A compact ion source combining electron-impact and thermal ionization for multiple-reflection time-of-flight mass spectrometry

被引:0
|
作者
Yu, Jiajun [1 ]
Mollaebrahimi, Ali [2 ,3 ]
Andrees, Samuel Ayet San [2 ,4 ]
Dickel, Timo [1 ,2 ]
Plass, Wolfgang R. [1 ,2 ]
Wilsenach, Heinrich [2 ,5 ]
Beck, Soenke [2 ]
Ge, Zhuang [1 ]
Geissel, Hans [1 ,2 ]
Hornung, Christine [1 ,2 ]
Jacobs, Andrew [3 ,6 ]
Kripko-Koncz, Gabriella [2 ,7 ]
Kwiatkowski, Anna A. [3 ,8 ]
Narang, Meetika [1 ]
Scheidenberger, Christoph [1 ,2 ,7 ]
Sequeira, Jaden [3 ,6 ]
Walls, Coulter [3 ,9 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[2] Justus Liebig Univ Giessen, Phys Inst 2, D-35390 Giessen, Germany
[3] TRIUMF Canadas Particle Accelerator Ctr, Vancouver, BC V6T2A3, Canada
[4] Inst Fis Corpuscular CSIC UV, Paterna 46980, Valencia, Spain
[5] Tel Aviv Univ, Sch Phys & Astron, IL-6997801 Tel Aviv, Israel
[6] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T1Z4, Canada
[7] GSI Helmholtz Ctr Heavy Ion Res, Helmholtz Res Acad Hesse FAIR HFHF, Campus Giessen, D-35392 Giessen, Germany
[8] Univ Victoria, Dept Phys & Astron, Victoria, BC V8P5C2, Canada
[9] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T2N2, Canada
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 08期
关键词
FACILITY; TITAN;
D O I
10.1063/5.0213443
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact ion source combining electron impact and thermal ionization has been developed and commissioned in two Multiple-Reflection Time-Of-Flight Mass Spectrometer (MR-TOF-MS) setups at the Fragment Separator Ion Catcher at the GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany, and at TRIUMF's Ion Trap for Atomic and Nuclear science at TRIUMF Canada's particle accelerator center, Vancouver, Canada. The ion source is notable for its compact dimensions of 50 mm in height and 68 mm in diameter. The ion source is currently in daily operation at both facilities. Design, simulations, and results of combining ions from thermal and electron-impact ionization of different gases (perfluoropropane and sulfur hexafluoride) are presented in this work. The systematic effects of heating power on the thermal source were studied in detail. The source has demonstrated stable and long-term production of reference ions over a wide mass range for the MR-TOF-MS. This versatile ion source has also been used to optimize and investigate the transport of ions with different chemical reactivity and ionization potentials.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Mass selective blanking in a compact multiple reflection time-of-flight mass spectrometer
    Hohl, M
    Wurz, P
    Scherer, S
    Altwegg, K
    Balsiger, H
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1999, 188 (03) : 189 - 197
  • [22] Desorption/ionization on silicon time-of-flight/time-of-flight mass spectrometry
    Go, EP
    Prenni, JE
    Wei, J
    Jones, A
    Hall, SC
    Witkowska, HE
    Shen, ZX
    Siuzdak, G
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (10) : 2504 - 2506
  • [23] Ion source with magnetic field for time-of-flight mass spectrometry
    V. I. Karataev
    N. N. Aruev
    [J]. Technical Physics Letters, 2011, 37 : 575 - 578
  • [24] Ion Source with Magnetic Field for Time-of-Flight Mass Spectrometry
    Karataev, V. I.
    Aruev, N. N.
    [J]. TECHNICAL PHYSICS LETTERS, 2011, 37 (06) : 575 - 578
  • [25] Femtosecond Ionization Source for Ultrahigh Resolution Time-of-flight Mass Spectrometry
    Huang, W. Ronny
    Li, Xiang
    Yu, Anthony W.
    Brinckerhoff, William A.
    Fahey, Molly
    [J]. 2018 IEEE AEROSPACE CONFERENCE, 2018,
  • [26] Time-of-flight mass spectrometry with a pulsed glow discharge ionization source
    Steiner, RE
    Lewis, CL
    King, FL
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (09) : 1715 - 1721
  • [27] Ion-optical design of a high-performance multiple-reflection time-of-flight mass spectrometer and isobar separator
    Yavor, Mikhail I.
    Plass, Wolfgang R.
    Dickel, Timo
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2015, 381 : 1 - 9
  • [28] Superimposition of a magnetic field around an ion guide for electron ionization time-of-flight mass spectrometry
    Yue, BF
    Lee, ED
    Rockwood, AL
    Lee, ML
    [J]. ANALYTICAL CHEMISTRY, 2005, 77 (13) : 4167 - 4175
  • [29] A linear time-of-flight mass analyzer for thermal ionization cavity mass spectrometry
    Wayne, DM
    Hang, W
    McDaniel, DK
    Fields, RE
    Rios, E
    Majidi, V
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (07) : 1175 - 1194
  • [30] OPERATION AND MASS RESOLUTION OF A TIME-OF-FLIGHT MASS-SPECTROMETER WITH ELECTRON-IMPACT IONIZATION AND RAPID FIELD REVERSAL
    HOLMLID, L