A compact ion source combining electron-impact and thermal ionization for multiple-reflection time-of-flight mass spectrometry

被引:0
|
作者
Yu, Jiajun [1 ]
Mollaebrahimi, Ali [2 ,3 ]
Andrees, Samuel Ayet San [2 ,4 ]
Dickel, Timo [1 ,2 ]
Plass, Wolfgang R. [1 ,2 ]
Wilsenach, Heinrich [2 ,5 ]
Beck, Soenke [2 ]
Ge, Zhuang [1 ]
Geissel, Hans [1 ,2 ]
Hornung, Christine [1 ,2 ]
Jacobs, Andrew [3 ,6 ]
Kripko-Koncz, Gabriella [2 ,7 ]
Kwiatkowski, Anna A. [3 ,8 ]
Narang, Meetika [1 ]
Scheidenberger, Christoph [1 ,2 ,7 ]
Sequeira, Jaden [3 ,6 ]
Walls, Coulter [3 ,9 ]
机构
[1] GSI Helmholtzzentrum Schwerionenforsch, D-64291 Darmstadt, Germany
[2] Justus Liebig Univ Giessen, Phys Inst 2, D-35390 Giessen, Germany
[3] TRIUMF Canadas Particle Accelerator Ctr, Vancouver, BC V6T2A3, Canada
[4] Inst Fis Corpuscular CSIC UV, Paterna 46980, Valencia, Spain
[5] Tel Aviv Univ, Sch Phys & Astron, IL-6997801 Tel Aviv, Israel
[6] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T1Z4, Canada
[7] GSI Helmholtz Ctr Heavy Ion Res, Helmholtz Res Acad Hesse FAIR HFHF, Campus Giessen, D-35392 Giessen, Germany
[8] Univ Victoria, Dept Phys & Astron, Victoria, BC V8P5C2, Canada
[9] Univ Manitoba, Dept Phys & Astron, Winnipeg, MB R3T2N2, Canada
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 08期
关键词
FACILITY; TITAN;
D O I
10.1063/5.0213443
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A compact ion source combining electron impact and thermal ionization has been developed and commissioned in two Multiple-Reflection Time-Of-Flight Mass Spectrometer (MR-TOF-MS) setups at the Fragment Separator Ion Catcher at the GSI Helmholtz Centre for Heavy Ion Research, Darmstadt, Germany, and at TRIUMF's Ion Trap for Atomic and Nuclear science at TRIUMF Canada's particle accelerator center, Vancouver, Canada. The ion source is notable for its compact dimensions of 50 mm in height and 68 mm in diameter. The ion source is currently in daily operation at both facilities. Design, simulations, and results of combining ions from thermal and electron-impact ionization of different gases (perfluoropropane and sulfur hexafluoride) are presented in this work. The systematic effects of heating power on the thermal source were studied in detail. The source has demonstrated stable and long-term production of reference ions over a wide mass range for the MR-TOF-MS. This versatile ion source has also been used to optimize and investigate the transport of ions with different chemical reactivity and ionization potentials.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Multiple-reflection time-of-flight mass spectrometry
    Plass, Wolfgang R.
    Dickel, Timo
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2013, 349 : 134 - 144
  • [2] Multiple-reflection time-of-flight mass spectrometry for in situ applications
    Dickel, T.
    Plass, W. R.
    Lang, J.
    Ebert, J.
    Geissel, H.
    Haettner, E.
    Jesch, C.
    Lippert, W.
    Petrick, M.
    Scheidenberger, C.
    Yavor, M. I.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 317 : 779 - 784
  • [3] Unveiling nuclear isomers through multiple-reflection time-of-flight mass spectrometry
    Dickel, Timo
    Mollaebrahimi, Ali
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2024, 233 (05): : 1181 - 1190
  • [4] AN ELECTRON-IMPACT STORAGE ION-SOURCE FOR TIME-OF-FLIGHT MASS SPECTROMETERS
    GRIX, R
    GRUNER, U
    LI, G
    STROH, H
    WOLLNIK, H
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 93 (03): : 323 - 330
  • [5] PHOTOEMISSION ELECTRON-IMPACT IONIZATION IN TIME-OF-FLIGHT MASS-SPECTROMETRY - AN EXAMINATION OF EXPERIMENTAL CONSEQUENCES
    COLBY, SM
    REILLY, JP
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1994, 131 : 125 - 138
  • [6] A PHOTOEMITTED ELECTRON-IMPACT IONIZATION METHOD FOR TIME-OF-FLIGHT MASS SPECTROMETERS
    CHENG, PY
    DAI, HL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (08): : 2211 - 2214
  • [7] An optimised compact electron impact ion storage source for a time-of-flight mass spectrometer
    Abplanalp, Dominic
    Wurz, Peter
    Huber, Liliane
    Leya, Ingo
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2010, 294 (01) : 33 - 39
  • [8] Development of a new electron ionization/field ionization ion source for gas chromatography/time-of-flight mass spectrometry
    Miyamoto, Kenji
    Fujimaki, Susumu
    Ueda, Yoshihisa
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (20) : 3350 - 3354
  • [9] Dynamical time focus shift in multiple-reflection time-of-flight mass spectrometers
    Dickel, Timo
    Yavor, Mikhail I.
    Lang, Johannes
    Plass, Wolfgang R.
    Lippert, Wayne
    Geissel, Hans
    Scheidenberger, Christoph
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2017, 412 : 1 - 7
  • [10] TIME-OF-FLIGHT MASS-SPECTROMETRY WITH RAPID FIELD REVERSAL - HIGH TRANSMISSION WITH CONTINUOUS ELECTRON-IMPACT IONIZATION
    AXELSSON, E
    HOLMLID, L
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 59 (03): : 231 - 246