Anatomical Reference of the Femur after Distal Resection Is Reliable for Rotational Alignment in Total Knee Arthroplasty

被引:0
|
作者
Kim, Seong Hwan [1 ]
Park, Yong-Beom [2 ]
Choi, Gil-Won [1 ]
Lee, Han-Jun [1 ]
机构
[1] Chung Ang Univ Hosp, Dept Orthopaed Surg, 102 Heukseok Ro, Seoul 06973, South Korea
[2] Chung Ang Univ, Coll Med, Gwangmyeong Hosp, Dept Orthopaed Surg, 110 Deokan Ro, Gwangmyeong Si 14353, South Korea
来源
JOURNAL OF PERSONALIZED MEDICINE | 2024年 / 14卷 / 06期
关键词
total knee arthroplasty; distal femur; rotational alignment; femoral rotation; anatomy; FEMORAL COMPONENT ROTATION; CORONAL PLANE ALIGNMENT; ANTHROPOMETRIC MEASUREMENTS; EXTERNAL ROTATION; FOLLOW-UP; AXIS; CLASSIFICATION; VARIABILITY; MORPHOMETRY; CONDYLES;
D O I
10.3390/jpm14060663
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
The rotational alignment of the femoral component in total knee arthroplasty (TKA) is considered an important factor, but it is still difficult to assess intraoperatively. This study was conducted to identify anatomical parameters for femoral rotational alignment. A total of 204 patients who underwent primary TKA between 2015 and 2019 were enrolled. The femoral lateral (FLAP) and femoral medial anteroposterior (FMAP) lengths were measured as the widest lengths in the anteroposterior (AP) axis after distal femoral resection. The difference between FLAP and FMAP was defined as dFAP. The concordance correlation coefficient (CCC) was assessed for agreement between the cTEA-PCA and the value of femoral rotation using the linear regression analysis equation. HKA, FLAP, FMAP, and dFAP were significantly associated with femoral rotational alignment. The prediction equation combining the novel intraoperative anatomical references showed improved association with rotational alignment. If dFAP was 6.0 mm, the femoral rotation angle was calculated as 4.9 degrees using this univariate regression equation. The CCC was 0.483, indicating moderate agreement. The dFAP showed an association with distal femoral rotational alignment. A 6 mm dFAP could be a reference for around 5 degrees of femoral rotation. The equation developed in this study may be a reliable tool for intraoperative distal femoral rotational alignment.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Floating total knee: Ipsilateral peroprosthetic fractures of the distal femur and proximal tibia after total knee arthroplasty
    Jeong, GK
    Pettrone, SK
    Liporace, FA
    Meere, PA
    JOURNAL OF ARTHROPLASTY, 2006, 21 (01): : 138 - 140
  • [32] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Joong Il Kim
    Jak Jang
    Ki Woong Lee
    Hyuk Soo Han
    Sahnghoon Lee
    Myung Chul Lee
    BMC Musculoskeletal Disorders, 18
  • [33] The femoral anterior tangent line could serve as a reliable alternative reference axis for distal femoral rotational alignment in total knee arthroplasty: an MRI-based study
    Li, Shuzhen
    Deng, Haiquan
    Jiang, Lianjian
    Liang, Haibo
    Sun, Jianchao
    Xu, Youjia
    FRONTIERS IN SURGERY, 2024, 11
  • [34] Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty
    Kim, Joong Il
    Jang, Jak
    Lee, Ki Woong
    Han, Hyuk Soo
    Lee, Sahnghoon
    Lee, Myung Chul
    BMC MUSCULOSKELETAL DISORDERS, 2017, 18
  • [35] A Comparison of Classical and Anatomical Total Knee Alignment Methods in Robotic Total Knee Arthroplasty Classical and Anatomical Knee Alignment Methods in TKA
    Yim, Ji-Hyun
    Song, Eun-Kyoo
    Khan, Mohammad Shahnawaz
    Sun, Zhen Hui
    Seon, Jong-Keun
    JOURNAL OF ARTHROPLASTY, 2013, 28 (06): : 932 - 937
  • [36] Distal Femur Locking Plates Fit Poorly Before and After Total Knee Arthroplasty
    Campbell, Sean T.
    Bosch, Liam C.
    Swinford, Steven
    Amanatullah, Derek F.
    Bishop, Julius A.
    Gardner, Michael J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (05) : 239 - 243
  • [37] Changes in knee alignment after total knee arthroplasty
    Matsuda, S
    Miura, H
    Nagamine, R
    Urabe, K
    Harimaya, K
    Matsunobu, T
    Iwamoto, Y
    JOURNAL OF ARTHROPLASTY, 1999, 14 (05): : 566 - 570
  • [38] Influence of Distal Reference Point of the Tibial Mechanical Axis on the Ankle and Hindlimb Alignment Change after Total Knee Arthroplasty
    Kikuchi, Kenichi
    Nakano, Naoki
    Ishida, Kazunari
    Kuroda, Yuichi
    Hayashi, Shinya
    Tsubosaka, Masanori
    Kamenaga, Tomoyuki
    Matsushita, Takehiko
    Kuroda, Ryosuke
    Matsumoto, Tomoyuki
    JOURNAL OF KNEE SURGERY, 2024, 37 (06) : 409 - 415
  • [39] The extensor hallucis longus tendon as the distal reference point in total knee arthroplasty and tibial alignment
    Bilgen, Omer
    Bilgen, Sadik
    Ermutlu, Cenk
    Goksel, Ferdi
    Salar, Necmettin
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2014, 48 (03) : 271 - 275
  • [40] New anatomical landmark for rotational assessment of total knee arthroplasty
    Cretu, Bogdan
    Serban, Bogdan
    Iordache, Sergiu
    Cursaru, Adrian
    Costache, Mihai
    Cirstoiu, Catalin
    ROMANIAN JOURNAL OF MILITARY MEDICINE, 2022, 125 (03) : 458 - 463