Reliability and validity of the 6-minute pegboard and ring test for functional exercise capacity in patients with breast cancer

被引:0
|
作者
Oncu, Hacer [1 ,4 ]
Calik-Kutukcu, Ebru [1 ]
Yagli, Naciye Vardar [1 ]
Inal-Ince, Deniz [1 ]
Saglam, Melda [1 ]
Unal, Ferhat [2 ]
Aksoy, Sercan [3 ]
机构
[1] Hacettepe Univ, Fac Phys Therapy & Rehabil, Dept Cardioresp Physiotherapy & Rehabil, Ankara, Turkiye
[2] Middle East Tech Univ, Data Management Unit, Ankara, Turkiye
[3] Hacettepe Univ, Inst Oncol, Dept Med Oncol, Ankara, Turkiye
[4] Hacettepe Univ, Fac Phys Therapy & Rehabil, Dept Cardioresp Physiotherapy & Rehabil, TR-06100 Samanpazari, Ankara, Turkiye
关键词
Arm ergometry test; breast cancer; exercise tolerance test; upper extremity; LYMPHEDEMA; PAIN; SURVIVORS; DISSECTION; STRENGTH; SURGERY;
D O I
10.1080/09593985.2024.2353260
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Chronic pain, sensory disturbances, and lymphedema are frequent after breast cancer, leading to arm dysfunction. There is a need for objective performance-based clinical exercise tests for the upper extremity in patients with breast cancer. Objective: The aim of this study was to evaluate the validity and reliability of the 6-minute pegboard and ring test (6PBRT) in breast cancer survivors. Methods: Forty-eight women with breast cancer (mean age = 55.40 +/- 10.40 years) were included. All patients performed 6PBRT on the first day and one week later to investigate the test-retest reliability of the 6PBRT, and intraclass correlation coefficients (ICC) were calculated. The peak workload (W-peak) and oxygen consumption level (VO2peak) during the arm ergometer test were used as outcomes for the criterion validity of the 6PBRT. Results: The 6PBRT showed good test - retest reliability with an ICC1,2 value of 0.871 [95% confidence interval (CI) 0.769-0.928]. The first 6PBRT score was very strongly correlated with the second test score (r = 0.866, p < .001). The 6PBRT score was significantly correlated with VO2peak (r = 0.634, p < .001), and W-peak (r = 0.546, p < .001). While the 6PBRT score had less effect on VO2peak, the determination of VO2peak in the model was very good (R-2 = 0.832). Conclusion: The 6PBRT has good test-retest reliability and is a valid test in individuals with breast cancer. These findings suggest that 6PBRT is a practical, useful, valid and reliable assessment tool for determining functional arm exercise capacity in patients with breast cancer.
引用
收藏
页码:643 / 655
页数:13
相关论文
共 50 条
  • [31] The reliability and validity of a 6-minute walk test as a measure of physical endurance in older adults
    Rikli, RE
    Jones, CJ
    JOURNAL OF AGING AND PHYSICAL ACTIVITY, 1998, 6 (04) : 363 - 375
  • [32] Reliability, construct validity and determinants of 6-minute walk distance in patients with asthma
    Meys, Roy
    Janssen, Steffi
    Franssen, Frits
    Vaes, Anouk
    Stoffels, Anouk
    Van Hees, Hieronymus
    Van Den Borst, Bram
    Klijn, Peter
    Burtin, Chris
    Hul, Alex Van 'T
    Spruit, Martijn
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [33] Test-retest reliability, construct validity and determinants of 6-minute walk test performance in adult patients with asthma
    Meys, R.
    Janssen, S. M. J.
    Franssena, F. M. E.
    Vaesa, A. W.
    Stoffels, A. A. F.
    van Hees, H. W. H.
    van den Borstd, B.
    Klijn, P. H.
    Burtin, C.
    van 't Hul, A. J.
    Spruit, M. A.
    PULMONOLOGY, 2023, 29 (06): : 486 - 494
  • [34] RELIABILITY AND VALIDITY OF THE 6-MINUTE WALK TEST AS AN OUTCOME MEASURE IN OCULOPHARYNGEAL MUSCULAR DYSTROPHY
    Fernandez, M.
    Youssof, S.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (01) : 344 - 345
  • [35] Reliability of the 6-minute walk test in patients referred for pulmonary rehabilitation
    van der Schoot, H. J. M.
    van Ranst, D.
    Otten, H. J.
    Stoop, W. A.
    van de Port, I. G.
    Meijer, J. W.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [36] Evaluation exercise tolerance in COPD patients:: The 6-minute walking test
    Rabinovich, RA
    Vilaró, J
    Roca, J
    ARCHIVOS DE BRONCONEUMOLOGIA, 2004, 40 (02): : 80 - 85
  • [37] Application of a new parameter in the 6-minute walk test for manifold analysis of exercise capacity in patients with COPD
    Ijiri, Naoki
    Kanazawa, Hiroshi
    Yoshikawa, Takahiro
    Hirata, Kazuto
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2014, 9 : 1235 - 1240
  • [38] The 6-minute pegboard and ring test is correlated with upper extremity activity of daily living in chronic obstructive pulmonary disease
    Takeda, Kenichi
    Kawasaki, Yuji
    Yoshida, Kazumasa
    Nishida, Yoji
    Harada, Tomoya
    Yamaguchi, Kosuke
    Ito, Shizuka
    Hashimoto, Kiyoshi
    Matsumoto, Shingo
    Yamasaki, Akira
    Igishi, Tadashi
    Shimizu, Eiji
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2013, 8 : 347 - 351
  • [39] 6-minute walk work for assessment of functional capacity in patients with COPD
    Carter, R
    Holiday, DB
    Nwasuruba, C
    Stocks, J
    Grothues, C
    Tiep, B
    CHEST, 2003, 123 (05) : 1408 - 1415
  • [40] Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
    Elkjaer, Amanda Lynggaard
    Naeser, Esben Uggerby
    Aaen, Katja Thorup
    Hovgaard, Henrik Lynge
    Juhl-Olsen, Peter
    Bendstrup, Elisabeth
    Sondergaard, Klaus
    RHEUMATOLOGY INTERNATIONAL, 2024, 44 (04) : 611 - 620