A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis

被引:0
|
作者
Laursen, Jakob [1 ]
Christensen, Amalie [1 ]
Egsgaard, Simon [1 ]
Sondergaard, Klaus [2 ]
Mechlenburg, Inger [3 ,4 ]
Brincks, John [1 ]
机构
[1] VIA Univ Coll, Res Ctr Prevent & Hlth Promot, Hedeager 2, DK-8200 Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Rheumatol, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Orthopaed Surg, Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
关键词
Systemic sclerosis; physical functional performance; reliability; construct validity;
D O I
10.1080/09593985.2024.2373392
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective This study seeks to assess the reliability and construct validity of the 1-minute sit-to-stand test as an efficient tool for evaluating the functional capacity of individuals with systemic sclerosis, considering its time and space effectiveness. Methods This cross-sectional study recruited forty-nine individuals with systemic sclerosis from a university hospital in Denmark. The 1-minute sit-to-stand test was conducted twice on the same day, with an interval of approximately 10 to 15 minutes between administrations, followed by a single administration of the 6-minute walk test. Reliability and validity were estimated using Bland-Altman statistics, intraclass correlation coefficient (ICC2,1), paired t-test, and Spearman's rank correlation coefficient (rho). Results The 1-minute sit-to-stand test exhibited excellent test-retest reliability with an ICC2,1 (CI) of 0.97 (0.95-0.99). The minimal metrically detectable change between separate measures on a subject for the difference in the measures to be considered real at the 95% confidence level was 2.9 repetitions and 11%, respectively. A learning effect of one repetition was observed between repeated measures. High construct validity was observed between the 1-minute sit-to-stand and 6-minute walk test (rho = 0.78, p < .001). Conclusions This study demonstrates the 1-minute sit-to-stand test as highly reliable, with an 11% change indicating a true outcome change. It also demonstrates robust construct validity compared to the 6-minute walk test. The 1-minute sit-to-stand test appears feasible for assessing functional capacity in well-functioning individuals with systemic sclerosis, but prior familiarization with the task is recommended, as a small learning effect was observed with one repetition.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Reliability of the 1-minute sit-to-stand test in chronic obstructive pulmonary disease
    Thu, Hang Nguyen Thi
    Le Khac, Bao
    Poncin, William
    [J]. ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2024, 67 (07)
  • [2] Test-Retest Reliability and Validity of 1-Minute Sit-to-Stand Test in Patients With Chronic Heart Failure
    Tanriverdi, Aylin
    Kahraman, Buse Ozcan
    Ozpelit, Ebru
    Savci, Sema
    [J]. HEART LUNG AND CIRCULATION, 2023, 32 (04): : 518 - 524
  • [3] Assessment of Validity and Reliability of the 1-Minute Sit-to-Stand Test to Measure the Heart Rate Response to Exercise in Healthy Children
    Reychler, Gregory
    Audag, Nicolas
    Mestre, Natalia Morales
    Caty, Gilles
    [J]. JAMA PEDIATRICS, 2019, 173 (07) : 692 - 693
  • [4] A multicentre validation of the 1-minute sit-to-stand test in COPD patients
    Crook, Sarah
    Schultz, Konrad
    Lehbert, Nicola
    Busching, Gilbert
    Jelusic, Danijel
    Keusch, Stephan
    Wittmann, Michael
    Schuler, Michael
    Radtke, Thomas
    Turk, Alexander
    Frey, Martin
    Puhan, Milo
    Frei, Anja
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [5] Reference values for the 1-minute sit-to-stand test for the Argentine population
    Larrateguy, Santiago
    Burgos, Santiago
    Iglesias, Rocio
    Carrizo, Laura
    Cestari, Martin
    Saavedra, Santiago
    Larrateguy, Luis
    Otto-Yanez, Matias
    Mazzucco, Guillermo
    Gimeno-Santos, Elena
    Torres-Castro, Rodrigo
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [6] Baseline determinants of 1-minute sit-to-stand test performance in COPD patients
    Crook, Sarah
    Frei, Anja
    Yu, Tsung
    Ter Riet, Gerben
    Puhan, Milo
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [7] Role of 1-minute sit-to-stand in the diagnosis of Long COVID
    Faria, N.
    Oliveira, T.
    Pinto, P.
    Almeida, V.
    Fernandes, M. J.
    Carvalho, R.
    Sucena, M.
    Gomes, J.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [8] The 1-Minute Sit-to-Stand Test in Lung Transplant Candidates: An Alternative to the 6-Minute Walk Test
    Kohlbrenner, Dario
    Benden, Christian
    Radtke, Thomas
    [J]. RESPIRATORY CARE, 2020, 65 (04) : 437 - 443
  • [9] Reliability of remote 1-minute sit-to-stand test to measure physical capacity in patients with chronic respiratory diseases
    Larrateguy, Santiago
    Otto-Yanes, Matias
    Bogado, Juan
    Larrateguy, Luis
    Blanco, Isabel
    Gimeno-Santos, Elena
    Torres-Castro, Rodrigo
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2023, 62
  • [10] Is the 1-minute sit-to-stand test related to respiratory muscle strength in patients with COPD?
    Miranda, Sara
    Machado, Ana
    Melro, Helder
    Oliveira, Ana
    Valente, Carla
    Marques, Alda Sofia Pires De Dias
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2017, 50