Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study

被引:0
|
作者
Azzi, A. [1 ]
Hidayat, R. [1 ]
Rosa, A. [1 ]
Lubis, L. E. [1 ]
机构
[1] Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Jl Margonda Raya, Depok 16424, Indonesia
关键词
3D rotational angiography; CTDI; Monte Carlo; CBCT; CONE-BEAM CT; DOSIMETRY;
D O I
10.55981/aij.2024.1307
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study aims to verify the weighted Computed Tomography Dose Index (CTDIw) coefficients of 3D rotational angiography (3DRA) procedure using Monte Carlo simulation. The Monte Carlo simulation EGSnrc usercode was employed for 3D dose simulations of the rotational angiography procedure. A virtual phantom resembles the head CTDI phantom was constructed, with a diameter of 16 cm and a density resembling polymethyl methacrylate (1.13 g/cm 3 ). A series of virtual phantoms consisting of 5 images with ionization chamber detectors at the center position, 12 o'clock, 9 o'clock, 6 o'clock, and 3 o'clock were acquired. Simulations were performed with photon sources of 70 and 109 kVp for 200-degree x-ray tube rotation. The field of view was divided into narrow, wide, and full beam with diameters of 1.7 cm; 4.9 cm; and 8.6 cm, respectively. The simulated doses at the ionization chamber were processed into weighting factor for weighted CTDI and compared with direct measurements. The dose ratio between peripheral and center positions for 360 degrees CBCT and 200 degrees 3DRA was 1:1 and 1:3 in this study. The weighting factors for 3DRA were determined as CTDIcenter = 1 / 4 and CTDIperiphery = 3 / 4 . The measured average percentage difference of CTDIw between our weighted factor and conventional CTDIw was 1.75 % (-3.99 % to 6.08 %). The x-ray tube position of 3DRA impacted the accuracy of weighting factor of CTDIw, with implications for the proposed weighting factor (Wcenter = 1 / 4 and Wperiphery = 3 / 4 ) when using a 3DRA machine. (c) 2024 Atom Indonesia. All rights reserved
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [1] New weighting factor of weighted CTDI equation for PMMA phantom diameter from 8 to 40 cm: A Monte Carlo study
    Haba, Tomonobu
    Koyama, Shuji
    Kinomura, Yutaka
    Ida, Yoshihiro
    Kobayashi, Masanao
    MEDICAL PHYSICS, 2017, 44 (12) : 6603 - 6609
  • [2] MONTE-CARLO STUDY OF 3D VESICLES
    ORLANDINI, E
    TESI, MC
    PHYSICA A, 1992, 185 (1-4): : 160 - 165
  • [3] 3D Ising nonuniversality: A Monte Carlo study
    Schulte, M
    Drope, C
    INTERNATIONAL JOURNAL OF MODERN PHYSICS C, 2005, 16 (08): : 1217 - 1224
  • [4] Artifacts in 3D rotational angiography. An experimental study
    Hagen, G
    Lindgren, PG
    Jangland, L
    Magnusson, P
    Magnusson, A
    ACTA RADIOLOGICA, 2005, 46 (01) : 32 - 36
  • [5] 3D CT Angiography for Detection of Intracranial Aneurysms: Comparison with 3D Rotational Angiography
    Li, Qi
    Li, Jialun
    Lv, Fajin
    Xie, Peng
    NEUROLOGY, 2010, 74 (09) : A225 - A225
  • [6] 3D rotational angiography of transplanted kidneys
    Hagen, G
    Wadström, J
    Magnusson, A
    ACTA RADIOLOGICA, 2003, 44 (02) : 193 - 198
  • [7] Fully 3D Monte Carlo reconstruction in SPECT: a feasibility study
    Lazaro, D
    El Bitar, Z
    Breton, V
    Hill, D
    Buvat, I
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3739 - 3754
  • [8] A multicanonical Monte Carlo study of the 3D ±J spin glass
    Hatano, N
    Gubernatis, JE
    PROGRESS OF THEORETICAL PHYSICS SUPPLEMENT, 2000, (138): : 442 - 447
  • [9] Bond dilution in the 3D Ising model: a Monte Carlo study
    P. E. Berche
    C. Chatelain
    B. Berche
    W. Janke
    The European Physical Journal B - Condensed Matter and Complex Systems, 2004, 38 : 463 - 474
  • [10] Bond dilution in the 3D ising model: a Monte Carlo study
    Berche, PE
    Chatelain, C
    Berche, B
    Janke, W
    EUROPEAN PHYSICAL JOURNAL B, 2004, 38 (03): : 463 - 474