Weighted CTDI Equation for 3D Rotational Angiography: A Monte Carlo Study

被引:0
|
作者
Azzi, A. [1 ]
Hidayat, R. [1 ]
Rosa, A. [1 ]
Lubis, L. E. [1 ]
机构
[1] Univ Indonesia, Fac Math & Nat Sci, Dept Phys, Jl Margonda Raya, Depok 16424, Indonesia
关键词
3D rotational angiography; CTDI; Monte Carlo; CBCT; CONE-BEAM CT; DOSIMETRY;
D O I
10.55981/aij.2024.1307
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study aims to verify the weighted Computed Tomography Dose Index (CTDIw) coefficients of 3D rotational angiography (3DRA) procedure using Monte Carlo simulation. The Monte Carlo simulation EGSnrc usercode was employed for 3D dose simulations of the rotational angiography procedure. A virtual phantom resembles the head CTDI phantom was constructed, with a diameter of 16 cm and a density resembling polymethyl methacrylate (1.13 g/cm 3 ). A series of virtual phantoms consisting of 5 images with ionization chamber detectors at the center position, 12 o'clock, 9 o'clock, 6 o'clock, and 3 o'clock were acquired. Simulations were performed with photon sources of 70 and 109 kVp for 200-degree x-ray tube rotation. The field of view was divided into narrow, wide, and full beam with diameters of 1.7 cm; 4.9 cm; and 8.6 cm, respectively. The simulated doses at the ionization chamber were processed into weighting factor for weighted CTDI and compared with direct measurements. The dose ratio between peripheral and center positions for 360 degrees CBCT and 200 degrees 3DRA was 1:1 and 1:3 in this study. The weighting factors for 3DRA were determined as CTDIcenter = 1 / 4 and CTDIperiphery = 3 / 4 . The measured average percentage difference of CTDIw between our weighted factor and conventional CTDIw was 1.75 % (-3.99 % to 6.08 %). The x-ray tube position of 3DRA impacted the accuracy of weighting factor of CTDIw, with implications for the proposed weighting factor (Wcenter = 1 / 4 and Wperiphery = 3 / 4 ) when using a 3DRA machine. (c) 2024 Atom Indonesia. All rights reserved
引用
收藏
页码:43 / 48
页数:6
相关论文
共 50 条
  • [21] Fenestrations of Intracranial Arteries Detected with 3D Rotational Angiography
    van Rooij, S. B. T.
    van Rooij, W. J.
    Sluzewski, M.
    Sprengers, M. E. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (07) : 1347 - 1350
  • [22] Rotational angiography and 3D modeling in diagnostics and treatment of CHD
    Karapetyan, N.
    Grigoryan, M. V.
    EUROPEAN HEART JOURNAL, 2017, 38 : 693 - 693
  • [23] Optimizing 3D Rotational Angiography for Congenital Cardiac Catheterization
    Salavitabar, Arash
    Boe, Brian A.
    Berman, Darren P.
    Harrison, Andrew
    Swinning, Jason
    Baptista, Kristine
    Eisner, Mariah
    Bai, Shasha
    Armstrong, Aimee K.
    PEDIATRIC CARDIOLOGY, 2023, 44 (01) : 132 - 140
  • [24] Optimizing 3D Rotational Angiography for Congenital Cardiac Catheterization
    Arash Salavitabar
    Brian A. Boe
    Darren P. Berman
    Andrew Harrison
    Jason Swinning
    Kristine Baptista
    Mariah Eisner
    Shasha Bai
    Aimee K. Armstrong
    Pediatric Cardiology, 2023, 44 : 132 - 140
  • [25] Kinetic Monte Carlo study of mixed 1D/3D defect migration
    Heinisch, H.L.
    Singh, B.N.
    Golubov, S.I.
    Journal of Computer-Aided Materials Design, 1999, 6 (02): : 277 - 282
  • [26] A kinetic Monte Carlo study of mixed 1D/3D defect migration
    Heinisch, HL
    Singh, BN
    Golubov, SI
    JOURNAL OF COMPUTER-AIDED MATERIALS DESIGN, 1999, 6 (2-3): : 277 - 282
  • [27] Anisotropic Schrodinger Equation Quantum Corrections for 3D Monte Carlo Simulations of Nanoscale Multigate Transistors
    Elmessary, Muhammad A.
    Nagy, Daniel
    Aldegunde, Manuel
    Lindberg, Jari
    Dettmer, Wulf
    Peric, Djordje
    Garcia-Loureiro, Antonio J.
    Kalna, Karol
    18TH INTERNATIONAL WORKSHOP ON COMPUTATIONAL ELECTRONICS (IWCE 2015), 2015,
  • [28] Weighted energy decay for 3D wave equation
    Kopylova, E. A.
    ASYMPTOTIC ANALYSIS, 2009, 65 (1-2) : 1 - 16
  • [29] Investigation of the 3D ANNNI Model by Monte Carlo Methods
    Murtazaev, A. K.
    Ibaev, J. G.
    Abuev, Ya. K.
    MAGNETISM AND MAGNETIC MATERIALS, 2009, 152-153 : 575 - 578
  • [30] On the recrystallization kinetics of 3D Potts Monte Carlo simulations
    Fjeldberg, E.
    Marthinsen, K.
    RECRYSTALLIZATION AND GRAIN GROWTH IV, 2012, 715-716 : 959 - 964