Polymer composite fiber-optic Fabry-Perot cavity sensor based on Ti3C2TX MXene enhanced photothermal effect for low-concentration bilirubin detection

被引:0
|
作者
Zhang, Yangyuan [1 ]
Miao, Yinping [1 ]
Chen, Xuanyi [1 ]
Bai, Yangbo [1 ]
Yao, Jianquan [2 ]
机构
[1] Tianjin Univ Technol, Sch Integrated Circuit Sci & Engn, Tianjin Key Lab Film Elect & Commun Device, Tianjin 300384, Peoples R China
[2] Tianjin Univ, Inst Laser & Optoelect, Coll Precis Instrument & Optoelect Engn, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Absorption spectroscopy - Composite materials - Diagnosis - Fabry-Perot interferometers - Neurodegenerative diseases - Single mode fibers;
D O I
10.1063/5.0215454
中图分类号
O59 [应用物理学];
学科分类号
摘要
The World Health Statistics 2023, as presented by the World Health Organization (WHO), underscores a significant global health concern: 73% of global mortality is attributed to chronic diseases. Within the domain of medical diagnostics, serum bilirubin levels serve as a critical biomarker for identifying several prevalent chronic conditions in adult and geriatric populations. In this study, a polymer composite fiber-optic Fabry-P & eacute;rot interferometer is prepared, wherein the reflective surfaces are, respectively, constituted by polyurethane (PU), with characteristics marked by high thermal responsiveness and rapid thermal transfer rates, and a single-mode fiber. Subsequently, the outer surface of the PU reflective end undergoes deposition with Ti3C2TX MXene material, which has the capability to enhance the adsorption of bilirubin molecules. This work proposes a detection method using the photothermal effect of bilirubin. When the sensor is operational, bilirubin generates a thermal effect under 405 nm laser irradiation. The Fabry-P & eacute;rot air cavity rapidly expands with the increased heat absorption, leading to shifts in the interference spectrum, which enables the effective detection of low concentrations of bilirubin within the serum. The experimental results indicate that the sensor exhibits a sensitivity of 7.51 [nm/(mu mol/L)] and a detection limit of a mere 0.002 19 mu mol/L within the linear dynamic range of 1-10 mu mol/L. Furthermore, a tenfold improvement is observed when compared to the previously reported lowest detection limit. The sensor delineated herein is characterized by heightened sensitivity, minimal detection limit, rapid response time, and substantial robustness, rendering it suitable for potential applications in the early diagnosis and prognosis of chronic diseases such as Alzheimer's disease.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Ti3C2Tx MXene paper-based flexible wearable pressure sensor with wide pressure detection range for human motion detection
    Wei, Chengtian
    Xu, Yisen
    Hu, Yang
    Zhang, Qiaoqiao
    Wei, Ning
    Zeng, Wei
    Wu, Ranyun
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1017
  • [32] An enhanced SPR optical fiber biosensor using Ti3C2Tx MXene/AuNPs for label-free and sensitive detection of human IgG
    Zhu, Jiayi
    Zhao, Chao
    Xia, Binyun
    Wang, Ning
    Chen, Xi
    Jing, Xinyue
    Chen, Minxuan
    Xu, Xinrui
    NANOSCALE, 2024, 16 (39) : 18477 - 18487
  • [33] Ti3C2Tx MXene Paper-Based Wearable and Degradable Pressure Sensor for Human Motion Detection and Encrypted Information Transmission
    Liu, Hailian
    Zhang, Qi
    Yang, Ning
    Jiang, Xuezheng
    Wang, Fang
    Yan, Xin
    Zhang, Xuenan
    Zhao, Yong
    Cheng, Tonglei
    ACS APPLIED MATERIALS & INTERFACES, 2023, 15 (37) : 44554 - 44562
  • [34] Intrinsic MXene-Ti3C2Tx enhanced high sensitivity Mach-Zehnder interferometric microstructured optic fiber temperature sensor
    Wu, Yuhang
    Feng, Yue
    Liu, Xin
    Shen, Tao
    Zhang, Hanmei
    OPTICAL FIBER TECHNOLOGY, 2023, 80
  • [35] Co3O4@PEI/Ti3C2Tx MXene nanocomposites for a highly sensitive NOx gas sensor with a low detection limit
    Sun, Baihe
    Lv, He
    Liu, Zhuo
    Wang, Jue
    Bai, Xue
    Zhang, Yang
    Chen, Junkun
    Kan, Kan
    Shi, Keying
    JOURNAL OF MATERIALS CHEMISTRY A, 2021, 9 (10) : 6335 - 6344
  • [36] W18O49/Ti3C2Tx Mxene nanocomposites for highly sensitive acetone gas sensor with low detection limit
    Sun, Shibin
    Wang, Mingwei
    Chang, Xueting
    Jiang, Yingchang
    Zhang, Dongzhi
    Wang, Dongsheng
    Zhang, Yuliang
    Lei, Yanhua
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 304 (304):
  • [37] Covalently grafting multihydroxy hyperbranched polymer on the surface of Ti3C2Tx MXene with remarkably enhanced colloidal stability and functionality for photothermal therapy (vol 47, 104214, 2024)
    Yang, Chen
    Zeng, Hai
    Zhou, Li
    SURFACES AND INTERFACES, 2024, 48
  • [38] PANI/Ti3C2Tx composite nanofiber-based flexible conductometric sensor for the detection of NH3 at room temperature
    Yang, Ruyi
    Zhang, Jinniu
    Liu, Jia
    Li, Gang
    Qiao, Yu
    Zhang, Xinyi
    Gao, Jianzhi
    Lu, Hongbing
    SENSORS AND ACTUATORS B-CHEMICAL, 2023, 392
  • [39] Ratiometric electrochemical sensor based on methylene blue-functionalized Ti3C2Tx MXene/Pt nanoparticle composites for reliable detection of carbendazim
    Wang, Ying
    Liu, Xiaohong
    Tan, Hao
    Yang, Yiming
    Wang, Xi
    Zhu, Chengxi
    JOURNAL OF ALLOYS AND COMPOUNDS, 2025, 1013