Successful Redo Surgical Replacement of a Flail Bioprosthetic Aortic Valve: A Case Report

被引:0
|
作者
Angirekula, Aakash [1 ]
Franco, Adam [1 ]
Patel, Kirit [2 ]
机构
[1] Univ Texas Austin, Coll Nat Sci, Austin, TX 78712 USA
[2] Med Ctr Hosp, Dept Cardiothorac Surg, Odessa, TX USA
来源
关键词
Aortic Valve Prolapse; Bicuspid Aortic Valve Disease; Sternotomy; Surgical Instruments; OUTCOMES; STENTLESS; STENOSIS;
D O I
10.12659/AJCR.945043
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Congenital defects/diseases Background: In the last 2 decades, the use of bioprosthetic valves for surgical aortic valve replacements has surged, now accounting for over 85% of all such surgeries. However, their limited durability has led to an increase in aortic valve reoperations and re-interventions. Here, we describe a unique case involving a patient with severe aortic regurgitation and cardiogenic shock, caused by a bioprosthetic aortic valve with a flail leaflet, which was replaced via a surgical approach. Case Report: A 58-year-old man with a history of atrial fibrillation, stent placement in the left anterior descending artery, and 2 aortic valve replacements presented to the Emergency Department with severe chest pain and shortness of breath. A chest X-ray showed significant pulmonary vascular and interstitial congestion, and cardiac catheterization displayed nonobstructive coronary artery disease. A transesophageal echocardiogram (TEE) revealed severe regurgitation in the prosthetic aortic valve, resulting in the patient being sent for emergency aortic valve replacement. An intraoperative TEE showed evidence of prosthetic valve failure with complete prolapse of the noncoronary cusp. The prosthetic aortic valve's noncoronary cusp leaflet was found flailing into the left ventricular outflow tract, while the other 2 leaflets seemed normal. The valve was replaced and a new Medtronic Avalus size 27 mm valve was seated. Postoperatively, the patient developed a complete heart block requiring placement of a permanent dual-chamber pacemaker. Conclusions: Flailed leaflets in bioprosthetic aortic valves are a rare complication of aortic valve replacement. Redo surgical valve replacement is a viable treatment for bioprosthetic failure due to leaflet flail.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Redo aortic valve replacement with "porcelain" aorta in an aortitis patient - A case report
    Takahashi, T
    Ando, M
    Okita, Y
    Tagusari, O
    Hanabusa, Y
    Kitamura, S
    JOURNAL OF CARDIOVASCULAR SURGERY, 2005, 46 (01): : 77 - 79
  • [22] Premature Bioprosthetic Mitral Valve Dysfunction Due to Flail Leaflet Treated With Transcatheter Mitral Valve Replacement; a Case Report
    Munoz, Carlos
    Valencia, Carla
    Scoma, Christopher
    Fernandez, Joel
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (10)
  • [23] Redo surgical aortic valve replacement for prosthetic valve valve-in-valve dysfunction
    Tavilla, Giuseppe
    Malhotra, Amber
    Gunn, Brady
    Beckles, Daniel L.
    Reddy, Ramachandra C.
    JOURNAL OF CARDIAC SURGERY, 2022, 37 (04) : 1098 - 1100
  • [24] Valve in Valve Transcatheter Versus Redo Surgical Replacement of a Failing Bioprosthetic Aortic Valve: An Updated MetaAnalysis of Echocardiographic and Long-Term Outcomes
    Dimitriadis, Kyriakos
    Pyrpyris, Nikolaos
    Aznaouridis, Konstantinos
    Beneki, Eirini
    Tsioufis, Panagiotis
    Fragkoulis, Christos
    Antonopoulos, Alexios
    Aggeli, Konstantina
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B305 - B306
  • [25] Valve-in-Valve Transcatheter Versus Redo Surgical Replacement of a Failing Bioprosthetic Aortic Valve: An Updated Systematic Review and Meta-Analysis
    Dimitriadis, Kyriakos
    Pyrpyris, Nikolaos
    Aznaouridis, Konstantinos
    Beneki, Eirini
    Tsioufis, Panagiotis
    Koutsopoulos, Georgios
    Fragkoulis, Christos
    Antonopoulos, Alexios
    Aggeli, Konstantina
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 84 (18) : B390 - B390
  • [26] Inverted aortic bioprosthetic for mitral valve replacement with Ross procedure: case report
    McPherson, Iain
    Bayliss, Christopher
    Generali, Tommaso
    Booth, Karen
    Hasan, Asif
    CARDIOTHORACIC SURGEON, 2021, 29 (01):
  • [27] Inverted aortic bioprosthetic for mitral valve replacement with Ross procedure: case report
    Iain McPherson
    Christopher Bayliss
    Tommaso Generali
    Karen Booth
    Asif Hasan
    The Cardiothoracic Surgeon, 29
  • [28] Redo aortic valve replacement due to early structural valve deterioration in a trifecta valve: A case report
    Watanabe, Tatsuya
    Tokunaga, Noriyuki
    Maruno, Keita
    Yoshida, Hideo
    Kuinose, Masahiko
    INTERNATIONAL JOURNAL OF SURGERY CASE REPORTS, 2021, 86
  • [29] Anticoagulation After Surgical or Transcatheter Bioprosthetic Aortic Valve Replacement
    Chakravarty, Tarun
    Patel, Akshar
    Kapadia, Samir
    Raschpichler, Matthias
    Smalling, Richard W.
    Szeto, Wilson Y.
    Abramowitz, Yigal
    Cheng, Wen
    Douglas, Pamela S.
    Hahn, Rebecca T.
    Herrmann, Howard C.
    Kereiakes, Dean
    Svensson, Lars
    Yoon, Sung-Han
    Babaliaros, Vasilis C.
    Kodali, Susheel
    Thourani, Vinod H.
    Alu, Maria C.
    Liu, Yangbo
    McAndrew, Thomas
    Mack, Michael
    Leon, Martin B.
    Makkar, Raj R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (09) : 1190 - 1200
  • [30] TRANSCATHETER VALVE-IN-VALVE REPLACEMENT VERSUS REDO AORTIC VALVE SURGERY FOR BIOPROSTHETIC AORTIC VALVE DYSFUNCTION: A META-ANALYSIS
    Neupane, Saroj
    Singh, Hemindermeet
    Laemmer, Johannes
    Othman, Hussein
    Yamasaki, Hiroshi
    Rosman, Howard
    Bossone, Eduardo
    Mehta, Rajendra
    Eggebrecht, Holger
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1411 - 1411