Simplified Beam Hardening Correction for Ultrafast X-ray CT Imaging of Binary Granular Mixtures

被引:2
|
作者
Bieberle, Martina [1 ]
Papapetrou, Theodoros Nestor [1 ,2 ]
Lecrivain, Gregory [1 ]
Windisch, Dominic [2 ]
Bieberle, Andre [1 ]
Wagner, Michael [2 ]
Hampel, Uwe [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, Inst Fluid Dynam, Bautzner Landstr 400, D-01328 Dresden, Germany
[2] TUD Dresden Univ Technol, Inst Power Engn, Nothnitzer Str 69, D-01062 Dresden, Germany
关键词
beam hardening; computed tomography; image reconstruction; ultrafast measurement; granular media; particle mixing; rotating drum; SEGREGATION;
D O I
10.3390/s24102964
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ultrafast X-ray computed tomography is an advanced imaging technique for multiphase flows. It has been used with great success for studying gas-liquid as well as gas-solid flows. Here, we apply this technique to analyze density-driven particle segregation in a rotating drum as an exemplary use case for analyzing industrial particle mixing systems. As glass particles are used as the denser of two granular species to be mixed, beam hardening artefacts occur and hamper the data analysis. In the general case of a distribution of arbitrary materials, the inverse problem of image reconstruction with energy-dependent attenuation is often ill-posed. Consequently, commonly known beam hardening correction algorithms are often quite complex. In our case, however, the number of materials is limited. We therefore propose a correction algorithm simplified by taking advantage of the known material properties, and demonstrate its ability to improve image quality and subsequent analyses significantly.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] An experimental study on the influence of scatter and beam hardening in x-ray CT for dimensional metrology
    Lifton, J. J.
    Malcolm, A. A.
    McBride, J. W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (01)
  • [42] Quantitative X-ray diffraction and X-ray fluorescence analyses of mixtures – unified and simplified
    Chung, Frank H. (fhchung1@gmail.com), 1600, Wiley-Blackwell, 5 Abbey Road, Chester, CH1 2HU, United Kingdom (51):
  • [43] Quantitative X-ray diffraction and X-ray fluorescence analyses of mixtures - unified and simplified
    Chung, Frank H.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2018, 51 : 789 - 795
  • [44] Ultrafast x-ray imaging of fuel sprays
    Wang, Jin
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1535 - 1538
  • [45] Beam hardening correction method forturbine blades CT imaging
    Zhang Lei
    Fu Jian
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 4188 - 4191
  • [46] X-ray hardening correction for ICT in testing workpiece
    Peng Guang-han
    Cai Xin-hua
    Han Zhong
    Yang Xue-heng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (06) : 1426 - 1429
  • [47] X-ray hardening correction for ICT in testing workpiece
    College of Physics and Electronic Science, Hunan University of Arts and Science, Changde 415000, China
    不详
    不详
    Guang Pu Xue Yu Guang Pu Fen Xi, 2008, 6 (1426-1429):
  • [48] The effect of beam hardening on resolution in X-ray microtomography
    Van de Casteele, E
    Van Dyck, D
    Sijbers, J
    Raman, E
    MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3, 2004, 5370 : 2089 - 2096
  • [49] Beam-hardening in simulated X-ray tomography
    Ramakrishna, K.
    Muralidhar, K.
    Munshi, P.
    NDT & E INTERNATIONAL, 2006, 39 (06) : 449 - 457
  • [50] Cone beam x-ray CT will be superior to digital x-ray tomosynthesis in imaging the breast and delineating cancer
    Karellas, Andrew
    Lo, Joseph Y.
    Orton, Colin G.
    MEDICAL PHYSICS, 2008, 35 (02) : 409 - 411