An investigation into the buckling behaviour of hybrid fibre reinforced polymer-timber thin-walled C-section columns

被引:0
|
作者
Wen, Ye [1 ]
Fernando, Dilum [2 ]
Gilbert, Benoit P. [3 ]
Bailleres, Henri [4 ]
Hu, Rongrong [5 ]
Bisby, Luke [2 ]
Roy, Dipa [2 ]
机构
[1] Univ Queensland, Sch Civil Engn, St Lucia, Qld, Australia
[2] Univ Edinburgh, Sch Engn, Edinburgh, Scotland
[3] Griffith Univ, Sch Engn & Built Environm, Southport, Qld, Australia
[4] Hyne Timber, Maryborough, Qld, Australia
[5] Xian Univ Architecture & Technol, Sch Architecture, Xian, Peoples R China
关键词
Hybrid fibre reinforced polymer timber; local buckling; global buckling; thin-walled structures; light-weight structures; ALUMINUM-ALLOY COLUMNS; DESIGN; TESTS;
D O I
10.1177/13694332241269249
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hybrid fibre reinforced polymer (FRP)-timber (HFT) thin-walled structural members are a novel technology developed recently as a sustainable alternative to thin-walled steel and aluminium structures. HFT structures are made by forming thin timber veneers and FRP laminates into efficient cross-sectional geometries. While existing studies have demonstrated the potential of HFT thin-walled members to be used as structural elements, a systematic study to investigate the behaviour of HFT thin-walled structures is yet to be carried out. This paper presents a study aimed at investigating the behaviour of HFT C-section columns under concentric axial loading. In total five HFT C-section specimens each from 700 mm to 2000 mm lengths were fabricated and tested. It was found that shorter HFT C-section columns failed due to local buckling while increase in length changed the failure mode to global buckling. Effect of GF orientation and density on load carrying capacity of the HFT C-section columns was investigated numerically. It was found that it's necessary to provide adequate GF volume in transverse to axis direction, but further increase in GF volume in transverse direction did not significantly increase the load carrying capacity. Increase in GF density in parallel to axis direction increased the load carrying capacity.
引用
收藏
页码:2409 / 2428
页数:20
相关论文
共 50 条
  • [22] Compressive behaviour of corroded thin-walled circular section steel stub columns
    Sha-Sha, Song
    Xu, Liu
    Ju, Chen
    Changhu, Ye
    Jiadaren, Liu
    Chengbin, Liu
    THIN-WALLED STRUCTURES, 2022, 180
  • [23] Manufacture and structural performance of modular hybrid FRP-timber thin-walled columns
    Cui, Weiqi
    Fernando, Dilum
    Heitzmann, Michael
    Gattas, Joseph M.
    COMPOSITE STRUCTURES, 2021, 260
  • [24] Effect of Load Eccentricity on The Buckling of Thin-Walled Laminated C-columns
    Wysmulski, Pawel
    Teter, Andrzej
    Debski, Hubert
    COMPUTER METHODS IN MECHANICS (CMM2017), 2018, 1922
  • [25] Local buckling behaviour of thin-walled members with curved cross-section parts
    Jobbagy, David
    Adany, Sandor
    THIN-WALLED STRUCTURES, 2017, 115 : 264 - 276
  • [26] Distortional buckling of composite thin-walled columns of a box-type cross section with diaphragms
    Szymczak, Czeslaw
    Kujawa, Marcin
    ACTA MECHANICA, 2019, 230 (11) : 3945 - 3961
  • [27] Local and distortional buckling stress methods of open cross-section thin-walled columns
    Zhang, SM
    Wu, S
    PROCEEDINGS OF THE EIGHTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS 1 AND 2, 2004, : 112 - 120
  • [28] Local buckling and post-critical behavior of thin-walled composite channel section columns
    Medeiros D'Aguiar, Savanna Cristina
    Parente Junior, Evandro
    LATIN AMERICAN JOURNAL OF SOLIDS AND STRUCTURES, 2018, 15 (07):
  • [29] Distortional buckling of composite thin-walled columns of a box-type cross section with diaphragms
    Czesław Szymczak
    Marcin Kujawa
    Acta Mechanica, 2019, 230 : 3945 - 3961
  • [30] Torsional buckling experiments on wide-flange thin-walled Z-section columns
    Fish, RAD
    Lee, M
    Rasmussen, KJR
    ADVANCES IN STEEL STRUCTURES, VOLS I & II, PROCEEDINGS, 2002, : 357 - 364