Photonic Nanochains for Continuous Glucose Monitoring in Physiological Environment

被引:0
|
作者
Shi, Gongpu [1 ]
Si, Luying [1 ]
Cai, Jinyang [2 ]
Jiang, Hao [1 ]
Liu, Yun [1 ]
Luo, Wei [2 ]
Ma, Huiru [3 ]
Guan, Jianguo [1 ,4 ]
机构
[1] Wuhan Univ Technol, Int Sch Mat Sci & Engn, State Key Lab Adv Technol Mat Synth & Proc, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Sch Mat Sci & Engn, Wuhan 430070, Peoples R China
[3] Wuhan Univ Technol, Sch Chem Chem Engn & Life Sci, Wuhan 430070, Peoples R China
[4] Wuhan Inst Photochem & Technol, 7 North Bingang Rd, Wuhan 430083, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose monitor; responsive photonic nanochains; colorimetric sensor; physiological environment; HYDROGEL; CRYSTAL; BEARING;
D O I
10.3390/nano14110964
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diabetes is a common disease that seriously endangers human health. Continuous glucose monitoring (CGM) is important for the prevention and treatment of diabetes. Glucose-sensing photonic nanochains (PNCs) have the advantages of naked-eye colorimetric readouts, short response time and noninvasive detection of diabetes, showing immense potential in CGM systems. However, the developed PNCs cannot disperse in physiological environment at the pH of 7.4 because of their poor hydrophilicity. In this study, we report a new kind of PNCs that can continuously and reversibly detect the concentration of glucose (Cg) in physiological environment at the pH of 7.4. Polyacrylic acid (PAA) added to the preparation of PNCs forms hydrogen bonds with polyvinylpyrrolidone (PVP) in Fe3O4@PVP colloidal nanoparticles and the hydrophilic monomer N-2-hydroxyethyl acrylamide (HEAAm), which increases the content of PHEAAm in the polymer shell of prepared PNCs. Moreover, 4-(2-acrylamidoethylcarbamoyl)-3-fluorophenylboronic acid (AFPBA), with a relatively low pKa value, is used as the glucose-sensing monomer to further improve the hydrophilicity and glucose-sensing performances of PNCs. The obtained Fe3O4@(PVP-PAA)@poly(AFPBA-co-HEAAm) PNCs disperse in artificial serum and change color from yellow-green to red when Cg increases from 3.9 mM to 11.4 mM, showing application potential for straightforward CGM.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Continuous monitoring of blood glucose
    Robert, JJ
    HORMONE RESEARCH, 2002, 57 : 81 - 84
  • [42] Continuous Glucose Monitoring in 2013
    Battelino, Tadej
    Bode, Bruce W.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2014, 16 : S11 - S16
  • [43] The Future of Continuous Glucose Monitoring
    Garg, Satish K.
    Akturk, Halis K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2017, 19 : S1 - S2
  • [44] A glucose sensor protein for continuous glucose monitoring
    Veetil, Jithesh V.
    Jin, Sha
    Ye, Kaiming
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1650 - 1655
  • [45] Is the Accuracy and Lag of Continuous Glucose Monitoring Systems in Measuring Physiological Changes in Blood Glucose Levels Affected by Sensor Life?
    Iscoe, Katherine E.
    Davey, Raymond J.
    Fournier, Paul A.
    DIABETES, 2011, 60 : A65 - A65
  • [46] Lipophilic Magnetic Photonic Nanochains for Practical Anticounterfeiting
    Li, Gang
    Luo, Wei
    Che, Zhiyuan
    Pu, YuYang
    Deng, Peng
    Shi, Lei
    Ma, Huiru
    Guan, Jianguo
    SMALL, 2022, 18 (21)
  • [47] Assembling magnetite nanoparticles to fixed photonic nanochains
    Wang, Mingsheng
    Yin, Yadong
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 243
  • [48] INVIVO CONTINUOUS MONITORING OF GLUCOSE BY MICRODIALYSIS AND A GLUCOSE BIOSENSOR
    MASCINI, M
    MOSCONE, D
    BERNARDI, L
    SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) : 143 - 145
  • [50] Continuous glucose monitoring and intrapersonal variability in fasting glucose
    Shilo, Smadar
    Keshet, Ayya
    Rossman, Hagai
    Godneva, Anastasia
    Talmor-Barkan, Yeela
    Aviv, Yaron
    Segal, Eran
    NATURE MEDICINE, 2024, 30 (05) : 1424 - +