precisely plotted and analyzed to determine the central resonant frequency of the SERF atomic magnetometer. The analysis indicates that employing this suppression method significantly reduces coupling crosstalk between the measurement axes of the magnetometer, thereby enhancing the orthogonality and output response of the sensitive axis. Experimental results validate the effectiveness of this suppression method. Further comparison reveals that the performance of the self-made compact SERF atomic magnetometer is enhanced by suppressing optical frequency shift, resulting in a sensitivity of 13 fT/root Hz within a bandwidth of 140 Hz and a dynamic range of approximately +/- 3 nT. Methods The optical frequency shift direction is regarded as the photon spin direction, which is equivalent to the existence of an equivalent virtual magnetic field in the direction of the pumping light (x-axis). Due to this fictitious magnetic field, the sensitive axis (z-axis) of the SERF atomic magnetometer reacts to signals from the non- sensitive axis (y-axis). Applying a weak oscillating magnetic field at 40 Hz to the y-axis and a direct current compensation magnetic field to the x-axis reveals a trend where the response of the y- axis varies with the compensation magnetic field along the x-axis. When the response of the y-axis reaches its minimum value, it indicates completion of compensation for the fictitious magnetic field. Results and Discussions As a result of the suppression method, the response of the 40 Hz signal from the y-axis notably decreases (Fig. 2) after compensating for the magnetic field along the x-axis. The variation curve of the compensation magnetic field applied along the x-axis with the laser frequency (Fig. 3) indicates that the magnetic field along the x-axis mainly consists of the fictitious magnetic field of optical frequency shift due to the constant residual magnetic field. After analyzing and compensating for the residual magnetic field along the x-axis, approximately 0.2 nT, based on the principle of optical frequency shift, the optical frequency shift curve [Fig. 4(a)] is plotted, confirming its existence. Coupled with the light absorption curve [Fig. 4(b)], the resonant frequency of 87 Rb atoms is determined to be 377109.23 GHz. By optical frequency shift suppression, the measured coupling coefficient is about 4.5%, which can be used to evaluate more accurately the orthogonality between the measured axes and the response of the sensitive axis(Fig. 5). With potential coupling crosstalk between the y and z axes accurately eliminated, the response of the z-axis significantly improves after optical frequency shift suppression (Fig. 6). As a result of this operation, the self-made compact fiber- coupled SERF atomic magnetometer achieves high sensitivity of 13 fT/ Hz within a-3 dB bandwidth of 140 Hz, and its dynamic range is approximately +/- 3 nT. Conclusions This study proposes a method for suppressing optical frequency shift based on analyzing the response of the non- sensitive axis using a self-made single- beam compact SERF Rb atomic magnetometer. By utilizing the proposed suppression method, the phenomenon of optical frequency shift and the existence of its equivalent fictitious magnetic field are verified. The central resonant frequency of the SERF atomic magnetometer is determined from the plotted curves of optical frequency shift and light absorption. Moreover, suppressing optical frequency shift significantly enhances the orthogonality between measurement axes, reduces crosstalk,and improves the response of the sensitive axis of the SERF atomic magnetometer, thus demonstrating the efficacy of the suppression method. The study results indicate that after suppressing optical frequency shift, the bandwidth, sensitivity, dynamic range, and other performance indicators of the self-made SERF atomic magnetometer improve. Its sensitivity can maintain a level of 13 fT/ Hz within a bandwidth of 140 Hz, with a dynamic range of approximately +/- 3 nT.
引用
收藏
页码:15074011 / 15074019
页数:9
相关论文
共 50 条
  • [21] The suppression of the probe laser pumping effect in SERF atomic magnetometer
    Cao, Qian
    Zhai, Yueyang
    Huang, Binyue
    Li, Renjie
    Li, Jiajie
    FRONTIERS IN PHYSICS, 2023, 11
  • [22] Chip Scale Atomic Magnetometer Based on SERF
    Song Xing
    Dong Haifeng
    Fang Jiancheng
    2009 4TH IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1 AND 2, 2009, : 231 - 234
  • [23] Single-Beam Vector Atomic Magnetometer with High Dynamic Range Based on Magnetic Field Modulation
    Chen, Junlin
    Jiang, Liwei
    Zhao, Xin
    Liu, Jiali
    Chai, Yanchao
    Tian, Mengnan
    Lu, Zhenglong
    ADVANCED QUANTUM TECHNOLOGIES, 2024, 7 (12)
  • [24] Single-Beam Miniaturized Atomic Magnetometer With Square-Wave Modulation for Magnetoencephalography
    Ding, Zhongya
    Han, Bangcheng
    Tang, Junjian
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [25] Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer
    Lu, Fei
    Wang, Shuying
    Xu, Nuozhou
    Li, Bo
    Lu, Jixi
    Han, Bangcheng
    PHOTONICS, 2022, 9 (11)
  • [26] Suppression of thermal coupling noise in the SERF atomic co-magnetometer
    Ruan, Jiasen
    Duan, Lihong
    Fu, Yang
    Yang, Lv
    Fan, Wenfeng
    Zhou, Xinxiu
    Quan, Wei
    RESULTS IN PHYSICS, 2023, 53
  • [27] Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
    Chen, Yao
    Zhao, Libo
    Zhang, Ning
    Yu, Mingzhi
    Ma, Yintao
    Han, Xiangguang
    Zhao, Man
    Lin, Qijing
    Yang, Ping
    Jiang, Zhuangde
    OPTICS EXPRESS, 2022, 30 (10) : 16541 - 16552
  • [28] Performance optimization of a SERF atomic magnetometer based on flat-top light beam
    袁子琪
    唐钧剑
    林树东
    翟跃阳
    Chinese Physics B, 2024, 33 (06) : 341 - 347
  • [29] Performance optimization of a SERF atomic magnetometer based on flat-top light beam
    Yuan, Ziqi
    Tang, Junjian
    Lin, Shudong
    Zhai, Yueyang
    CHINESE PHYSICS B, 2024, 33 (06)
  • [30] Analysis and Optimization of Signal Detection Noise of Single-Beam Modulated Atomic Magnetometer Array
    Suo, Yuchen
    Song, Xinda
    Jia, Le
    Long, Tengyue
    Ye, Mao
    Zhou, Binquan
    IEEE SENSORS JOURNAL, 2022, 22 (19) : 18600 - 18609