Purpose:To study the outcomes of phacoemulsification in small pupils (<= 4 mm) using pupil expansion devices at a tertiary eye care center in South India.Methods:The study design is prospective, randomized, comparative, and interventional. Mechanical pupil dilatation with iris retractors (group I), B-HEX ring (group II), and Gupta ring (group III) was compared with respect to pupil size achieved (intraoperative), total surgical time, device addition time, complications, endothelial cell loss, and postoperative best corrected visual acuity.Results:Among 36 participants (12 in each group), the mean pupil size, total surgical time, and device addition time were maximum with iris retractors. Intraoperatively, sphincter tear was seen in two eyes in the iris retractors group and one eye in the Gupta ring group. In the B-HEX ring group, only two flanges of the ring could be engaged in two participants, one patient had iris bleeding (during stretching of the iris), and one patient had anterior lens capsular tear. Among all three groups, there was no statistically significant difference in best corrected visual acuity (BCVA), endothelial cell count, and coefficient of variation obtained in the preoperative period, postoperative Day 7 and Day 30, respectively.Conclusion:In our study, in more than 50% of cases, the cause of small pupil was idiopathic/senile. Among nonidiopathic causes, PXF was the most common association. Although iris retractors are cost-effective and give maximum intraoperative dilatation, there is a need of four additional side ports to be made, thus increasing the total surgical time and device addition time. On the other hand, B-HEX and Gupta ring provide comparable intraoperative dilation and device addition time and also have comparable postoperative outcomes in terms of postoperative pupil size and complications.
引用
收藏
页码:S664 / S668
页数:5
相关论文
共 50 条
  • [21] PREPLACED INFERIOR IRIS SUTURE METHOD FOR SMALL PUPIL PHACOEMULSIFICATION
    MASKET, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05): : 518 - 522
  • [22] Numerical stress analysis of the iris tissue induced by pupil expansion: Comparison of commercial devices
    Tan, Royston K. Y.
    Wang, Xiaofei
    Perera, Shamira A.
    Girard, Michael J. A.
    PLOS ONE, 2018, 13 (03):
  • [23] Evaluation of a uniplanar pupil expansion ring in small-pupil cataract surgery: a feasibility study
    Salviat, Flore
    Febbraro, Jean-Luc
    Zuber, Kevin
    Yavchitz, Amelie
    Moran, Sarah
    Gatinel, Damien
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (02) : 489 - 496
  • [24] Evaluation of a uniplanar pupil expansion ring in small-pupil cataract surgery: a feasibility study
    Flore Salviat
    Jean-Luc Febbraro
    Kevin Zuber
    Amélie Yavchitz
    Sarah Moran
    Damien Gatinel
    International Ophthalmology, 2022, 42 : 489 - 496
  • [25] PUPIL ENLARGEMENT FOR SAFE PHACOEMULSIFICATION SURGERY
    OBSTBAUM, SA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05): : 427 - 427
  • [26] Two cases of phacoemulsification in the presence of a small pupil using an iris expander
    Lee, Ha-Eun
    Kim, Joon-Young
    Lee, Da-Eun
    Kang, Jin-Gu
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2019, 43 (01): : 159 - 166
  • [27] A self-made disposable iris retractor in small pupil phacoemulsification
    Jie Li
    Fei Liu
    Wei-Wei Zhang
    Jun-Jun Zhang
    International Journal of Ophthalmology, 2014, (02) : 288 - 292
  • [28] The effect of OASIS iris expander in phacoemulsification surgery of cataract with small pupil
    Zhang, Jing Shang
    Wang, Jin Da
    Wan, Xiu Hua
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [29] A self-made disposable iris retractor in small pupil phacoemulsification
    Li, Jie
    Liu, Fei
    Zhang, Wei-Wei
    Zhang, Jun-Jun
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) : 288 - 292
  • [30] Stabilizing the capsular bag and expanding the pupil with a pupil expansion device
    Zarei-Ghanavati, Siamak
    Bagherian, Homa
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (09): : 1801 - 1803