Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode

被引:2
|
作者
Bhimaraya, Kanthappa [1 ]
Manjunatha, J. G. [1 ]
Almutairi, Tahani Mazyad [2 ]
Ataollahi, Narges [3 ]
机构
[1] Mangalore Univ, FMKMC Coll, Constituent Coll, Dept Chem, Madikeri, India
[2] King Saud Univ, Coll Sci, Dept Chem, Riyadh, Saudi Arabia
[3] Univ Trento, Dept Civil Environm & Mech Engn, Trento, Italy
关键词
Hydroquinone; catechol; L-leucine; graphite powder; graphene powder; electrochemical analyser; GLASSY-CARBON ELECTRODE; DIHYDROXYBENZENE ISOMERS; ELECTROCHEMICAL DETERMINATION; OXIDE; NANOPARTICLES; PHENOL; WATER; FILM; ADSORPTION; KINETICS;
D O I
10.1080/03067319.2024.2404534
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An innovative electrochemical redox response of hydroquinone (HQN) and catechol (CCL) was analysed using a bare graphite and graphene composite paste electrode (BGGCPE) and polymerised L-leucine modified graphite and graphene composite paste electrode (LCN-MGGCPE) was successfully developed in 0.2 M phosphate buffer solution (PBS) with pH 6.0 at a 0.1 V/s scan rate. Fabricated electrode using simple and cost-effective method, the polymerised LCN-MGGCPE surface shows more electrochemical activity, sensitivity and selectivity towards the determination for HQN and CCL. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), Differential pulse voltammetry (DPV), and electrochemical impudence spectroscopy (EIS) were utilised as analytical techniques while LCN-MGGCPE and BGGCPE surface characterisation were studied using a scanning electron microscopy (SEM) technique. LCN-MGGCPE exhibited superior electrochemical activity compared to BGGCPE towards the oxidation responses of both HQN and CCL. Additionally, the effect of pH studies, scan rate change for HQN, and concentration change of analyte molecule were examined, with the 0.025 to 0.500 V/s scan rate varied and revealing an adsorption-controlled process. The concentration changes of CVs methods ranged from 0.2 to 320 mu M, DPVs ranged from 0.2 to 1100 mu M and LSVs ranged from 0.2 to 850 mu M, the calculated a limit of detection (LOD) of CV, DPV, and LSV, is 0.020 mu M, 0.026 mu M, and 0.011 mu M and a limit of quantification (LOQ) of 0.068 mu M, 0.088 mu M, and 0.035 mu M. The electrochemically developed LCN-MGGCPE shows good reproducibility, repeatability, stability, sensitivity and simultaneous analysis of analyte molecules were studied. This study presents a promising pathway for the growth of effective sensors for the determination of HQN in medicinal and water sample applications.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] Simultaneous determination of catechol and hydroquinone based on poly(sulfosalicylic acid)/functionalized graphene modified electrode
    Cong Li
    Weilu Liu
    Yue Gu
    Shuming Hao
    Xiaoyi Yan
    Zhiquan Zhang
    Ming Yang
    Journal of Applied Electrochemistry, 2014, 44 : 1059 - 1067
  • [42] Electrocatalytic Oxidation of NADH on Functionalized Graphene Modified Graphite Electrode
    Kumar, Simson Prasanna
    Manjunatha, Revanasiddappa
    Nethravathi, C.
    Suresh, Gurukar Shivappa
    Rajamathi, Michael
    Venkatesha, Thimmappa Venkatarangaiah
    ELECTROANALYSIS, 2011, 23 (04) : 842 - 849
  • [43] Electrochemical Investigation of Catechol and Hydroquinone at Poly(o-Phenylenediamine) Modified Carbon Paste Electrode: A Voltammetric Study
    Chetankumar, K.
    Swamy, B. E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2019, 11 (12): : 1638 - 1650
  • [44] Simultaneous determination of hydroquinone and catechol at PASA/MWNTs composite film modified glassy carbon electrode
    Zhao, Dong-Ming
    Zhang, Xiu-Hua
    Feng, Li-Jun
    Jia, Li
    Wang, Sheng-Fu
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 74 (01) : 317 - 321
  • [45] Pre-Treated Cadmium Oxide Modified Carbon Paste Electrode Sensor for Catechol and Hydroquinone in the Presence of Resorcinol
    Manjunatha, L. S.
    Swamy, B. E. Kumara
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2023, 15 (07): : 531 - 544
  • [46] Simultaneous electrochemical detection of hydroquinone and catechol using MWCNT-COOH/CTF-1 composite modified electrode
    Yang, Meng
    Guo, Hao
    Sun, Lei
    Wu, Ning
    Wang, Mingyue
    Yang, Fan
    Zhang, Tingting
    Zhang, Junye
    Pan, Zhilan
    Yang, Wu
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2021, 625
  • [47] Simultaneous Determination of Catechol and Hydroquinone at a Carbon Nanotubes Modified Electrode
    Yang Shao-Ming
    Wei Zhi-Peng
    Hu Guang-Hui
    Jiang Dan
    Huang Ai-Hua
    Zheng Long-Zhen
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2010, 31 (02): : 264 - 268
  • [48] Determination of hydroquinone and catechol at a poly(Arginine acid) modified electrode
    Yue Hua, A.
    Huang, Jin Zhan
    Song, Zong Rong
    Zhang, Ying
    Song, Li
    Sensors and Transducers, 2014, 175 (07): : 1 - 5
  • [49] Amperometric sensing of hydroquinone using a glassy carbon electrode modified with a composite consisting of graphene and molybdenum disulfide
    Huayu Huang
    Jiangyi Zhang
    Meimei Cheng
    Kunping Liu
    Xingyu Wang
    Microchimica Acta, 2017, 184 : 4803 - 4808
  • [50] Amperometric sensing of hydroquinone using a glassy carbon electrode modified with a composite consisting of graphene and molybdenum disulfide
    Huang, Huayu
    Zhang, Jiangyi
    Cheng, Meimei
    Liu, Kunping
    Wang, Xingyu
    MICROCHIMICA ACTA, 2017, 184 (12) : 4803 - 4808