Design and Test of an Intraoral Electrode Grid for Tongue High-Density Electromyography

被引:0
|
作者
Botter, Alberto [1 ,2 ]
Vieira, Taian [1 ,2 ]
Busso, Chiara [3 ]
Vitali, Federica [1 ,2 ]
Gazzoni, Marco [1 ,2 ]
Cerone, Giacinto L. [1 ,2 ]
机构
[1] Politecn Torino, Dept Elect & Telecommun, Lab Engn Neuromuscular Syst LISiN, I-10129 Turin, Italy
[2] Politecn Torino, Polito BIOMed Lab, I-10129 Turin, Italy
[3] Univ Turin, Dept Surg Sci, Div Phys Med & Rehabil, I-10124 Turin, Italy
关键词
Electrode technology; electromyography; motor unit; decomposition; speech; tongue muscles; BIOMECHANICAL MODEL; SURFACE; SYSTEM; ARRAY;
D O I
10.1109/TNSRE.2024.3434360
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Tongue motor function is crucial in a wide range of basic activities and its impairment affects quality of life. The electrophysiological assessment of the tongue relies primarily on needle electromyography, which is limited by its invasiveness and inability to capture the concurrent activity of the different tongue muscles. This work aimed at developing an intraoral grid for high-density surface electromyography (HDsEMG) to non-invasively map the electrical excitation of tongue muscles. We developed a grid of 4 x 8 electrodes deposited over an adhesive 8- $\mu $ m thick polyurethane membrane. The testing protocol was conducted on 7 healthy participants and included functional tasks (vowels articulation and tongue movements) aimed at activating different regions of the tongue. The electrical stability of contact was assessed by measuring electrode-tongue impedances before and after the tasks. The spatial amplitude distribution of global EMG and single motor unit action potentials (MUAPs) was characterized. Electrode-tongue impedance magnitude showed no significant changes in the pre-post comparison (58 +/- 46k Omega vs. 67 +/- 58k Omega at 50Hz). Contact stability was confirmed by the quality of the signals that allowed to quantify spatiotemporal characteristics of muscle activation during the different tasks. The analysis of the spatial distribution of individual MUAPs amplitude showed that they were confined to relatively small areas on the tongue surface (range: 0.5cm(2) -3.9cm(2)). A variety of different spatiotemporal MUAP patterns, likely due to the presence of different muscle compartments with different fiber orientations, were observed. Our results demonstrate that the developed electrode grid enables HDsEMG acquisition from the tongue during functional tasks, thus opening new possibilities in tongue muscle assessment both at global and single motor unit level.
引用
收藏
页码:2805 / 2814
页数:10
相关论文
共 50 条
  • [1] Design of a Flexible High-Density Surface Electromyography Sensor
    Feng, Jirou
    Chang, Handdeut
    Jeong, Hwayeong
    Kim, Jung
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4130 - 4133
  • [2] Design, Fabrication and Evaluation of a Stretchable High-Density Electromyography Array
    Varghese, Rejin John
    Pizzi, Matteo
    Kundu, Aritra
    Grison, Agnese
    Burdet, Etienne
    Farina, Dario
    SENSORS, 2024, 24 (06)
  • [3] Consensus for experimental design in electromyography (CEDE) project: High-density surface electromyography matrix
    Gallina, Alessio
    Disselhorst-Klug, Catherine
    Farina, Dario
    Merletti, Roberto
    Besomi, Manuela
    Holobar, Ales
    Enoka, Roger M.
    Hug, Francois
    Falla, Deborah
    Sogaard, Karen
    McGill, Kevin
    Clancy, Edward A.
    Carson, Richard G.
    van Dieen, Jaap H.
    Gandevia, Simon
    Lowery, Madeleine
    Besier, Thor
    Kiernan, Matthew C.
    Rothwell, John C.
    Tucker, Kylie
    Hodges, Paul W.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2022, 64
  • [4] Conducting Polymer-Ionic Liquid Electrode Arrays for High-Density Surface Electromyography
    Velasco-Bosom, Santiago
    Karam, Nuzli
    Carnicer-Lombarte, Alejandro
    Gurke, Johannes
    Casado, Nerea
    Tome, Liliana C.
    Mecerreyes, David
    Malliaras, George G.
    ADVANCED HEALTHCARE MATERIALS, 2021, 10 (17)
  • [5] Towards optimizing electrode configurations for silent speech recognition based on high-density surface electromyography
    Zhu, Mingxing
    Zhang, Haoshi
    Wang, Xiaochen
    Wang, Xin
    Yang, Zijian
    Wang, Cheng
    Samuel, Oluwarotimi Williams
    Chen, Shixiong
    Li, Guanglin
    JOURNAL OF NEURAL ENGINEERING, 2021, 18 (01)
  • [6] High-density Surface Electromyography as Biomarker of Muscle Aging
    Imrani, Loubna
    Boudaoud, Sofiane
    Lahaye, Clement
    Moreau, Caroline
    Ghezal, Myriam
    Ben Manaa, Safa
    Doulazmi, Mohamed
    Laforet, Jeremy
    Marin, Frederic
    Kinugawa, Kiyoka
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2023, 78 (01): : 25 - 33
  • [7] Analysis of motor units with high-density surface electromyography
    Merletti, Roberto
    Holobar, Ales
    Farina, Dario
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2008, 18 (06) : 879 - 890
  • [8] High-density electromyography activity in various hamstring exercises
    Hegyi, Andras
    Csala, Daniel
    Peter, Annamaria
    Finni, Taija
    Cronin, Neil J.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2019, 29 (01) : 34 - 43
  • [9] Stretchable high-density surface electromyography electrode patch assisted with machine learning for silent speech recognition
    Lin, Kai
    Hong, Weijie
    Huang, Chongyuan
    Su, Yanyan
    Zhang, Shun
    Wang, Chengjun
    Song, Jizhou
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2025,
  • [10] High-density magnetomyography is superior to high-density surface electromyography for motor unit decomposition: a simulation study
    Klotz, Thomas
    Lehmann, Lena
    Negro, Francesco
    Roehrle, Oliver
    JOURNAL OF NEURAL ENGINEERING, 2023, 20 (04)