X-ray hardening correction for ICT in testing workpiece

被引:0
|
作者
Peng Guang-han [1 ,2 ]
Cai Xin-hua [1 ]
Han Zhong [3 ]
Yang Xue-heng [3 ]
机构
[1] Hunan Univ Arts & Sci, Coll Phys & Elect Sci, Changde 415000, Peoples R China
[2] Chongqing Univ, Coll Automat, Chongqing 400030, Peoples R China
[3] Chongqing Univ, Coll Sci, Chongqing 400030, Peoples R China
关键词
X-ray; industrial computerized tomography; hardening correction; beam sum;
D O I
暂无
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Since energy spectrum of X-ray is polychromatic source in X-ray industrial computerized tomography, the variation of attenuation coefficient with energy leads to the lower energy of X-ray radiation being absorbed preferentially when X-ray is transmitting the materials. And the higher the energy of X-ray, the lower the attenuation coefficient of X-ray. With the increase in the X-ray transmission thickness, it becomes easier for the X-ray to transmit the matter. Thus, the phenomenon of energy spectrum hardening of X-ray takes place, resulting from the interaction between X-ray and the materials. This results in false images in the reconstruction of X-ray industrial computerized tomography. Therefore, hardening correction of energy spectrum of X-ray has to be done. In the present paper, not only is the hardening phenomenon of X-ray transmitting the materials analyzed, but also the relation between the X-ray beam sum and the transmission thickness of X-ray is discussed. And according to the Beer law and the characteristics of interaction when X-ray is transmitting material, and by getting the data of X-ray beam sum, the relation equation is fitted between the X-ray beam sum and X-ray transmission thickness. Then, the relation and the method of equivalence are carried out for X-ray beam sum being corrected. Finally, the equivalent and monochromatic attenuation coefficient fitted value for X-ray transmitting the material is reasoned out. The attenuation coefficient fitted value is used for product back-projection image reconstruction in X-ray industrial computerized tomography. Thus, the effect caused by X-ray beam hardening is wiped off effectively in X-ray industrial computerized tomography.
引用
收藏
页码:1426 / 1429
页数:4
相关论文
共 8 条
  • [1] BARBARA RK, 1990, MATER EVAL, V49, P1296
  • [2] FERREIRA DPR, 1998, NDT INT, V31, P17
  • [3] DETECT - Dual energy transmission estimation CT - for improved attenuation correction in SPECT and PET
    Guy, MJ
    Castellano-Smith, IA
    Flower, MA
    Flux, GD
    Ott, RJ
    Visvikis, D
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (03) : 1261 - 1267
  • [4] DETERMINATION OF MATERIAL FLAW SIZE BY INTENSITY EVALUATION OF POLYCHROMATIC X-RAY TRANSMISSION
    HANKE, R
    BOBEL, F
    [J]. NDT & E INTERNATIONAL, 1992, 25 (02) : 87 - 93
  • [5] Peng GH, 2005, SPECTROSC SPECT ANAL, V25, P1880
  • [6] Peng GH, 2007, SPECTROSC SPECT ANAL, V27, P1882
  • [7] Peng GH, 2007, SPECTROSC SPECT ANAL, V27, P823
  • [8] ZHANG LM, 1996, J CHINA U SCI TECHNO, V26, P510