Dual-beam X-ray nano-holotomography

被引:0
|
作者
Flenner, Silja [1 ]
Kubec, Adam [2 ]
David, Christian [2 ]
Greving, Imke [1 ]
Hagemann, Johannes [3 ,4 ]
机构
[1] Helmholtz Zentrum Hereon, Max Planck Stra ss 1, Max Planck Str 1, D-21502 Geesthacht, Germany
[2] Paul Scherrer Inst, Forschungs Str 111, CH-5232 Villigen, Switzerland
[3] Deutsch Elektronen Synchrotron DESY, Ctr X ray & Nano Sci CXNS, Notkestr 85, D-22607 Hamburg, Germany
[4] Deutsch Elektronen Synchrotron DESY, Helmholtz Imaging Platform, Notkestr 85, D-22607 Hamburg, Germany
关键词
multibeams; holography; nanotomography; dual beam configuration; holotomography; REAL-TIME;
D O I
10.1107/S1600577524003801
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nanotomography with hard X-rays is a widely used technique for high-resolution imaging, providing insights into the structure and composition of various materials. In recent years, tomographic approaches based on simultaneous illuminations of the same sample region from different angles by multiple beams have been developed at micrometre image resolution. Transferring these techniques to the nanoscale is challenging due to the loss in photon flux by focusing the X-ray beam. We present an approach for multi-beam nanotomography using a dual-beam Fresnel zone plate (dFZP) in a near-field holography setup. The dFZP generates two nano-focused beams that overlap in the sample plane, enabling the simultaneous acquisition of two projections from slightly different angles. This first proof-of-principle implementation of the dual-beam setup allows for the efficient removal of ring artifacts and noise using machinelearning approaches. The results open new possibilities for full-field multi-beam nanotomography and pave the way for future advancements in fast holotomography and artifact-reduction techniques.
引用
收藏
页码:916 / 922
页数:7
相关论文
共 50 条
  • [1] Hard X-ray nano-holotomography with a Fresnel zone plate
    Flenner, Silja
    Kubec, Adam
    David, Christian
    Storm, Malte
    Schaber, Clemens F.
    Vollrath, Fritz
    Mueller, Martin
    Greving, Imke
    Hagemann, Johannes
    OPTICS EXPRESS, 2020, 28 (25) : 37514 - 37525
  • [2] X-ray nano-holotomography reconstruction with simultaneous probe retrieval
    Nikitin, Viktor
    Carlsson, Marcus
    Guersoy, Doga
    Mokso, Rajmund
    Cloetens, Peter
    OPTICS EXPRESS, 2024, 32 (23): : 41905 - 41924
  • [3] Single-distance nano-holotomography with coded apertures
    Nikitin, Viktor
    Carlsson, Marcus
    Mokso, Rajmund
    Cloetens, Peter
    Gursoy, Doga
    OPTICS LETTERS, 2025, 50 (02) : 574 - 577
  • [4] Automated three-dimensional X-ray analysis using a dual-beam FIB
    Schaffer, Miroslava
    Wagner, Julian
    Schaffer, Bernhard
    Schmied, Mario
    Mulders, Hans
    ULTRAMICROSCOPY, 2007, 107 (08) : 587 - 597
  • [5] ANALYSIS OF THE ERROR IN INSTANTANEOUS VOID FRACTION MEASUREMENTS BY A DUAL-BEAM X-RAY TECHNIQUE
    MALAVIYA, BK
    LAHEY, RT
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1980, 34 (JUN): : 876 - 877
  • [6] Comparison of neutron and high-energy X-ray dual-beam radiography for air cargo inspection
    Liu, Y.
    Sowerby, B. D.
    Tickner, J. R.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (04) : 463 - 473
  • [7] X-ray in-line holography and holotomography at the NanoMAX beamline
    Kalbfleisch, Sebastian
    Zhang, Yuhe
    Kahnt, Maik
    Buakor, Khachiwan
    Langer, Max
    Dreier, Till
    Dierks, Hanna
    Stjarneblad, Philip
    Larsson, Emanuel
    Gordeyeva, Korneliya
    Chayanun, Lert
    Soderberg, Daniel
    Wallentin, Jesper
    Bech, Martin
    Villanueva-Perez, Pablo
    JOURNAL OF SYNCHROTRON RADIATION, 2022, 29 : 224 - 229
  • [8] Holotomography versus X-ray grating interferometry: A comparative study
    Zanette, I.
    Lang, S.
    Rack, A.
    Dominietto, M.
    Langer, M.
    Pfeiffer, F.
    Weitkamp, T.
    Mueller, B.
    APPLIED PHYSICS LETTERS, 2013, 103 (24)
  • [9] Femtosecond time-resolved X-ray absorption spectroscopy of liquid using a hard X-ray free electron laser in a dual-beam dispersive detection method
    Obara, Yuki
    Katayama, Tetsuo
    Ogi, Yoshihiro
    Suzuki, Takayuki
    Kurahashi, Naoya
    Karashima, Shutaro
    Chiba, Yuhei
    Isokawa, Yusuke
    Togashi, Tadashi
    Inubushi, Yuichi
    Yabashi, Makina
    Suzuki, Toshinori
    Misawa, Kazuhiko
    OPTICS EXPRESS, 2014, 22 (01): : 1105 - 1113
  • [10] Nanoscale optical memory based on dual-beam writing and dual-beam reading
    Wen, Jing
    Lamon, Simone
    Gu, Min
    ODS 2024: INDUSTRIAL OPTICAL DEVICES AND SYSTEMS, 2024, 13142