Photonic Nanochains for Continuous Glucose Monitoring in Physiological Environment

被引:0
|
作者
Shi, Gongpu [1 ]
Si, Luying [1 ]
Cai, Jinyang [2 ]
Jiang, Hao [1 ]
Liu, Yun [1 ]
Luo, Wei [2 ]
Ma, Huiru [3 ]
Guan, Jianguo [1 ,4 ]
机构
[1] Wuhan Univ Technol, Int Sch Mat Sci & Engn, State Key Lab Adv Technol Mat Synth & Proc, Wuhan 430070, Peoples R China
[2] Wuhan Univ Technol, Sch Mat Sci & Engn, Wuhan 430070, Peoples R China
[3] Wuhan Univ Technol, Sch Chem Chem Engn & Life Sci, Wuhan 430070, Peoples R China
[4] Wuhan Inst Photochem & Technol, 7 North Bingang Rd, Wuhan 430083, Peoples R China
基金
中国国家自然科学基金;
关键词
glucose monitor; responsive photonic nanochains; colorimetric sensor; physiological environment; HYDROGEL; CRYSTAL; BEARING;
D O I
10.3390/nano14110964
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Diabetes is a common disease that seriously endangers human health. Continuous glucose monitoring (CGM) is important for the prevention and treatment of diabetes. Glucose-sensing photonic nanochains (PNCs) have the advantages of naked-eye colorimetric readouts, short response time and noninvasive detection of diabetes, showing immense potential in CGM systems. However, the developed PNCs cannot disperse in physiological environment at the pH of 7.4 because of their poor hydrophilicity. In this study, we report a new kind of PNCs that can continuously and reversibly detect the concentration of glucose (Cg) in physiological environment at the pH of 7.4. Polyacrylic acid (PAA) added to the preparation of PNCs forms hydrogen bonds with polyvinylpyrrolidone (PVP) in Fe3O4@PVP colloidal nanoparticles and the hydrophilic monomer N-2-hydroxyethyl acrylamide (HEAAm), which increases the content of PHEAAm in the polymer shell of prepared PNCs. Moreover, 4-(2-acrylamidoethylcarbamoyl)-3-fluorophenylboronic acid (AFPBA), with a relatively low pKa value, is used as the glucose-sensing monomer to further improve the hydrophilicity and glucose-sensing performances of PNCs. The obtained Fe3O4@(PVP-PAA)@poly(AFPBA-co-HEAAm) PNCs disperse in artificial serum and change color from yellow-green to red when Cg increases from 3.9 mM to 11.4 mM, showing application potential for straightforward CGM.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Continuous glucose monitoring using wearable non-enzymatic sensors in a physiological environment
    Abbasnia Tehrani M.
    Ahmadi S.H.
    Alimohammadi S.
    Sasanpour P.
    Batvani N.
    Kazemi S.H.
    Kiani M.A.
    Biosensors and Bioelectronics: X, 2024, 18
  • [2] Continuous Glucose Monitoring: Physiological and Technological Challenges
    Reach, Gerard
    Choleau, Carine
    CURRENT DIABETES REVIEWS, 2008, 4 (03) : 175 - 180
  • [3] Photonic hydrogel for continuous glucose monitoring using smartphone readout
    Ahmed, Israr
    Elsherif, Mohamed
    Ali, Murad
    Al Ghaferi, Amal
    Mohammad, Baker
    Butt, Haider
    MATERIALS & DESIGN, 2023, 231
  • [4] Continuous physiological monitoring
    Pavlidis, L
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 1084 - 1087
  • [5] Magnetically Responsive Photonic Nanochains
    Hu, Yongxing
    He, Le
    Yin, Yadong
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (16) : 3747 - 3750
  • [6] A Glucose Sensing Contact Lens: A Non-Invasive Technique for Continuous Physiological Glucose Monitoring
    Ramachandram Badugu
    Joseph R. Lakowicz
    Chris D. Geddes
    Journal of Fluorescence, 2003, 13 : 371 - 374
  • [7] A glucose sensing contact lens: A non-invasive technique for continuous physiological glucose monitoring
    Badugu, R
    Lakowicz, JR
    Geddes, CD
    JOURNAL OF FLUORESCENCE, 2003, 13 (05) : 371 - 374
  • [8] The Impact of Real Time Continuous Glucose Monitoring in the Classroom/School Environment
    Aye, Tandy
    Block, Jennifer M.
    Buckingham, Bruce A.
    Wilson, Darrell M.
    DIABETES, 2011, 60 : A248 - A248
  • [9] Continuous glucose monitoring
    Lewis, Dana M.
    Oser, Tamara K.
    Wheeler, Benjamin J.
    BMJ-BRITISH MEDICAL JOURNAL, 2023, 380
  • [10] Continuous glucose monitoring
    Harris, Stewart B.
    Bari, Basel
    Gilbert, Jeremy
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2024, 196 (09) : E325 - E326