Hybrid Active and Passive Cable Contour Shielding of Magnetic Fields of Double-Circuit Overhead Power Lines

被引:0
|
作者
Kuznetsov, B., I [1 ]
Kutsenko, A. S. [2 ]
Nikitina, T. B. [3 ]
Bovdui, I., V [1 ]
Chunikhin, K., V [1 ]
Voloshko, O. V. [1 ]
机构
[1] Natl Acad Sci Ukraine, Anatolii Pidhornyi Inst, Mech Engn Problems, Kharkiv, Ukraine
[2] Natl Tech Univ KhPI, Kharkiv, Ukraine
[3] Ukrainian Engn Pedag Acad, Educ Sci profess pedag Inst, Kharkiv, Ukraine
来源
关键词
two-circuit overhead power lines; magnetic field; hybrid shielding; theoretical and experimental studies; OBJECTS;
D O I
10.52254/1857-0070.2024.2-62.02
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of the work is to design a hybrid screen designed to reduce the level of the magnetic field generated by double -circuit overhead power lines, to increase the efficiency of shielding the original magnetic field in residential buildings, to the level of sanitary standards and to reduce the sensitivity of the system to changes in system parameters. To achieve this goal, the structure of a hybrid screen was determined, consisting of a double contour active and a cable contour passive part. The developed hybrid screen is characterized by increased efficiency in reducing the magnetic field of industrial frequency. Designing a hybrid screen comes down to solving a minimax vector optimization problem, in which the vector objective function is calculated based on solution to Maxwell's equations in a quasi -stationary approximation using the COMSOL Multiphysics software package. The solution to the minimax vector optimization problem is calculated based on multiparticle swarm optimization algorithms from Pareto-optimal solutions taking into account binary preference relations. During the design of the hybrid screen, the coordinates of the spatial location of the two compensation windings, as well as the magnitude of the currents and its phases in the windings of the active screen, were calculated. The important results are theoretical and experimental studies on the effectiveness of the designed hybrid magnetic field shield generated by double -circuit overhead power lines. The significance of the results obtained lies in the fact that practical recommendations are given for a reasonable choice of the spatial arrangement of two shielding windings of a robust system of hybrid shielding of the magnetic field generated by double -circuit overhead power lines.
引用
收藏
页码:14 / 27
页数:14
相关论文
共 50 条
  • [31] Optimization-based Fault Location on Double-Circuit Transmission Lines of Power Systems
    Huynh, Duy C.
    Truong, Thanh H.
    Dunnigan, Matthew W.
    2021 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, COMMUNICATION, COMPUTER TECHNOLOGIES AND OPTIMIZATION TECHNIQUES (ICEECCOT), 2021, : 746 - 751
  • [32] EFFICIENT POWER TRANSMISSION OVER SHORT DISTANCES USING CONTROLLED DOUBLE-CIRCUIT LINES
    HAMED, M
    PAPADOPOULOS, DP
    ELECTRIC POWER SYSTEMS RESEARCH, 1986, 11 (02) : 161 - 165
  • [33] Spatial Magnetic Field Polarization below Balanced Double-Circuit Linear Configured Power Lines for Six Phase Arrangements
    Ponnle, Akinlolu
    Adedeji, Kazeem
    Abe, Bolanle
    Jimoh, Adisa
    2015 INTL AEGEAN CONFERENCE ON ELECTRICAL MACHINES & POWER ELECTRONICS (ACEMP), 2015 INTL CONFERENCE ON OPTIMIZATION OF ELECTRICAL & ELECTRONIC EQUIPMENT (OPTIM) & 2015 INTL SYMPOSIUM ON ADVANCED ELECTROMECHANICAL MOTION SYSTEMS (ELECTROMOTION), 2015, : 163 - 169
  • [34] The role played by current phase shift on magnetic field established by AC double-circuit overhead transmission lines - Part 1: Static analysis
    Mazzanti, G
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 939 - 948
  • [35] Method of adjustment of three circuit system of active shielding of magnetic field in multi-storey buildings from overhead power lines with wires triangular arrangement
    Kuznetsov, B., I
    Nikitina, T. B.
    Bovdui, I., V
    Voloshko, O. V.
    Kolomiets, V. V.
    Kobilyanskiy, B. B.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2022, (01) : 21 - 28
  • [36] Lightning surges in hybrid cable-overhead lines: Part I—voltage estimation for shielding failure
    F. Faria da Silva
    Kasper Pedersen
    Electrical Engineering, 2022, 104 : 3281 - 3294
  • [37] Choice of parameters for passive shielding of power-frequency magnetic fields
    Salinas E.
    Rezinkina M.
    The Environmentalist, 2009, 29 (2): : 135 - 140
  • [38] DOUBLE-CIRCUIT RESONANT ELECTRIC POWER AMPLIFIER FOR MAGNETIC-PULSE PROCESSING OF METALS
    Batygin, Yu.V.
    Shinderuk, S.O.
    Chaplygin, E.O.
    Fendrikov, D.V.
    Technical Electrodynamics, 2022, 2022 (03): : 29 - 36
  • [39] Estimation of shielding failure number of different configurations of double-circuit transmission lines using leader progression analysis model
    Yahyaabadi, M.
    Vahidi, B.
    Tavakoli, M. R. Bank
    ELECTRICAL ENGINEERING, 2010, 92 (02) : 79 - 85
  • [40] Lightning surges in hybrid cable-overhead lines: Part I-voltage estimation for shielding failure
    da Silva, F. Faria
    Pedersen, Kasper
    ELECTRICAL ENGINEERING, 2022, 104 (05) : 3281 - 3294