Application of Deep Learning for Real-Time Ablation Zone Measurement in Ultrasound Imaging

被引:0
|
作者
Zimmermann, Corinna [1 ]
Michelmann, Adrian [1 ]
Daniel, Yannick [1 ]
Enderle, Markus D. [1 ]
Salkic, Nermin [1 ,2 ]
Linzenbold, Walter [1 ]
机构
[1] Erbe Elektromed GmbH, D-72072 Tubingen, Germany
[2] Univ Tuzla, Fac Med, Tuzla 75000, Bosnia & Herceg
关键词
radiofrequency ablation; ultrasonography; artificial intelligence; image processing; computer-assisted; ablation techniques; RADIOFREQUENCY ABLATION; MICROWAVE ABLATION; LIVER; LENGTH; ACCURACY; TISSUE;
D O I
10.3390/cancers16091700
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: The accurate delineation of ablation zones (AZs) is crucial for assessing radiofrequency ablation (RFA) therapy's efficacy. Manual measurement, the current standard, is subject to variability and potential inaccuracies. Aim: This study aims to assess the effectiveness of Artificial Intelligence (AI) in automating AZ measurements in ultrasound images and compare its accuracy with manual measurements in ultrasound images. Methods: An in vitro study was conducted using chicken breast and liver samples subjected to bipolar RFA. Ultrasound images were captured every 15 s, with the AI model Mask2Former trained for AZ segmentation. The measurements were compared across all methods, focusing on short-axis (SA) metrics. Results: We performed 308 RFA procedures, generating 7275 ultrasound images across liver and chicken breast tissues. Manual and AI measurement comparisons for ablation zone diameters revealed no significant differences, with correlation coefficients exceeding 0.96 in both tissues (p < 0.001). Bland-Altman plots and a Deming regression analysis demonstrated a very close alignment between AI predictions and manual measurements, with the average difference between the two methods being -0.259 and -0.243 mm, for bovine liver and chicken breast tissue, respectively. Conclusion: The study validates the Mask2Former model as a promising tool for automating AZ measurement in RFA research, offering a significant step towards reducing manual measurement variability.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Real-time spatial compound imaging: Application to breast, vascular, and musculoskeletal ultrasound
    Entrekin, RR
    Porter, BA
    Sillesen, HH
    Wong, AD
    Cooperberg, PL
    Fix, CH
    SEMINARS IN ULTRASOUND CT AND MRI, 2001, 22 (01) : 50 - 64
  • [32] GPU-Based Real-Time Approximation of the Ablation Zone for Radiofrequency Ablation
    Rieder, Christian
    Kroeger, Tim
    Schumann, Christian
    Hahn, Horst K.
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2011, 17 (12) : 1812 - 1821
  • [33] Fluorescence Imaging for Real-Time Monitoring of High-Intensity Focused Ultrasound Cardiac Ablation
    Cheri X. Deng
    Fujian Qu
    Vladimir P. Nikolski
    Yun Zhou
    Igor R. Efimov
    Annals of Biomedical Engineering, 2005, 33 : 1352 - 1359
  • [34] Real-time Control of Bulk Ultrasound Thermal Ablation Using Echo Decorrelation Imaging Feedback
    Abbass, Mohamed A.
    Garbo, Allison-Joy
    Mahalingam, Neeraja
    Killin, Jakob K.
    Mast, T. Douglas
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [35] Fluorescence imaging for real-time monitoring of high-intensity focused ultrasound cardiac ablation
    Deng, CRX
    Qu, FJ
    Nikolski, VP
    Zhou, Y
    Efimov, IR
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (10) : 1352 - 1359
  • [36] Real-time polarization measurement based on spatially modulated polarimeter and deep learning
    Weng, Jianyu
    Gao, Chao
    Lei, Bing
    RESULTS IN PHYSICS, 2023, 46
  • [37] Real-time imaging in left atrial mapping and ablation
    Daccarett, Marcos
    Oakes, Robert
    Segerson, Nathan M.
    Windfelder, Jessiciah
    Marrouche, Nassir F.
    FUTURE CARDIOLOGY, 2008, 4 (03) : 253 - 260
  • [38] Real-time categorization of driver's gaze zone using the deep learning techniques
    Choi, In-Ho
    Hong, Sung Kyung
    Kim, Yong-Guk
    2016 INTERNATIONAL CONFERENCE ON BIG DATA AND SMART COMPUTING (BIGCOMP), 2016, : 143 - 148
  • [39] Ultrasound Contrast Agent Imaging: Real-time Imaging of the Superharmonics
    Peruzzini, D.
    Viti, J.
    Tortoli, P.
    Verweij, M. D.
    de Jong, N.
    Vos, H. J.
    RECENT DEVELOPMENTS IN NONLINEAR ACOUSTICS, 2015, 1685
  • [40] A Deep Learning Approach to Real-Time Recovery for Compressive Hyper Spectral Imaging
    Li, Ruimin
    Zeng, Yang
    Wen, Desheng
    Song, Zongxi
    2017 IEEE 3RD INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC), 2017, : 1030 - 1034