Hybrid Active and Passive Cable Contour Shielding of Magnetic Fields of Double-Circuit Overhead Power Lines

被引:0
|
作者
Kuznetsov, B., I [1 ]
Kutsenko, A. S. [2 ]
Nikitina, T. B. [3 ]
Bovdui, I., V [1 ]
Chunikhin, K., V [1 ]
Voloshko, O. V. [1 ]
机构
[1] Natl Acad Sci Ukraine, Anatolii Pidhornyi Inst, Mech Engn Problems, Kharkiv, Ukraine
[2] Natl Tech Univ KhPI, Kharkiv, Ukraine
[3] Ukrainian Engn Pedag Acad, Educ Sci profess pedag Inst, Kharkiv, Ukraine
来源
关键词
two-circuit overhead power lines; magnetic field; hybrid shielding; theoretical and experimental studies; OBJECTS;
D O I
10.52254/1857-0070.2024.2-62.02
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The purpose of the work is to design a hybrid screen designed to reduce the level of the magnetic field generated by double -circuit overhead power lines, to increase the efficiency of shielding the original magnetic field in residential buildings, to the level of sanitary standards and to reduce the sensitivity of the system to changes in system parameters. To achieve this goal, the structure of a hybrid screen was determined, consisting of a double contour active and a cable contour passive part. The developed hybrid screen is characterized by increased efficiency in reducing the magnetic field of industrial frequency. Designing a hybrid screen comes down to solving a minimax vector optimization problem, in which the vector objective function is calculated based on solution to Maxwell's equations in a quasi -stationary approximation using the COMSOL Multiphysics software package. The solution to the minimax vector optimization problem is calculated based on multiparticle swarm optimization algorithms from Pareto-optimal solutions taking into account binary preference relations. During the design of the hybrid screen, the coordinates of the spatial location of the two compensation windings, as well as the magnitude of the currents and its phases in the windings of the active screen, were calculated. The important results are theoretical and experimental studies on the effectiveness of the designed hybrid magnetic field shield generated by double -circuit overhead power lines. The significance of the results obtained lies in the fact that practical recommendations are given for a reasonable choice of the spatial arrangement of two shielding windings of a robust system of hybrid shielding of the magnetic field generated by double -circuit overhead power lines.
引用
收藏
页码:14 / 27
页数:14
相关论文
共 50 条
  • [1] The method for design of electromagnetic hybrid active-passive shielding by overhead power lines magnetic field
    Kuznetsov, B. I.
    Nikitina, T. B.
    Bovdui, I. V.
    Chunikhin, K. V.
    Kolomiets, V. V.
    Kobylianskyi, B. B.
    ELECTRICAL ENGINEERING & ELECTROMECHANICS, 2024, (04) : 22 - 30
  • [2] Assessment of Lightning Shielding Performance of Double-Circuit UHV Overhead Transmission Lines
    He, Hengxin
    He, Junjia
    Xie, ShiJun
    Yao, Shuai
    Zhang, Dandan
    Dong, Manling
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [3] Hybrid Active-Passive Shielding of Magnetic Field of Overhead Power Lines with Triangular Phase Conductors Arrangements
    Kuznetsov, B. I.
    Kutsenko, A. S.
    Nikitina, T. B.
    Bovdui, I. V.
    Chunikhin, K. V.
    Dobrodeyev, P. N.
    PROBLEMELE ENERGETICII REGIONALE, 2023, (03): : 1 - 16
  • [4] Procedure for Verifying Population Exposure Limits to the Magnetic Field from Double-Circuit Overhead Power Lines
    Landini, Marco
    Mazzanti, Giovanni
    Mandrioli, Riccardo
    ELECTRICITY, 2021, 2 (03): : 342 - 358
  • [5] Current phase-shift effects in the calculation of magnetic fields generated by double-circuit overhead transmission lines
    Mazzanti, G
    2004 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1 AND 2, 2004, : 413 - 418
  • [6] Transmission Efficiency Optimization for the operation of double-circuit Overhead Lines
    Papazoglou, Thales M.
    ELEKTROTEHNISKI VESTNIK-ELECTROCHEMICAL REVIEW, 2011, 78 (03): : 102 - 105
  • [7] Magnetic field generated by double-circuit twisted three-phase cable lines
    Mazzanti G.
    Landini M.
    Kandia E.
    Bernabei A.
    Cavallina M.
    Landini, Marco (m.landini@unibo.it), 1600, Electromagnetics Academy (73): : 115 - 126
  • [8] Reducing the Magnetic Field Level of Single-Circuit Overhead Power Lines in Multi-Storey Buildings by Means of Active and Passive Shielding
    Kuznetsov, B. I.
    Kutsenko, A. S.
    Nikitina, T. B.
    Bovdui, I. V.
    Chunikhin, K. V.
    Voloshko, O. V.
    PROBLEMELE ENERGETICII REGIONALE, 2024, (03): : 1 - 13
  • [9] Electromagnetic Shielding of Two-Circuit Overhead Power Lines Magnetic Field
    Kuznetsov, B. I.
    Nikitina, T. B.
    Bovdui, I. V.
    Voloshko, O. V.
    Chunikhin, K. V.
    Dubrodeyev, P. N.
    PROBLEMELE ENERGETICII REGIONALE, 2023, (04): : 14 - 29
  • [10] Mitigation of magnetic field under double-circuit overhead transmission line
    Gouda, Osama Elsayed
    El Dein, Adel Z.
    Telkomnika - Indonesian Journal of Electrical Engineering, 2012, 10 (08): : 2272 - 2284