Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis

被引:0
|
作者
Elkjaer, Amanda Lynggaard [1 ]
Naeser, Esben Uggerby [1 ,3 ]
Aaen, Katja Thorup [1 ]
Hovgaard, Henrik Lynge [2 ]
Juhl-Olsen, Peter [2 ,3 ]
Bendstrup, Elisabeth [3 ,4 ]
Sondergaard, Klaus [1 ,3 ]
机构
[1] Aarhus Univ Hosp, Dept Rheumatol, Palle Juul Jensens Blvd 59, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, Dept Anaesthesiol & Intens Care, Palle Juul Jensens Blvd 99, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Dept Clin Med, Palle Juul Jensens Blvd 91, DK-8200 Aarhus N, Denmark
[4] Aarhus Univ Hosp, Dept Resp Dis & Allergy, Palle Juul Jensens,Blvd 99, DK-8200 Aarhus N, Denmark
关键词
Reproducibility of Results; Oximetry; Walk Test; Scleroderma; Systemic; EULAR SCLERODERMA TRIALS; PULSE OXIMETRY; GUIDELINES; STATEMENT;
D O I
10.1007/s00296-024-05532-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripheral oxygen saturation (SpO2) using the fingers may have important limitations due to Raynaud's phenomenon and sclerodactyly in patients with systemic sclerosis (SSc). Sensors located at more central body positions may be more accurate as these as less prone to Raynaud attacks. To determine the validity and reliability of the SpO2 measured at the finger, forehead, and earlobe during the 6-Minute Walk Test (6MWT). Eighty two patients with SSc had an arterial line placed while performing the 6MWT. Peripheral oxygen saturation was simultaneously measured by finger, forehead, and earlobe sensors and compared to the arterial oxygen saturation (SaO2) measured before and after the 6MWT. 40 patients repeated the 6MWT one week later to determine re-test reliability. We used Bland-Altman plots to display the agreement between SpO2 and SaO2. The intraclass correlation coefficient for repeated measurement of minimum SpO2 was calculated. The mean difference between SpO2 and SaO2 after the 6MWT was - 3% (SD: +/- 5), 0% (SD: +/- 2), and 1% (SD: +/- 2) for the finger, forehead, and earlobe, respectively. The minimum SpO2 measured at the finger demonstrated the poorest re-test reliability: The ICC (95% CI) showed good agreement using the ear and forehead probe (ICCear = 0.89 [95% CI 0.80; 0.94]; ICCforehead = 0.77 [95% CI 0.60; 0.87]), while a modest reliability was found using the finger probe (ICCfinger = 0.65 95% CI [0.43; 0.80]). SpO2 should be measured using either the earlobe or forehead during the 6MWT in patients with SSc. Clinical Trials.Gov (NCT04650659).
引用
收藏
页码:611 / 620
页数:10
相关论文
共 50 条
  • [1] VALIDITY AND RELIABILITY OF MEASUREMENT OF PERIPHERAL OXYGEN SATURATION DURING THE 6-MINUTE WALK TEST IN PATIENTS WITH SYSTEMIC SCLEROSIS
    Cano Garcia, L.
    Redondo, R.
    Al Mashhadani, N.
    Ordonez Canizares, M. D. C.
    Mena-Vazquez, N.
    Manrique Arija, S.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 1623 - 1624
  • [2] Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
    Riis, A. Lynggaard
    Naeser, E.
    Aaen, K. Thorup
    Hovgaard, H. Lynge
    Juhl-Olsen, P.
    Bendstrup, E.
    Sondergaard, K.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2023, 52 : 16 - 18
  • [3] Validity and reliability of measurement of peripheral oxygen saturation during the 6-Minute Walk Test in patients with systemic sclerosis
    Amanda Lynggaard Elkjær
    Esben Uggerby Næser
    Katja Thorup Aaen
    Henrik Lynge Hovgaard
    Peter Juhl-Olsen
    Elisabeth Bendstrup
    Klaus Søndergaard
    Rheumatology International, 2024, 44 : 611 - 620
  • [4] Reliability and Validity of the 6-Minute Walk Test in Hypophosphatasia
    Phillips, Dawn
    Tomazos, Ioannis C.
    Moseley, Scott
    L'Italien, Gil
    Gomes da Silva, Hugo
    Lerma Lara, Sergio
    JBMR PLUS, 2019, 3 (06)
  • [5] Using a treadmill for the 6-minute walk test - Reliability and validity
    Laskin, James J.
    Bundy, Sadie
    Marron, Hanna
    Moore, Holly
    Swanson, Melissa
    Blair, Molly
    Humphrey, Reed
    JOURNAL OF CARDIOPULMONARY REHABILITATION AND PREVENTION, 2007, 27 (06) : 407 - 410
  • [6] Reproducibility and Utility of the 6-minute Walk Test in Systemic Sclerosis
    Pugnet, Gregory
    Marjanovic, Zora
    Deligny, Christophe
    Boussardon, Karine
    Benzidia, Ilham
    Puyade, Mathieu
    Lansiaux, Pauline
    Vandecasteele, Els
    Smith, Vanessa
    Farge, Dominique
    JOURNAL OF RHEUMATOLOGY, 2018, 45 (09) : 1273 - 1280
  • [7] Reliability Of 6-Minute Walk Distance, Oxyhaemoglobin Saturation And Heart Rate Measured During The 6-Minute Walk Test In Idiopathic Pulmonary Fibrosis
    Holland, A. E.
    Hill, C. J.
    Dowman, L.
    Glaspole, I.
    Goh, N.
    Westall, G.
    Symons, K.
    McDonald, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2013, 187
  • [8] Validity and reliability of the 6-minute walk test over a distance of 6 meters in people with multiple sclerosis
    Ferchichi-Barbey, Sylvie
    Guex, Kenny
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (3_SUPPL) : 14 - 14
  • [9] Prognostic Value of Walk Distance, Work, Oxygen Saturation, and Dyspnea During 6-Minute Walk Test in COPD Patients
    Golpe, Rafael
    Perez-de-Llano, Luis A.
    Mendez-Marote, Lidia
    Veres-Racamonde, Alejandro
    RESPIRATORY CARE, 2013, 58 (08) : 1329 - 1334
  • [10] Factors relating to impaired stroke volume during the 6-minute walk test in patients with systemic sclerosis
    Someya, F.
    Mugii, N.
    Oohata, S.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2016, 34 (05) : S152 - S156