Hybrid Active and Passive Cable Contour Shielding of Magnetic Fields of Double-Circuit Overhead Power Lines

被引:0
|
作者
Kuznetsov, B., I [1 ]
Kutsenko, A. S. [2 ]
Nikitina, T. B. [3 ]
Bovdui, I., V [1 ]
Chunikhin, K., V [1 ]
Voloshko, O. V. [1 ]
机构
[1] Natl Acad Sci Ukraine, Anatolii Pidhornyi Inst, Mech Engn Problems, Kharkiv, Ukraine
[2] Natl Tech Univ KhPI, Kharkiv, Ukraine
[3] Ukrainian Engn Pedag Acad, Educ Sci profess pedag Inst, Kharkiv, Ukraine
来源
关键词
two-circuit overhead power lines; magnetic field; hybrid shielding; theoretical and experimental studies; OBJECTS;
D O I
10.52254/1857-0070.2024.2-62.02
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of the work is to design a hybrid screen designed to reduce the level of the magnetic field generated by double -circuit overhead power lines, to increase the efficiency of shielding the original magnetic field in residential buildings, to the level of sanitary standards and to reduce the sensitivity of the system to changes in system parameters. To achieve this goal, the structure of a hybrid screen was determined, consisting of a double contour active and a cable contour passive part. The developed hybrid screen is characterized by increased efficiency in reducing the magnetic field of industrial frequency. Designing a hybrid screen comes down to solving a minimax vector optimization problem, in which the vector objective function is calculated based on solution to Maxwell's equations in a quasi -stationary approximation using the COMSOL Multiphysics software package. The solution to the minimax vector optimization problem is calculated based on multiparticle swarm optimization algorithms from Pareto-optimal solutions taking into account binary preference relations. During the design of the hybrid screen, the coordinates of the spatial location of the two compensation windings, as well as the magnitude of the currents and its phases in the windings of the active screen, were calculated. The important results are theoretical and experimental studies on the effectiveness of the designed hybrid magnetic field shield generated by double -circuit overhead power lines. The significance of the results obtained lies in the fact that practical recommendations are given for a reasonable choice of the spatial arrangement of two shielding windings of a robust system of hybrid shielding of the magnetic field generated by double -circuit overhead power lines.
引用
收藏
页码:14 / 27
页数:14
相关论文
共 50 条
  • [41] Phasing Relevance on Magnetic Fields Generated by Overhead High Voltage Power Lines
    Alistar, Bogdan Dumitru
    Costin, George Daniel
    Neagu, Constantin Dan
    Bordeianu, Dragos Florin
    2019 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND ENERGY SYSTEMS (SIELMEN), 2019,
  • [42] The methods of reducing of the magnetic fields of overhead power lines outside security zones
    Pelevin, D.Ye., 1600, Institute of Electrodynamics, National Academy of Sciences of Ukraine (2014):
  • [43] Upon the Contribution of Image Currents on the Magnetic Fields Generated by Overhead Power Lines
    Salceanu, Alexandra
    Paulet, Marius
    Alistar, Bogdan Dumitru
    Asiminicesei, Oana
    2019 INTERNATIONAL CONFERENCE ON ELECTROMECHANICAL AND ENERGY SYSTEMS (SIELMEN), 2019,
  • [44] Improved electrogeometric model for shielding failure evaluation of double-circuit UHVAC transmission lines based on leader propagation simulations
    Ma, Ziwei
    Jasni, Jasronita
    Kadir, Mohd Zainal Abidin Ab
    Azis, Norhafiz
    Ma, Yanhua
    ELECTRIC POWER SYSTEMS RESEARCH, 2025, 239
  • [45] Protection Challenges for North America's First Combined Cable/Overhead Double-Circuit 500 kV Transmission Line With Mutual Coupling
    Bucco, Denis
    Sanden, Curtis
    Torres, Arturo
    Wong, Edward
    Bell, Jordan
    Fischer, Normann
    Thompson, John
    2017 70TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2017,
  • [46] Elliptically Polarized Magnetic Field of Electric Power Lines and Mitigation by Passive Shielding
    Liang, Zhenguang
    Li, Xiaotong
    Gu, Xue
    Jiang, Yuze
    2015 7TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS (CEEM), 2015, : 53 - 56
  • [47] Estimation of shielding failure number of different configurations of double-circuit transmission lines using leader progression analysis model
    M. Yahyaabadi
    B. Vahidi
    M. R. Bank Tavakoli
    Electrical Engineering, 2010, 92 : 79 - 85
  • [48] The Effectiveness of Compensated Passive Loops for Mitigating Underground Power Cable Magnetic Fields
    del Pino Lopez, Juan Carlos
    Cruz Romero, Pedro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 674 - 683
  • [49] THE INFLUENCE OF CONDUCTIVE PASSIVE PARTS ON THE MAGNETIC FLUX DENSITY PRODUCED BY OVERHEAD POWER LINES
    Vujevic, Slavko
    Modric, Tonci
    FACTA UNIVERSITATIS-SERIES ELECTRONICS AND ENERGETICS, 2019, 32 (04) : 555 - 569
  • [50] Shielding techniques of the low-frequency magnetic field from cable power lines
    D'Amore, M
    Menghi, E
    Sarto, MS
    2003 IEEE SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, SYMPOSIUM RECORD, VOLS 1 AND 2, 2003, : 203 - 208