Single-stage high frequency coaxial pulse tube cryocooler with base temperature below 30 K

被引:19
|
作者
Yang, L. W. [1 ,2 ]
Xun, Y. Q. [1 ]
Thummes, G. [2 ]
Liang, J. T. [1 ]
机构
[1] CAS, Tech Inst Phys & Chem, Beijing 100080, Peoples R China
[2] Univ Giessen, Inst Appl Phys, D-35392 Giessen, Germany
基金
中国国家自然科学基金;
关键词
High frequency; Pulse tube; Inertance tube; Double-inlet; Nozzle;
D O I
10.1016/j.cryogenics.2010.01.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper introduces two single-stage high frequency coaxial pulse tube cryocoolers (PTCs) with base temperature below 30 K. One has reached the lowest temperature of 26.1 K with an electric power of 250 W. which is the reported lowest temperature for single-stage high frequency PTC without multi-bypass Using nozzle for double-inlet instead of need valves, the second PTC has achieved the temperature of 28.6 K with an electric power of 235 W The analysis result is coinciding with experiments in general. The paper shows the advantage of the cooperated phase adjustment method of inertance tube and double-Inlet, they might be the best choice when low temperature PTC is required. (C) 2010 Elsevier Ltd. All rights reserved
引用
收藏
页码:342 / 346
页数:5
相关论文
共 50 条
  • [1] 30 K single-stage high frequency coaxial pulse tube cryocooler
    Technical Institute of Physics and Chemistry, CAS, Beijing 100190, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2009, 5 (734-736):
  • [2] 18.6 K single-stage high frequency multi-bypass coaxial pulse tube cryocooler
    Chen, Liubiao
    Jin, Hai
    Wang, Junjie
    Zhou, Yuan
    Zhu, Wenxiu
    Zhou, Qiang
    CRYOGENICS, 2013, 54 : 54 - 58
  • [3] Development of a 35 K single-stage coaxial pulse tube cryocooler
    Wang, Nailiang
    Zhao, Miguang
    Lei, Yilin
    Liang, Jingtao
    ADVANCES IN CRYOGENIC ENGINEERING: PROCEEDINGS OF THE CRYOGENIC ENGINEERING CONFERENCE, CEC 2023, 2024, 1301
  • [4] High frequency two-stage pulse tube cryocooler with base temperature below 20 K
    Yang, LW
    Thummes, G
    CRYOGENICS, 2005, 45 (02) : 155 - 159
  • [5] 0.2 W@20.6 K single-stage high frequency pulse tube cryocooler
    Chen, Liu-Biao
    Jin, Hai
    Zhu, Wen-Xiu
    Wang, Jun-Jie
    Zhou, Yuan
    Gu, Kai-Xuan
    Ji, Wei
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2013, 34 (04): : 587 - 590
  • [6] Matching characteristics of single-stage high-frequency pulse tube cryocooler
    Technical Institute of Physics and Chemistry, CAS, Beijing 100080, China
    不详
    Kung Cheng Je Wu Li Hsueh Pao, 2007, SUPPL. 1 (29-32):
  • [7] High frequency single-stage multi-bypass pulse tube cryocooler for 23.8K
    Yang, Junling
    Hou, Xiaofeng
    Yang, Luwei
    Zhou, Yuan
    Zhang, Liang
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 : 1108 - 1113
  • [8] 40 K single-stage coaxial pulse tube cryocoolers
    Dang, Haizheng
    CRYOGENICS, 2012, 52 (4-6) : 216 - 220
  • [9] Investigation of intermediate cooling capacity from a single-stage coaxial pulse tube cryocooler
    Han, Yinan
    Zhang, Ankuo
    Yu, Wenhui
    Xiong, Chao
    APPLIED THERMAL ENGINEERING, 2022, 217
  • [10] High efficiency 40 K single-stage Stirling-type pulse tube cryocooler
    Wu, X. L.
    Chen, L. B.
    Pan, C. Z.
    Cui, C.
    Wang, J. J.
    Zhou, Y.
    ADVANCES IN CRYOGENIC ENGINEERING, 2017, 278