Seismic performance of precast concrete shear walls with spiral stirrup restrained grout-anchored lapped reinforcement connection

被引:1
|
作者
Tang, Lei [1 ]
Guo, Zhengxing [1 ]
Zang, Xulei [1 ]
机构
[1] Southeast Univ, Sch Civil Engn, Jiulonghu Campus, Nanjing 210096, Peoples R China
关键词
shear walls; precast concrete; grout-anchored reinforcements; spiral stirrup; seismic performance; PLASTIC HINGE LENGTH; BEHAVIOR; BENEFITS;
D O I
10.1177/13694332241276053
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Low-cycle reversed loading tests and finite element analysis were conducted on one cast-in-place (CIP) shear wall specimen and two precast concrete (PC) shear wall specimens with different configurations of spiral stirrup. By comparing the failure modes, load-carrying capacities, hysteresis behaviours, skeleton curves, deformation capacities, stiffness degradation, plastic hinge distributions, and energy dissipation capacities of the PC specimen and the PIC specimen, the mechanical properties of the PC specimen equivalent to those of the CIP specimen were verified. Both the PC and PIC specimens exhibited bending shear failure, consistent with the ductile failure design requirements of "equivalent to cast-in-place". The peak load capacity of the PC specimen was 3.64% higher than that of the PIC specimen, and the hysteresis curve was as full as that of the CIP specimen. The stiffness degradation performance of the PC specimen was slightly lower than that of the CIP specimen in the cracking stage, but it was comparable to that of the CIP specimen after entering the elastic-plastic stage. During the yielding stage, the maximum difference in energy dissipation performance between the CP specimen and the CIP specimen did not exceed 11.34%. Both the tests and finite element analysis confirmed the effective constraint of spiral stirrup on lap joints. Setting spiral stirrup for the vertical distribution reinforcements on the web had no significant effect on the load-carrying capacity of the PC specimen, but it slightly reduced its ductility and energy dissipation performance, by no more than 6.63%. For economic and safety considerations, it is not recommended to use spiral stirrup in this area.
引用
收藏
页码:2592 / 2608
页数:17
相关论文
共 50 条
  • [21] Seismic Behavior of Innovative Precast Superimposed Concrete Shear Walls with Spiral Hoop and Bolted Steel Connections
    Wu, Xi
    Wang, Meng-fu
    Liu, Ze-long
    ADVANCES IN CIVIL ENGINEERING, 2021, 2021
  • [22] Experimental study on seismic performance of precast concrete shear walls with joint connecting beam
    Wang, Dun
    Lu, Xilin
    Lu, Wensheng
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (10): : 1 - 11
  • [23] Study of effects of sleeve grouting defects on the seismic performance of precast concrete shear walls
    Xiao, Shun
    Wang, Zhuolin
    Li, Xiangmin
    Harries, Kent A.
    Xu, Qingfeng
    Gao, Rundong
    ENGINEERING STRUCTURES, 2021, 236
  • [24] Experimental study and FEA on seismic performance of new hybrid precast concrete shear walls
    Zhu, Zhangfeng
    Guo, Zhengxing
    Tang, Lei
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2018, 51 (03): : 36 - 43
  • [25] Cyclic performance of precast concrete shear walls with a mortar–sleeve connection for longitudinal steel bars
    Yuan-Yuan Peng
    Jia-Ru Qian
    Yu-Hang Wang
    Materials and Structures, 2016, 49 : 2455 - 2469
  • [26] Experimental study on seismic performance of precast concrete shear walls with treatment of sleeve grouting defects
    Xiao S.
    Li X.
    Xu Q.
    Jiang H.
    Gao R.
    Wang Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2022, 43 (04): : 167 - 176
  • [27] Experimental study on seismic performance of precast concrete shear walls with defective and repaired grouted sleeve
    Xie, Linlin
    Liu, Qiang
    Wang, Xinyu
    Yang, Cantian
    STRUCTURES, 2023, 57
  • [28] Seismic performance of precast lightweight aggregate concrete shear walls with supplementary V-ties
    Yang, Keun-Hyeok
    Mun, Ju-Hyun
    Kim, Sanghee
    Im, Chae-Rim
    Jung, Yeon-Back
    ENGINEERING STRUCTURES, 2023, 297
  • [29] Seismic performance of precast composite shear walls reinforced by concrete-filled steel tubes
    Wu, Liwei
    Tian, Ying
    Su, Youpo
    Chen, Haibin
    ENGINEERING STRUCTURES, 2018, 162 : 72 - 83
  • [30] Experimental study on seismic performance of precast concrete hollow shear walls with large aspect ratios
    Zhang, Weijing
    Yang, Leigang
    Qian, Jiaru
    Ma, Tao
    Zhang, Yingbao
    Zhang, Yuzhao
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2019, 52 (06): : 1 - 13