Photonic Nanochains for Continuous Glucose Monitoring in Physiological Environment

被引:0
|
作者
Shi, Gongpu [1 ]
Si, Luying [1 ]
Cai, Jinyang [2 ]
Jiang, Hao [1 ]
Liu, Yun [1 ]
Luo, Wei [2 ]
Ma, Huiru [3 ]
Guan, Jianguo [1 ,4 ]
机构
[1] Wuhan Univ Technol, Int Sch Mat Sci & Engn, State Key Lab Adv Technol Mat Synth & Proc, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Sch Mat Sci & Engn, Wuhan 430070, Peoples R China
[3] Wuhan Univ Technol, Sch Chem Chem Engn & Life Sci, Wuhan 430070, Peoples R China
[4] Wuhan Inst Photochem & Technol, 7 North Bingang Rd, Wuhan 430083, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose monitor; responsive photonic nanochains; colorimetric sensor; physiological environment; HYDROGEL; CRYSTAL; BEARING;
D O I
10.3390/nano14110964
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diabetes is a common disease that seriously endangers human health. Continuous glucose monitoring (CGM) is important for the prevention and treatment of diabetes. Glucose-sensing photonic nanochains (PNCs) have the advantages of naked-eye colorimetric readouts, short response time and noninvasive detection of diabetes, showing immense potential in CGM systems. However, the developed PNCs cannot disperse in physiological environment at the pH of 7.4 because of their poor hydrophilicity. In this study, we report a new kind of PNCs that can continuously and reversibly detect the concentration of glucose (Cg) in physiological environment at the pH of 7.4. Polyacrylic acid (PAA) added to the preparation of PNCs forms hydrogen bonds with polyvinylpyrrolidone (PVP) in Fe3O4@PVP colloidal nanoparticles and the hydrophilic monomer N-2-hydroxyethyl acrylamide (HEAAm), which increases the content of PHEAAm in the polymer shell of prepared PNCs. Moreover, 4-(2-acrylamidoethylcarbamoyl)-3-fluorophenylboronic acid (AFPBA), with a relatively low pKa value, is used as the glucose-sensing monomer to further improve the hydrophilicity and glucose-sensing performances of PNCs. The obtained Fe3O4@(PVP-PAA)@poly(AFPBA-co-HEAAm) PNCs disperse in artificial serum and change color from yellow-green to red when Cg increases from 3.9 mM to 11.4 mM, showing application potential for straightforward CGM.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Continuous glucose monitoring and pumps
    Cohen, Neale
    AUSTRALIAN FAMILY PHYSICIAN, 2015, 44 (05) : 284 - 287
  • [22] The Future of Continuous Glucose Monitoring
    Garg, Satish K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S1 - S3
  • [23] Continuous Glucose Monitoring in 2018
    Bode, Bruce W.
    Battelino, Tadej
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 : S13 - S31
  • [24] Reimbursement for Continuous Glucose Monitoring
    Heinemann, Lutz
    DeVries, J. Hans
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : 48 - 52
  • [25] Continuous Glucose Monitoring in 2014
    Bode, Bruce W.
    Battelino, Tadej
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 : S12 - S20
  • [26] Continuous Glucose Monitoring in Gastroparesis
    Zeeshan Ramzan
    Frank Duffy
    Javier Gomez
    Robert S. Fisher
    Henry P. Parkman
    Digestive Diseases and Sciences, 2011, 56
  • [27] Continuous Glucose Monitoring in Gastroparesis
    Ramzan, Zeeshan
    Duffy, Frank
    Gomez, Javier
    Fisher, Robert S.
    Parkman, Henry P.
    DIGESTIVE DISEASES AND SCIENCES, 2011, 56 (09) : 2646 - 2655
  • [28] CONTINUOUS MONITORING OF BLOOD GLUCOSE
    ROSEVEAR, JW
    CLINICAL CHEMISTRY, 1971, 17 (07) : 628 - &
  • [29] Continuous Glucose Monitoring in Pregnancy
    Horgan, Rebecca
    Diab, Yara Hage
    Bartal, Michal Fishel
    Sibai, Baha M.
    Saade, George
    OBSTETRICS AND GYNECOLOGY, 2024, 143 (02): : 195 - 203
  • [30] Continuous glucose monitoring in pregnancy
    Novakovic, Ivana
    Todorovic, Jovana
    Dugalic, Stefan
    Macura, Maja
    Milincic, Milos
    Gojnic, Miroslava
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2024, 152 (3-4) : 214 - 217