A self-made disposable iris retractor in small pupil phacoemulsification

被引:0
|
作者
Jie Li [1 ,2 ]
Fei Liu [2 ]
Wei-Wei Zhang [3 ]
Jun-Jun Zhang [1 ]
机构
[1] Department of Ophthalmology, West China Hospital,Sichuan University
[2] Department of Ophthalmology, Nanhai Hospital, Southern Medical University
[3] West China School of Medicine, Sichuan University
关键词
smallpupil; irisretractor; phacoemulsification;
D O I
暂无
中图分类号
R776.1 [白内障];
学科分类号
100212 ;
摘要
AIM:To explore a simple and low-cost self-made disposable flexible iris retractor and study its clinical efficacy and safety in small pupil phacoemulsification.METHODS:Polyproplyenesutureandscalpacupuncture were used to make iris retractor.A prospective study were carried on 50 patients(50 eyes)with a maximally dilated pupil size of 2.5-4.0 mm which underwent phacoemulsification using this self-made iris retractor.Another 50 cases of phacoemulsification with normal pupil size sever as control group.The mean operation time,ultrasound time and ultrasonic power,volume of irrigation fluid were documented intraoperatively.The visual acuity,pupil size and complication were observed on 1d,1wk,1mo and 1y after operation.Corneal endothelial cell was measured at 1mo postoperatively.·RESULT:Pupils could be expanded to approximately4.5-5.5 mm with our self-made iris retractor in operation.No serious postoperative complication was found.Most(88%)of the pupils returned round or oval shape,light reflex restored to varying degrees at the first day after surgery.Best corrected visual acuity stabilized in 37 eyes(74%)at one day,in 43 eyes(86%)at one week,in 44eyes(88%)at one month and 46 eyes(92%)at one year.Compared with the control,more time was needed to complete the operation in the small pupil group.There was no significant difference of the mean ultrasound time,ultrasonic power,volume of irrigation fluid requiredand corneal endothelial cell loss in 1mo follow up between the two groups.CONCLUSION:Our self-made disposable flexible iris retractor could be easy obtained preoperatively or intraoperatively.It performed both safety and efficacy in our clinical trials.This simple self-made device has shown economic and practical values,especially in primary care hospital of the less developed districts.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 50 条
  • [1] A self-made disposable iris retractor in small pupil phacoemulsification
    Li, Jie
    Liu, Fei
    Zhang, Wei-Wei
    Zhang, Jun-Jun
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2014, 7 (02) : 288 - 292
  • [2] A DISPOSABLE IRIS RETRACTOR FOR VITRECTOMY
    CHONG, LP
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 112 (06) : 731 - 732
  • [3] Phacoemulsification in a patient with small pupil and a large iris cyst
    Rotsos, Tryfon
    Diagourtas, Andreas
    Symeonidis, Chrysanthos
    Papaconstantinou, Dimitrios
    Georgopoulos, Gerasimos
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (02) : 278 - 279
  • [4] Small pupil phacoemulsification using iris sutures: A new method?
    Freitas, LL
    Casanova, FH
    Bonomo, PP
    OPHTHALMIC SURGERY LASERS & IMAGING, 2004, 35 (05): : 434 - 437
  • [5] PREPLACED INFERIOR IRIS SUTURE METHOD FOR SMALL PUPIL PHACOEMULSIFICATION
    MASKET, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (05): : 518 - 522
  • [6] Two cases of phacoemulsification in the presence of a small pupil using an iris expander
    Lee, Ha-Eun
    Kim, Joon-Young
    Lee, Da-Eun
    Kang, Jin-Gu
    TURKISH JOURNAL OF VETERINARY & ANIMAL SCIENCES, 2019, 43 (01): : 159 - 166
  • [7] The effect of OASIS iris expander in phacoemulsification surgery of cataract with small pupil
    Zhang, Jing Shang
    Wang, Jin Da
    Wan, Xiu Hua
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Avoiding complications associated with iris retractor use in small pupil cataract extraction
    Masket, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1996, 22 (02): : 168 - 171
  • [9] Small Pupil Phacoemulsification
    Bavbek, Tayfun
    Onal, Sunru
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2005, 35 (02): : 177 - 184
  • [10] SMALL, SELF-MADE COMPANY BEGINS TO THRIVE
    MULCAHY, M
    SEA TECHNOLOGY, 1978, 19 (08) : 23 - &