Seismic performance of precast concrete shear walls with spiral stirrup restrained grout-anchored lapped reinforcement connection

被引:1
|
作者
Tang, Lei [1 ]
Guo, Zhengxing [1 ]
Zang, Xulei [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Jiulonghu Campus, Nanjing 210096, Peoples R China
关键词
shear walls; precast concrete; grout-anchored reinforcements; spiral stirrup; seismic performance; PLASTIC HINGE LENGTH; BEHAVIOR; BENEFITS;
D O I
10.1177/13694332241276053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low-cycle reversed loading tests and finite element analysis were conducted on one cast-in-place (CIP) shear wall specimen and two precast concrete (PC) shear wall specimens with different configurations of spiral stirrup. By comparing the failure modes, load-carrying capacities, hysteresis behaviours, skeleton curves, deformation capacities, stiffness degradation, plastic hinge distributions, and energy dissipation capacities of the PC specimen and the PIC specimen, the mechanical properties of the PC specimen equivalent to those of the CIP specimen were verified. Both the PC and PIC specimens exhibited bending shear failure, consistent with the ductile failure design requirements of "equivalent to cast-in-place". The peak load capacity of the PC specimen was 3.64% higher than that of the PIC specimen, and the hysteresis curve was as full as that of the CIP specimen. The stiffness degradation performance of the PC specimen was slightly lower than that of the CIP specimen in the cracking stage, but it was comparable to that of the CIP specimen after entering the elastic-plastic stage. During the yielding stage, the maximum difference in energy dissipation performance between the CP specimen and the CIP specimen did not exceed 11.34%. Both the tests and finite element analysis confirmed the effective constraint of spiral stirrup on lap joints. Setting spiral stirrup for the vertical distribution reinforcements on the web had no significant effect on the load-carrying capacity of the PC specimen, but it slightly reduced its ductility and energy dissipation performance, by no more than 6.63%. For economic and safety considerations, it is not recommended to use spiral stirrup in this area.
引用
收藏
页码:2592 / 2608
页数:17
相关论文
共 50 条
  • [31] Experimental study on seismic performance of precast concrete shear walls with limited slip bolted connectors
    Fang Q.
    Qiu H.
    Sun J.
    Jiang H.
    Tang L.
    Dongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Southeast University (Natural Science Edition), 2021, 51 (04): : 559 - 565
  • [32] Effect of Connection Deficiency on Seismic Performance of Precast Concrete Shear Wall-Frame Structures
    Cao, Zijian
    Li, Quanwang
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2019, 13 (3-4)
  • [33] Seismic performance of a new type of precast shear walls with non-connected vertical distributed reinforcement
    Liao, Xiandong
    Zhang, Shiqian
    Cao, Zhiwei
    Xiao, Xuwen
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [34] Cyclic performance of precast concrete shear walls with a mortar-sleeve connection for longitudinal steel bars
    Peng, Yuan-Yuan
    Qian, Jia-Ru
    Wang, Yu-Hang
    MATERIALS AND STRUCTURES, 2016, 49 (06) : 2455 - 2469
  • [35] Research on seismic performance of precast steel-concrete composite tube shear walls with horizontal joint
    Dang, Longji
    Pang, Rui
    Liu, Yuhao
    Wang, Yixiao
    Wang, Lu
    Yang, Jian
    ENGINEERING STRUCTURES, 2022, 250
  • [36] Seismic performance of precast concrete superposed shear walls with CFST end columns subjected to cyclic loading
    Zhang, Feng-Liang
    Wu, Bian
    Zhang, Min
    Liu, Yang
    STRUCTURES, 2024, 68
  • [37] Seismic Performance of Precast Shear Walls Using Fibre-reinforced Recycled Brick Aggregate Concrete
    Huang, Wei
    Zhang, Jiarui
    Sun, Yujiao
    Hu, Gaoxing
    Fan, Zhenhui
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (12) : 3362 - 3390
  • [38] Parametric Studies on Seismic Performance of New Precast Braced Concrete Shear Walls under Cyclic Loading
    Tang, Ya-Chao
    Li, Hong-Nan
    Li, Chao
    JOURNAL OF STRUCTURAL ENGINEERING, 2023, 149 (06)
  • [39] Cyclic loading experiments on seismic performance of precast concrete superposed shear walls with CFST end columns
    Wu, Bian
    Zhang, Feng-Liang
    Zhang, Min
    Li, Yong
    JOURNAL OF BUILDING ENGINEERING, 2024, 96
  • [40] Experimental study on seismic performance of steel-connection precast shear walls with earthquake-damage reparability
    Yan G.-Y.
    Chen Y.-H.
    Wu Y.-X.
    Zhang P.-Q.
    Li J.-H.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2023, 36 (06): : 1579 - 1589