Performance Enhancement Analysis of Environmentally Friendly Refrigerants

被引:0
|
作者
Hsieh, Chun-Yu [1 ]
Yeh, Rong-Hua [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Marine Engn, Kaohsiung 805301, Taiwan
关键词
refrigerant; coefficient of performance; evaporation temperature; condensation temperature; global warming potential; ozone depletion potential; LOW-GWP REFRIGERANTS; ENERGY; R134A; SELECTION; SINGLE; R513A;
D O I
10.3390/pr12050904
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, -20, -40, and -60 degrees C and condensation temperatures of 30, 40, and 50 degrees C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 degrees C and -20 degrees C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = -40 degrees C and -60 degrees C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = -60 degrees C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = -40 degrees C and -60 degrees C. However, the growth rate of R717 ranks last for Teva = -60 degrees C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Performance analysis and development of a refrigeration cycle through various environmentally friendly refrigerants
    Saleh, Shahin
    Pirouzfar, Vahid
    Alihosseini, Afshar
    [J]. JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2019, 136 (04) : 1817 - 1830
  • [2] The impact of environmentally friendly refrigerants on heat pump efficiency
    Muszynski, Tomasz
    Andrzejczyk, Rafal
    Jakubowska, Blanka
    [J]. JOURNAL OF POWER TECHNOLOGIES, 2019, 99 (01): : 40 - 48
  • [3] Investigations of Environmentally Friendly Refrigerants' Phase Changes in Minichannels
    Bohdal, Tadeusz
    [J]. ROCZNIK OCHRONA SRODOWISKA, 2013, 15 : 107 - 126
  • [4] Impact of the mixing theories on the performance of ejector expansion refrigeration cycles for environmentally-friendly refrigerants
    Atmaca, Aye Ugurcan
    Erek, Aytunc
    Ekren, Orhan
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 211 - 225
  • [5] Experimental Study of Nucleate Boiling of Flammable, Environmentally Friendly Refrigerants
    Gil, Bartosz
    Fijalkowska, Beata
    [J]. ENERGIES, 2020, 13 (01)
  • [6] Experimental studies and estimates of the explosion limit of some environmentally friendly refrigerants
    Yang, Z
    Wu, T
    Li, XH
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 2005, 177 (03) : 613 - 626
  • [7] Flow boiling of environmentally friendly refrigerants inside a compact enhance tube
    Righetti, Giulia
    Longo, Giovanni A.
    Zilio, Claudio
    Mancin, Simone
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 104 : 344 - 355
  • [8] Experimental analysis of reciprocating compressor performance with eco-friendly refrigerants
    Bolaji, B. O.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2010, 224 (A6) : 781 - 786
  • [9] Analysis of an ejector with environment friendly refrigerants
    Selvaraju, A
    Mani, A
    [J]. APPLIED THERMAL ENGINEERING, 2004, 24 (5-6) : 827 - 838
  • [10] New environmentally friendly low-pressure refrigerants mini-channel
    Sikora, Malgorzata
    Bohdal, Tadeusz
    [J]. ARCHIVES OF THERMODYNAMICS, 2023, 44 (01) : 89 - 104