Enhancing of hydroquinone and catechol oxidation using a graphite and graphene composite polymer modified paste electrode

被引:2
|
作者
Bhimaraya, Kanthappa [1 ]
Manjunatha, J. G. [1 ]
Almutairi, Tahani Mazyad [2 ]
Ataollahi, Narges [3 ]
机构
[1] Mangalore Univ, FMKMC Coll, Constituent Coll, Dept Chem, Madikeri, India
[2] King Saud Univ, Coll Sci, Dept Chem, Riyadh, Saudi Arabia
[3] Univ Trento, Dept Civil Environm & Mech Engn, Trento, Italy
关键词
Hydroquinone; catechol; L-leucine; graphite powder; graphene powder; electrochemical analyser; GLASSY-CARBON ELECTRODE; DIHYDROXYBENZENE ISOMERS; ELECTROCHEMICAL DETERMINATION; OXIDE; NANOPARTICLES; PHENOL; WATER; FILM; ADSORPTION; KINETICS;
D O I
10.1080/03067319.2024.2404534
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An innovative electrochemical redox response of hydroquinone (HQN) and catechol (CCL) was analysed using a bare graphite and graphene composite paste electrode (BGGCPE) and polymerised L-leucine modified graphite and graphene composite paste electrode (LCN-MGGCPE) was successfully developed in 0.2 M phosphate buffer solution (PBS) with pH 6.0 at a 0.1 V/s scan rate. Fabricated electrode using simple and cost-effective method, the polymerised LCN-MGGCPE surface shows more electrochemical activity, sensitivity and selectivity towards the determination for HQN and CCL. Cyclic voltammetry (CV), linear sweep voltammetry (LSV), Differential pulse voltammetry (DPV), and electrochemical impudence spectroscopy (EIS) were utilised as analytical techniques while LCN-MGGCPE and BGGCPE surface characterisation were studied using a scanning electron microscopy (SEM) technique. LCN-MGGCPE exhibited superior electrochemical activity compared to BGGCPE towards the oxidation responses of both HQN and CCL. Additionally, the effect of pH studies, scan rate change for HQN, and concentration change of analyte molecule were examined, with the 0.025 to 0.500 V/s scan rate varied and revealing an adsorption-controlled process. The concentration changes of CVs methods ranged from 0.2 to 320 mu M, DPVs ranged from 0.2 to 1100 mu M and LSVs ranged from 0.2 to 850 mu M, the calculated a limit of detection (LOD) of CV, DPV, and LSV, is 0.020 mu M, 0.026 mu M, and 0.011 mu M and a limit of quantification (LOQ) of 0.068 mu M, 0.088 mu M, and 0.035 mu M. The electrochemically developed LCN-MGGCPE shows good reproducibility, repeatability, stability, sensitivity and simultaneous analysis of analyte molecules were studied. This study presents a promising pathway for the growth of effective sensors for the determination of HQN in medicinal and water sample applications.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] MIL-101 (Fe) modified carbon paste electrode for the efficient simultaneous detection of hydroquinone and catechol
    Zhu, Mengting
    Xu, Ruli
    Wang, Xueyang
    Liu, Jie
    Zhang, Qianli
    Wei, Jie
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2021, 16 (12):
  • [32] NiO nanoparticles modified carbon paste electrode for the voltammetric simultaneous detection of catechol and hydroquinone as environmental pollutants
    Achache, Mohamed
    Ben Seddik, Nordin
    Bouchta, Dounia
    Draoui, Khalid
    Choukairi, Mohamed
    MICROCHEMICAL JOURNAL, 2025, 208
  • [33] A Novel Electrochemical Sensor for Simultaneous Determination of Hydroquinone, Catechol, and Resorcinol using a Carbon Paste Electrode modified by Zn-MOF, Nitrogen-doped Graphite, and AuNPs
    Mashhadizadeh, Mohammad Hossain
    Kalantarian, S. Marzieh
    Azhdeh, Afsaneh
    ELECTROANALYSIS, 2021, 33 (01) : 160 - 169
  • [34] Simultaneous electroanalysis of hydroquinone and catechol at poly(brilliant blue) modified carbon paste electrode: A voltammetric study
    Ganesh, P. S.
    Swamy, B. E. Kumara
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 756 : 193 - 200
  • [35] Simultaneous detection of catechol and hydroquinone on Ni-Al layered double hydroxide/reduced graphene composite electrode modified with laccase
    Liu, Yuge
    Li, Zhiguo
    Jia, Yongmei
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2025,
  • [36] Electrocatalytic oxidation and determination of ascorbic acid on polymer hydroquinone modified electrode
    Chen Xianguang
    Ren, Wang
    Zhao Guofang
    Zou Xiaoyong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (08) : 1063 - 1067
  • [37] Simultaneous electrochemical detection of hydroquinone and catechol using a carbon nanotube paste electrode modified with electrochemically polymerized L-alanine
    Manju, Manoj Koorgalli
    Manjunatha, Jamballi G.
    Bhimaraya, Kanathappa
    Aldossari, Samar A.
    Mohammad, Saikh
    Sillanpaa, Mika
    CHEMICAL PAPERS, 2024, 78 (14) : 8019 - 8030
  • [38] Simultaneous determination of catechol and hydroquinone using electrospun carbon nanofibers modified electrode
    Guo, Qiaohui
    Huang, Jianshe
    Chen, Puqing
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 163 (01) : 179 - 185
  • [39] Simultaneous determination of catechol and hydroquinone based on poly(sulfosalicylic acid)/functionalized graphene modified electrode
    Li, Cong
    Liu, Weilu
    Gu, Yue
    Hao, Shuming
    Yan, Xiaoyi
    Zhang, Zhiquan
    Yang, Ming
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (09) : 1059 - 1067
  • [40] Highly stable pyridinic nitrogen doped graphene modified electrode in simultaneous determination of hydroquinone and catechol
    Guo, Hui-Lin
    Peng, San
    Xu, Jian-Hua
    Zhao, Yi-Qing
    Kang, Xiaofeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 623 - 629