Reliability and relevance of the ES®-RHE model for in vitro skin irritation test application

被引:0
|
作者
Mini, C. A. [1 ]
Ballestero, G. [1 ]
Munari, C. C. [1 ]
Carrao, D. B. [1 ]
Fonseca, B. C. [1 ]
Albuquerque, N. C. [1 ]
Marquele-Oliveira, F. [1 ]
机构
[1] Eleve Sci Pesquisa & Desenvolvimento Ltda, Super Parque Tecnol Ribeirao Preto USP, Ribeirao Preto, SP, Brazil
关键词
Reconstructed human epidermis; OECD; 439; Skin irritation test; In vitro model; ES (R)-RHE; RECONSTRUCTED HUMAN EPIDERMIS;
D O I
10.1016/j.tiv.2024.105932
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Introduction: In vitro methods have been widely used to assess adverse effects. Reconstructed Human Epidermis (RHE) poses as a fascinating test system employed to assess the dermal irritation hazard potential of chemicals. Although several RHE models are reported in the OECD Test Guideline No. 439, the OECD Document No. 220 encourages the scientific community to develop and validate new RHE test systems due to its relevance for socioeconomic advancement. Methods: Following the criteria documented in the OECD No. 220, a blind study for skin irritation (OECD 439) was conducted employing the Minimum List of Reference Chemicals for Determination of Reproducibility and Predictive Capacity using ES (R)-RHE. Structural and functional characteristics were assessed alongside the prediction model. Results: The model has shown reproducibility of optical density and barrier function, similarly to internationally validated methods. Furthermore, it shows the cell layers' development and differentiation ability due to Cytokeratin14, Cytokeratin10, and filaggrin expression. The prediction model resulted in sensitivity, specificity and accuracy rates of 100, 70, and 77 %, respectively. Conclusions: The ES (R)-RHE demonstrated reliability and relevance, with similar structural and functional characteristics comparable to internationally validated models, in addition to the accepted predictive capacity according to OECD required minimum criteria, thus confirming the suitability of the national ES (R)-RHE in the hazard prediction of dermal irritation based on OECD Test Guideline No. 439.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Relevance of in vitro methods for the evaluation of eye and skin irritation/corrosion potential of aliphatic tertiary amines
    Li, Qiang
    Kreiling, Reinhard
    TOXICOLOGY LETTERS, 2013, 221 : S160 - S160
  • [32] The isolated perfused bovine udder skin model: A new in vitro model for the assessment of skin penetration and irritation
    Pittermann, W
    Jackwerth, B
    Schmitt, M
    IN VITRO TOXICOLOGY, 1997, 10 (01) : 17 - 21
  • [33] A prevalidation study on the in vitro skin irritation function test (SIFT) for prediction of acute skin irritation in vivo: results and evaluation of ECVAM Phase III
    Heylings, JR
    Diot, S
    Esdaile, DJ
    Fasano, WJ
    Manning, LA
    Owen, HM
    TOXICOLOGY IN VITRO, 2003, 17 (02) : 123 - 138
  • [34] Pre-validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm™
    Helena, Kandarova
    Jamin, Willoughby A.
    Wim, De Jong H.
    Silvia, Letasiova
    Tatiana, Milasova
    Michael, Bachelor A.
    Bridget, Breyfogle
    Handa, Yuki
    Liset, De la Fonteyne
    Kelly, Coleman P.
    TOXICOLOGY IN VITRO, 2018, 50 : 407 - 417
  • [35] Development, optimization and validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm
    Kandarova, H.
    Willoughby, J.
    De Jong, W.
    Bachelor, M. A.
    Letasiova, S.
    Milasova, T.
    Breyfogle, B.
    de la Fonteyne, L.
    Haishima, Y.
    Ayehunie, S.
    Coleman, K.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2016, 136 (08) : B8 - B8
  • [36] Development, optimization and standardization of an in vitro skin irritation test for medical devices using the reconstructed human tissue model epiderm
    Kandarova, H.
    Willoughby, J.
    de Jong, W.
    Bachelor, M.
    Letasiova, S.
    Breyfogle, B.
    de la Fonteyne, L.
    Coleman, K.
    TOXICOLOGY LETTERS, 2015, 238 (02) : S351 - S352
  • [37] Development, optimization and validation of an in vitro skin irritation test for medical devices using the reconstructed human tissue model EpiDerm
    Kandarova, H.
    Willoughby, J. A.
    De Jong, W. H.
    Bachelor, M. A.
    Letasiova, S.
    Milasova, T.
    Breyfogle, B.
    De la Fonteyne, L.
    Haishima, Y.
    Coleman, K. P.
    TOXICOLOGY LETTERS, 2016, 258 : S63 - S63
  • [38] Validation study of a new reconstructed human epidermis model EPiTRI for in vitro skin irritation test according to OECD guidelines
    Liao, Chih-Ching
    Wu, Cheng-Yi
    Lin, Meng-Hsueh
    Hsieh, Feng-Koo
    Hsu, Lih-Tao
    Chang, Shiun-Yin
    Chen, Kuan-Jen
    Huang, Hui-Ting
    Hsu, Hui-Chun
    Lin, Chiu-Hsing
    Lin, Pei-Ju
    Lai, Huey-Min
    Kojima, Hajime
    Todo, Hiroaki
    Lin, Sung-Jan
    Li, Jih-Heng
    Chen, Wannhsin
    TOXICOLOGY IN VITRO, 2021, 75
  • [39] Assessment of test method variables for in vitro skin irritation testing of medical device extracts
    Olsen, Daniel S.
    Lee, Michelle
    Turley, Audrey P.
    TOXICOLOGY IN VITRO, 2018, 50 : 426 - 432
  • [40] Development of skin corrosion and irritation test methods employing ex vivo porcine skin model
    Hong, Jeong-hyun
    Lim, Kyung-Min
    TOXICOLOGY IN VITRO, 2025, 106