Numerical and experimental investigation of 12 W/60 K high-efficiency coaxial pulse tube cryocooler

被引:0
|
作者
Li, Yanen [1 ,2 ]
Wang, Nailiang [1 ]
Zhao, Miguang [1 ]
Tang, Qingjun [1 ]
Xun, Yuqiang [1 ]
机构
[1] Chinese Acad Sci, Tech Inst Phys & Chem, Key Lab Technol Space Energy Convers, Beijing, Peoples R China
[2] Univ Chinese Acad Sci, Beijing, Peoples R China
关键词
Pulse tube cryocooler; Infrared detector; 12; W/60; K;
D O I
10.1016/j.cryogenics.2024.103941
中图分类号
O414.1 [热力学];
学科分类号
摘要
Maintaining a low-temperature environment is paramount in pursuing reliable operation for infrared detectors. To address the rising demand for long-wave infrared detectors functioning in low-temperature environments around 60 K, this study investigates the enhanced efficiency of a 60 K coaxial pulse tube cryocooler (PTC) through both simulation analysis and experimental methods. A PTC model was developed using Sage software to optimize parameters such as cold finger size. Analysis of the internal flow field highlighted that variations in cold head temperature, frequency, and input power significantly impact phase angle distribution within the regenerator. Experimental results yielded the same conclusion and confirmed how these critical factors affect the PTC's performance. Through systematic optimization of simulations and experiments, a cooling performance of 12.7 W/60 K was achieved with an input power of 300 W. Furthermore, when the input power of the PTC was 200 W, a cooling capacity of 9.2 W/60 K was achieved, demonstrating a relative Carnot efficiency of 18.3 %.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] 10 K high frequency pulse tube cryocooler with precooling
    Liu, Sixue
    Chen, Liubiao
    Wu, Xianlin
    Zhou, Yuan
    Wang, Junjie
    CRYOGENICS, 2016, 77 : 15 - 19
  • [42] Single-stage high frequency coaxial pulse tube cryocooler with base temperature below 30 K
    Yang, L. W.
    Xun, Y. Q.
    Thummes, G.
    Liang, J. T.
    CRYOGENICS, 2010, 50 (05) : 342 - 346
  • [43] 18.6 K single-stage high frequency multi-bypass coaxial pulse tube cryocooler
    Chen, Liubiao
    Jin, Hai
    Wang, Junjie
    Zhou, Yuan
    Zhu, Wenxiu
    Zhou, Qiang
    CRYOGENICS, 2013, 54 : 54 - 58
  • [44] Numerical Study of a 10 K Two Stage Pulse Tube Cryocooler with Precooling Inside the Pulse Tube
    Pang, Xiaomin
    Wang, Xiaotao
    Dai, Wei
    Hu, Jianyin
    Luo, Ercang
    26TH INTERNATIONAL CRYOGENIC ENGINEERING CONFERENCE & INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2016, 2017, 171
  • [45] EXPERIMENTAL STUDY ON COOLING PERFORMANCE OF A COAXIAL PULSE TUBE CRYOCOOLER FOR A LIQUID XENON DETECTOR
    Haruyama, T.
    Kasami, K.
    Nishitani, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 711 - +
  • [46] Development of a 1 to 5 W at 80 K stirling pulse tube cryocooler
    Hiratsuka, Y
    Kang, YM
    Matsubara, Y
    CRYOCOOLERS 10, 1999, : 149 - 155
  • [47] Experimental investigation of displacer rod diameter effect on pulse tube cryocooler
    Guo, Zhaorui
    Lin, Yuzhe
    Zhu, Shaowei
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 112 : 69 - 73
  • [48] Study on a 10 W/90 K in-line pulse tube cryocooler
    Zhang, Ankuo
    Chen, Xi
    Wu, Yi Nong
    Zhang, Hua
    Yang, Kaixiang
    CRYOGENICS, 2012, 52 (12) : 800 - 804
  • [49] Design and preliminary experimental investigation of a 4 K Stirling-type pulse tube cryocooler with precooling
    Gan, Zhi-hua
    Li, Zhuo-pei
    Chen, Jie
    Dai, Li
    Qiu, Li-min
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2009, 10 (09): : 1277 - 1284
  • [50] 0.2 W@20.6 K single-stage high frequency pulse tube cryocooler
    Chen, Liu-Biao
    Jin, Hai
    Zhu, Wen-Xiu
    Wang, Jun-Jie
    Zhou, Yuan
    Gu, Kai-Xuan
    Ji, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2013, 34 (04): : 587 - 590