Clinical implementation of a commercial synthetic computed tomography solution for radiotherapy treatment of glioblastoma

被引:2
|
作者
Emin, Sevgi [1 ]
Rossi, Elia [2 ]
Rooth, Elisabeth Myrvold [2 ]
Dorniok, Torsten [1 ]
Hedman, Mattias [2 ,3 ]
Gagliardi, Giovanna [1 ,3 ]
Villegas, Fernanda [1 ,3 ]
机构
[1] Karolinska Univ Hosp, Dept Med Radiat Phys & Nucl Med, S-17176 Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Radiat Oncol, S-17176 Stockholm, Sweden
[3] Karolinska Inst, Dept Oncol Pathol, S-17177 Stockholm, Sweden
关键词
MR-only; Glioblastoma; Radiotherapy; Synthetic-CT; ACCURACY; MRI;
D O I
10.1016/j.phro.2024.100589
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and Purpose: Magnetic resonance (MR)-only radiotherapy (RT) workflow eliminates uncertainties due to computed tomography (CT)-MR image registration, by using synthetic CT (sCT) images generated from MR. This study describes the clinical implementation process, from retrospective commissioning to prospective validation stage of a commercial artificial intelligence (AI)-based sCT product. Evaluation of the dosimetric performance of the sCT is presented, with emphasis on the impact of voxel size differences between image modalities. Materials and methods: sCT performance was assessed in glioblastoma RT planning. Dose differences for 30 patients in both commissioning and validation cohorts were calculated at various dose-volume-histogram (DVH) points for target and organs-at-risk (OAR). A gamma analysis was conducted on regridded image plans. Quality assurance (QA) guidelines were established based on commissioning phase results. Results: Mean dose difference to target structures was found to be within +/- 0.7 % regardless of image resolution and cohort. OARs' mean dose differences were within +/- 1.3 % for plans calculated on regridded images for both cohorts, while differences were higher for plans with original voxel size, reaching up to -4.2 % for chiasma D2% in the commissioning cohort. Gamma passing rates for the brain structure using the criteria 1 %/1mm, 2 %/2mm and 3 %/3mm were 93.6 %/99.8 %/100 % and 96.6 %/99.9 %/100 % for commissioning and validation cohorts, respectively. Conclusions: Dosimetric outcomes in both commissioning and validation stages confirmed sCT's equivalence to CT. The large patient cohort in this study aided in establishing a robust QA program for the MR-only workflow, now applied in glioblastoma RT at our center.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Synthetic Enhancement of Cone Beam Computed Tomography (CBCT) for Adaptive Radiotherapy Using Deep Learning Algorithms
    Lemus, O. M. D.
    Wang, Y. F.
    Horowitz, D. P.
    Xu, Y.
    Wuu, C. S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S42 - S42
  • [42] Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography
    Xavier J. Juan-Senabre
    Carlos Ferrer-Albiach
    Marta Rodríguez-Cordón
    Agustín Santos-Serra
    Juan López-Tarjuelo
    Salvador Calzada-Feliu
    Clinical and Translational Oncology, 2009, 11 : 253 - 256
  • [43] Retroperitoneal tumour radiotherapy: clinical improvements using kilovoltage cone beam computed tomography
    Juan-Senabre, Xavier J.
    Ferrer-Albiach, Carlos
    Rodriguez-Cordon, Marta
    Santos-Serra, Agustin
    Lopez-Tarjuelo, Juan
    Calzada-Feliu, Salvador
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2009, 11 (04): : 253 - 256
  • [44] Hurdles in radiation planning for glioblastoma: Can delayed-contrast enhanced computed tomography be a potential solution?
    Kunnar, Narendra
    Hanumanthappa, Nikesh
    Miriyala, Raviteja
    Vyas, Sanneer
    Salunke, Pravin
    Oinam, Arun S.
    Yadav, Budhi S.
    Madan, Renu
    Dracham, Chinnababu
    Kapoor, Rakesh
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2019, 15 (05) : E103 - E108
  • [45] Treatment planning for heavy ion radiotherapy:: clinical implementation and application
    Jäkel, O
    Krämer, M
    Karger, CP
    Debus, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (04): : 1101 - 1116
  • [46] Justifying the implementation of intraoperative computed tomography for midface fracture treatment in improving outcomes
    Sritharan, R.
    Arya, R.
    Abdelrahman, A.
    Parmar, S.
    Sharp, I.
    Breeze, J.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2023, 61 (04): : 315 - 319
  • [47] ROLE OF NURSES FOR THE IMPLEMENTATION OF TTFIELDS IN DAILY CLINICAL ROUTINE IN GLIOBLASTOMA TREATMENT
    Kilias, Mandy
    Pellet, Cristina
    NEURO-ONCOLOGY, 2017, 19 : 209 - 209
  • [48] Clinical implementation of artificial intelligence-driven cone-beam computed tomography-guided online adaptive radiotherapy in the pelvic region
    Sibolt, Patrik
    Andersson, Lina M.
    Calmels, Lucie
    Sjostrom, David
    Bjelkengren, Ulf
    Geertsen, Poul
    Behrens, Claus F.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2021, 17 : 1 - 7
  • [49] Magnetic resonance-based synthetic computed tomography images generated using generative adversarial networks for nasopharyngeal carcinoma radiotherapy treatment planning
    Peng, Yinglin
    Chen, Shupeng
    Qin, An
    Chen, Meining
    Gao, Xingwang
    Liu, Yimei
    Miao, Jingjing
    Gu, Huikuan
    Zhao, Chong
    Deng, Xiaowu
    Qi, Zhenyu
    RADIOTHERAPY AND ONCOLOGY, 2020, 150 : 211 - 218
  • [50] THE CONTRIBUTION OF COMPUTED-TOMOGRAPHY TO RADIOTHERAPY PLANNING AND TREATMENT OUTCOME IN BLADDER-CANCER
    ROTHWELL, RI
    ASH, DV
    THOROGOOD, J
    BRITISH JOURNAL OF RADIOLOGY, 1985, 58 (692): : 809 - 809