An investigation into the buckling behaviour of hybrid fibre reinforced polymer-timber thin-walled C-section columns

被引:0
|
作者
Wen, Ye [1 ]
Fernando, Dilum [2 ]
Gilbert, Benoit P. [3 ]
Bailleres, Henri [4 ]
Hu, Rongrong [5 ]
Bisby, Luke [2 ]
Roy, Dipa [2 ]
机构
[1] Univ Queensland, Sch Civil Engn, St Lucia, Qld, Australia
[2] Univ Edinburgh, Sch Engn, Edinburgh, Scotland
[3] Griffith Univ, Sch Engn & Built Environm, Southport, Qld, Australia
[4] Hyne Timber, Maryborough, Qld, Australia
[5] Xian Univ Architecture & Technol, Sch Architecture, Xian, Peoples R China
关键词
Hybrid fibre reinforced polymer timber; local buckling; global buckling; thin-walled structures; light-weight structures; ALUMINUM-ALLOY COLUMNS; DESIGN; TESTS;
D O I
10.1177/13694332241269249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hybrid fibre reinforced polymer (FRP)-timber (HFT) thin-walled structural members are a novel technology developed recently as a sustainable alternative to thin-walled steel and aluminium structures. HFT structures are made by forming thin timber veneers and FRP laminates into efficient cross-sectional geometries. While existing studies have demonstrated the potential of HFT thin-walled members to be used as structural elements, a systematic study to investigate the behaviour of HFT thin-walled structures is yet to be carried out. This paper presents a study aimed at investigating the behaviour of HFT C-section columns under concentric axial loading. In total five HFT C-section specimens each from 700 mm to 2000 mm lengths were fabricated and tested. It was found that shorter HFT C-section columns failed due to local buckling while increase in length changed the failure mode to global buckling. Effect of GF orientation and density on load carrying capacity of the HFT C-section columns was investigated numerically. It was found that it's necessary to provide adequate GF volume in transverse to axis direction, but further increase in GF volume in transverse direction did not significantly increase the load carrying capacity. Increase in GF density in parallel to axis direction increased the load carrying capacity.
引用
收藏
页码:2409 / 2428
页数:20
相关论文
共 50 条
  • [41] Influence of autoclaving process parameters on the buckling and postbuckling behaviour of thin-walled channel section beams
    Bienias, Jaroslaw
    Gliszczynski, Adrian
    Jakubczak, Patryk
    Kubiak, Tomasz
    Majerski, Krzysztof
    THIN-WALLED STRUCTURES, 2014, 85 : 262 - 270
  • [42] On the local and global buckling behaviour of angle, T-section and cruciform thin-walled members
    Dinis, Pedro B.
    Camotim, Dinar
    Silvestre, Nuno
    THIN-WALLED STRUCTURES, 2010, 48 (10-11) : 786 - 797
  • [43] Investigation of dynamic buckling of fiber metal laminate thin-walled columns under axial compression
    Zaczynska, M.
    Mania, R. J.
    COMPOSITE STRUCTURES, 2021, 271
  • [44] Dynamic buckling load of thin-walled columns of closed cross-section subjected to pulse compression
    Kowal-Michalska, K
    Mania, R
    Shell Structures: Theory and Applications, 2005, : 353 - 357
  • [45] Thermal Buckling Analysis of Axially Loaded Columns of Thin-Walled Open Section with Nonuniform Sectional Properties
    Cheng, Shanshan
    Yan, Qi-Wu
    Li, Long-Yuan
    Kim, Boksun
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2015, 15 (06)
  • [46] Modeling of the Lateral-Torsional Buckling of the Functionally Graded Material Open Section Thin-Walled Columns
    Huang, Bin
    INTERNATIONAL JOURNAL OF APPLIED MECHANICS, 2025,
  • [47] An investigation of the processability of natural fibre reinforced polymer composites on shallow and flat thin-walled parts by injection moulding process
    Azaman, M. D.
    Sapuan, S. M.
    Sulaiman, S.
    Zainudin, E. S.
    Abdan, K.
    MATERIALS & DESIGN, 2013, 50 : 451 - 456
  • [48] Investigation on Distortion Buckling Behavior of Cold-formed Thin-walled Steel Built-up Box-section Columns
    Li Y.
    Zhou T.
    Ding J.
    Li C.
    Zhang X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2021, 48 (11): : 91 - 100
  • [49] Theoretical Study of Glass Fibre Reinforced Polymer-steel Hybrid Thin-walled Twelve-right-angle-section Beams under Bending Loading
    Chen G.
    Wei C.
    Xie D.
    Zheng N.
    Feng Y.
    Chen Y.
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2022, 58 (06): : 194 - 201
  • [50] Tolerance simulation of thin-walled C-section composite beam assembling with small displacement torsor model
    Wang, Hua
    Liu, Jun
    14TH CIRP CAT 2016 - CIRP CONFERENCE ON COMPUTER AIDED TOLERANCING, 2016, 43 : 274 - 279