High impedance fault detection in distribution networks using randomness of zero-sequence current signal: A detrended fluctuation analysis approach

被引:2
|
作者
Gadanayak, Debadatta Amaresh [1 ]
Mishra, Manohar [1 ]
Bansal, Ramesh C. [2 ,3 ]
机构
[1] SOA Deemed Be Univ, Dept Elect & Elect Engn, Bhubaneswar, Odisha, India
[2] Univ Sharjah, Dept Elect Engn, Sharjah, U Arab Emirates
[3] Univ Pretoria, Dept Elect Elect & Comp Engn, Pretoria, South Africa
关键词
Detrended fluctuation analysis; High impedance fault; Zero-sequence current; Fault recognition; Distributed network protection; WAVELET TRANSFORM; METHODOLOGY;
D O I
10.1016/j.apenergy.2024.123452
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Detection of high impedance faults (HIFs) in low and medium voltage distribution networks has always been challenging due to their lower magnitude and random current characteristics. Conventional overcurrent relays are ineffective in detecting HIFs because of the low fault current associated with them. Consequently, existing HIF detection schemes predominantly rely on features extracted from the frequency, time-frequency, or symmetrical component domains. However, these methods are often limited in their effectiveness under specific conditions, such as particular voltage levels, conductor types, or environmental factors, due to the multifaceted nature of HIF currents, which depend upon a variety of factors such as type of materials, voltage level, wetness of the surface, shape of the conductor, and even the weather conditions. On the other hand, due to the intrinsic presence of arcing in the HIF phenomenon, the resultant fault current consistently assumes a random character, and this inherent randomness can be leveraged as a potential feature for fault detection. This paper proposes a new HIF detection method by analyzing the randomness or unpredictability of the fault current signals. The Detrended fluctuation analysis (DFA) is innovatively employed to assess the unpredictability of the lower frequency component of the zero -sequence current by examining its instantaneous amplitude envelope. The accuracy of the proposed approach is verified with extensive simulation data of fault events under diverse operative conditions. The security of the proposed scheme is also verified under several no-fault transient circumstances, such as capacitor switching and load perturbation. The computational efficiency of the method has been verified through the process -in -loop (PIL) simulation using cost-effective hardware.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Zero-sequence voltage trajectory analysis for unbalanced distribution networks on single-line-to-ground fault condition
    Meng, Jun
    Wang, Wen
    Tang, Xin
    Xu, Xianyong
    ELECTRIC POWER SYSTEMS RESEARCH, 2018, 161 : 17 - 25
  • [22] Characteristics of zero-sequence current filtrator for overhead feeder in 10 kV distribution networks
    Qi, Bo
    Chen, Wei-Jiang
    Li, Cheng-Rong
    Zhang, Yuan-Yuan
    Xiao, Meng-Nan
    Gaodianya Jishu/High Voltage Engineering, 2009, 35 (11): : 2832 - 2838
  • [23] Adaptive Zero-Sequence Overcurrent Criterion for Earth Fault Detection for Fault Current Passage Indicators in Resistor Grounded Medium Voltage Networks
    Olejnik, Bartosz
    IEEE ACCESS, 2021, 9 : 63952 - 63965
  • [24] High-impedance faulty feeder detection for cross-country faults in distribution networks based on zero-sequence active power regulation
    Lan, Yuting
    Yu, Kun
    Zeng, Xiangjun
    Cai, Rong
    Deng, Qingbo
    Wu, Chenyu
    He, Shigeng
    Xu, Shijie
    Jia, Youcheng
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2024, 162
  • [25] Zero-Sequence Impedance Estimation in Mutually Coupled Transmission Lines Using Fault Record Data
    Gashteroodkhani, Oveis Asgari
    Majidi, Mehrdad
    Etezadi-Amoli, Mehdi
    2020 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2020,
  • [26] Grounding Fault Direction Algorithm Using Zero-sequence Current in Resonant Grounding System
    Jin X.
    Xue Y.
    Peng Z.
    Yang F.
    Xu B.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (09): : 164 - 170
  • [27] Analysis of Signal Processing Techniques for High Impedance Fault Detection in Distribution Systems
    Lopes, Gabriela Nunes
    Lacerda, Vinicius Albernaz
    Vieira, Jose Carlos Melo
    Coury, Denis Vinicius
    IEEE TRANSACTIONS ON POWER DELIVERY, 2021, 36 (06) : 3438 - 3447
  • [28] A Generalized Open-Phase Fault Detection Technique for Symmetrical Multiphase Machines Using Zero-Sequence Current Constraints
    Sun, Jiawei
    Zheng, Zedong
    Li, Chi
    Wang, Kui
    Li, Yongdong
    IECON 2020: THE 46TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2020, : 3977 - 3981
  • [29] Broken Rotor Bars Detection in Induction Motor by Using Zero-Sequence Signal Injection
    Bossio, G. R.
    de la Barrera, P. M.
    Otero, M.
    Schallschmidt, T.
    Leidhold, R.
    PROCEEDINGS OF THE IECON 2016 - 42ND ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2016, : 1482 - 1487
  • [30] High Impedance Fault Detection and Location in Distribution Networks Using Smart Meters
    Vieira, Francinei L.
    Filho, Jose M. C.
    Silveira, Paulo M.
    Guerrero, Carlos A. V.
    Leite, Marino P.
    2018 18TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2018,