Comparison of two electronic dynamometers for measuring handgrip strength

被引:1
|
作者
Rolsted, Sebastian Keller [1 ,2 ]
Andersen, Kasper Dyrmose [1 ,2 ]
Dandanell, Gustav [1 ,2 ]
Dall, Christian Have [1 ,3 ,4 ]
Zilmer, Camilla Kampp [1 ]
Bulow, Kasper [2 ]
Kristensen, Morten Tange [1 ,4 ]
机构
[1] Copenhagen Univ Hosp, Dept Phys & Occupat Therapy, Copenhagen, Denmark
[2] Univ Coll Absalon, Ctr Hlth & Rehabil, Slagelse, Denmark
[3] Copenhagen Univ Hosp, Dept Cardiol, Copenhagen, Denmark
[4] Univ Copenhagen, Fac Hlth & Med Sci, Dept Clin Med, Copenhagen, Denmark
来源
HAND SURGERY & REHABILITATION | 2024年 / 43卷 / 03期
关键词
Handgrip; Reliability; Validity; Measurements; GRIP STRENGTH; RELIABILITY; AGREEMENT;
D O I
10.1016/j.hansur.2024.101692
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Handgrip strength (HGS) is a strong predictor and easily applicable assessment, indicating a person's physical condition and health. However, many dynamometers are available; therefore, it is essential to ensure that the results of HGS testing using different dynamometers can be used interchangeably. The primary purpose of this study was to investigate the inter -instrument agreement and criterion validity of the Baseline BIMS Digital Grip Dynamometer in comparison with the Jamar electronic dynamometer (Jamar+). Methods: Seventy participants, aged between 23-88 (five men and five women in each decade from 20 to 80+), performed three attempts with each dynamometer (30 -sec break between attempts) in a randomized order and separated with a 5-minute break between dynamometers. Intraclass correlation coefficient (3.1), standard error of measurement and minimal detectable change were used for comparison of the strongest and average strength measured with dynamometers. Jamar+ and Baseline BIMS Digital Grip Dynamometer were new dynamometers and considered calibrated by the manufacturer. Results: The overall Intraclass correlation coefficient was excellent (0.98). An average (SD) difference of 0.68 (2.2) kg (p = 0.04) was seen for the comparison of the strongest attempt for Baseline BIMS minus Jamar+, Correspondingly, for the average of three attempts, it was 0.37 (2.29, p = 0.2) kg. The standard error of measurement (%) and minimal detectable change (%) of the strongest attempt was 1.64 kg (4.2%) and 3.55 kg (9.0%), respectively. Conclusions: Findings indicate low measurement error with high agreement and criterion validity for the comparison of Baseline BIMS Digital Grip Dynamometer and Jamar+ and that results of the two dynamometers can be used interchangeably. (c) 2024 SFCM. Published by Elsevier Masson SAS. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of Sport Type on the Handgrip Strength Change in Young Athletes
    Abe, Takashi
    Abe, Akemi
    Loenneke, Jeremy P.
    AMERICAN JOURNAL OF HUMAN BIOLOGY, 2025, 37 (01)
  • [22] Comparison of Handgrip Strength and Body Composition of Adolescents in Singapore Schools
    Boey, Peggy
    Balasekaran, Govindasamy
    Hui, Stanley Sai-Chuen
    Thor, Dianna
    Govindaswamy, Visvasuresh
    Yi, Tong Zhi
    Cheo, Ng Yew
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 121 - 121
  • [23] COMPARISON BETWEEN CAMRY AND JAMAR DYNAMOMETERS IN MEASURING HAND GRIP STRENGTH AMONG OLDER POST-ACUTE COVID-19 OUTPATIENTS
    Tai, M. H.
    Wan, S. N.
    Engkasan, J.
    Ong, T.
    AGE AND AGEING, 2022, 51 (SUPPL 2)
  • [24] COMPARISON OF DYNAMIC STRENGTH AS MEASURED BY THE CYBEX AND MINI-GYM ISOKINETIC DYNAMOMETERS.
    Freivalds, Andris
    Fotouhi, Donna M.
    1600, (01):
  • [25] A comparison of 3 hand-held dynamometers used to measure hip abduction strength
    Fenter, PC
    Bellew, JW
    Pitts, T
    Kay, R
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2003, 17 (03) : 531 - 535
  • [26] Comparison between two different handgrip systems and protocols on force reduction in handgrip assessment
    De Dobbeleer, Liza
    Beckwee, David
    Arnold, Pauline
    Baudry, Stephane
    Beyer, Ingo
    Demarteau, Jeroen
    Lieten, Siddhartha
    Punie, Ynes
    Bautmans, Ivan
    GERONTOLOGY, 2023, 69 (10) : 1259 - 1268
  • [27] ELECTRONIC DATA PROCESSING CENTER FOR ENGINE DYNAMOMETERS
    MELCHER, K
    SAE TRANSACTIONS, 1967, 75 : 149 - &
  • [28] Measuring grip strength in normal adults: Reference ranges and a comparison of electronic and hydraulic instruments
    Massy-Westropp, N
    Health, M
    Rankin, W
    Ahern, M
    Krishnan, J
    Hearn, TC
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2004, 29A (03): : 514 - 519
  • [29] Handgrip Strength in Fibromyalgia
    Koklu, Kurtulus
    Sarigul, Merve
    Ozisler, Zuhal
    Sirzai, Hulya
    Ozel, Sumru
    ARCHIVES OF RHEUMATOLOGY, 2016, 31 (02) : 158 - 161
  • [30] Comparison Between Handgrip Dynamometry and Manual Muscle Testing Performed by Registered Dietitians in Measuring Muscle Strength and Function of Hospitalized Patients
    Dowhan, Lindsay
    DeChicco, Robert
    Welsh, Renee
    Wehner, Rebecca
    Habib, Monica
    Hipskind, Peggy
    Cresci, Gail
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2016, 40 (07) : 951 - 958