Successful Redo Surgical Replacement of a Flail Bioprosthetic Aortic Valve: A Case Report

被引:0
|
作者
Angirekula, Aakash [1 ]
Franco, Adam [1 ]
Patel, Kirit [2 ]
机构
[1] Univ Texas Austin, Coll Nat Sci, Austin, TX 78712 USA
[2] Med Ctr Hosp, Dept Cardiothorac Surg, Odessa, TX USA
来源
关键词
Aortic Valve Prolapse; Bicuspid Aortic Valve Disease; Sternotomy; Surgical Instruments; OUTCOMES; STENTLESS; STENOSIS;
D O I
10.12659/AJCR.945043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Congenital defects/diseases Background: In the last 2 decades, the use of bioprosthetic valves for surgical aortic valve replacements has surged, now accounting for over 85% of all such surgeries. However, their limited durability has led to an increase in aortic valve reoperations and re-interventions. Here, we describe a unique case involving a patient with severe aortic regurgitation and cardiogenic shock, caused by a bioprosthetic aortic valve with a flail leaflet, which was replaced via a surgical approach. Case Report: A 58-year-old man with a history of atrial fibrillation, stent placement in the left anterior descending artery, and 2 aortic valve replacements presented to the Emergency Department with severe chest pain and shortness of breath. A chest X-ray showed significant pulmonary vascular and interstitial congestion, and cardiac catheterization displayed nonobstructive coronary artery disease. A transesophageal echocardiogram (TEE) revealed severe regurgitation in the prosthetic aortic valve, resulting in the patient being sent for emergency aortic valve replacement. An intraoperative TEE showed evidence of prosthetic valve failure with complete prolapse of the noncoronary cusp. The prosthetic aortic valve's noncoronary cusp leaflet was found flailing into the left ventricular outflow tract, while the other 2 leaflets seemed normal. The valve was replaced and a new Medtronic Avalus size 27 mm valve was seated. Postoperatively, the patient developed a complete heart block requiring placement of a permanent dual-chamber pacemaker. Conclusions: Flailed leaflets in bioprosthetic aortic valves are a rare complication of aortic valve replacement. Redo surgical valve replacement is a viable treatment for bioprosthetic failure due to leaflet flail.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Comparison of redo surgery to percutaneous valve-in-valve replacement in patients with failed aortic bioprosthetic valves
    Mameri, A.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2017, 47 : 106 - 107
  • [32] Successful surgical intervention for delayed chylopericardial tamponade following aortic valve replacement: a case report
    Gyoten, Takayuki
    Doi, Toshio
    Fukahara, Kazuaki
    Yoshimura, Naoki
    JOURNAL OF CARDIOTHORACIC SURGERY, 2014, 9 : 190
  • [33] Successful surgical intervention for delayed chylopericardial tamponade following aortic valve replacement: a case report
    Takayuki Gyoten
    Toshio Doi
    Kazuaki Fukahara
    Naoki Yoshimura
    Journal of Cardiothoracic Surgery, 9
  • [34] Reoperative Surgical Aortic Valve Replacement Versus Transcatheter Valve-in-Valve Replacement for Degenerated Bioprosthetic Aortic Valves
    Ejiofor, Julius I.
    Yammine, Maroun
    Harloff, Morgan T.
    McGurk, Siobhan
    Muehlschlegel, Jochen D.
    Shekar, Prem S.
    Cohn, Lawrence H.
    Shah, Pinak
    Kaneko, Tsuyoshi
    ANNALS OF THORACIC SURGERY, 2016, 102 (05): : 1452 - 1458
  • [35] Recent Outcomes of Surgical Redo Aortic Valve Replacement in Prosthetic Valve Failure
    Kang, Yoonjin
    Soehartono, Nazla Amanda
    Choi, Jae Woong
    Kim, Kyung Hwan
    Hwang, Ho Young
    Kim, Joon Bum
    Kim, Hong Rae
    Lee, Seung Hyun
    Cho, Yang Hyun
    THORACIC AND CARDIOVASCULAR SURGEON, 2024,
  • [36] Valve-in-Valve Transcatheter Implantation Versus Redo Surgical Aortic Valve Replacement
    Malik, Aaqib H.
    Yandrapalli, Srikanth
    Zaid, Syed
    Shetty, Suchith S.
    Aronow, Wilbert S.
    Ahmad, Hasan
    Tang, Gilbert H. L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2020, 125 (09): : 1378 - 1384
  • [37] Sex Difference in Outcomes of Redo- Surgical Aortic Valve Replacement (redo-SAVR) for Failed Bioprosthetic Aortic Valves: Insights From the National Inpatient Sample
    Rivera, Frederick B.
    Yan, Linjie
    Zhao, Jiahe
    Choi, Sarang
    Priela, Lia Veronique
    Collado, Fareed Moses M.
    CIRCULATION, 2023, 148
  • [38] Acute valve malfunction with thrombosed bioprosthetic valve after surgical aortic valve replacement
    Moriuchi, Hiroki
    Koide, Masaaki
    Kunii, Yoshifumi
    Maeda, Takuya
    Shimbori, Risa
    CLINICAL CASE REPORTS, 2023, 11 (10):
  • [39] Valve-in-Valve Transcatheter Aortic Valve Replacement Versus Redo Surgical Aortic Valve Replacement An Updated Meta-Analysis
    Sa, Michel Pompeu B. O.
    Van den Eynde, Jef
    Simonato, Matheus
    Cavalcanti, Luiz Rafael P.
    Doulamis, Ilias P.
    Weixler, Viktoria
    Kampaktsis, Polydoros N.
    Gallo, Michele
    Laforgia, Pietro L.
    Zhigalov, Konstantin
    Ruhparwar, Arjang
    Weymann, Alexander
    Pibarot, Philippe
    Clavel, Marie-Annick
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (02) : 211 - 220
  • [40] Early and Midterm Clinical Outcomes of Transcatheter Valve-in-Valve Implantation Versus Redo Surgical Aortic Valve Replacement for Aortic Bioprosthetic Valve Degeneration: Two Faces of the Same Medal
    Dokollari, Aleksander
    Cameli, Matteo
    Mandoli, Giulia Elena
    Kalra, Didar-Karan S.
    Poston, Robert
    Coku, Lindita
    Pernoci, Marjela
    Miri, Mirian
    Bonacchi, Massimo
    Gelsomino, Sandro
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (11) : 3223 - 3231