Effect of photons and electrons on the over-response of optical fiber X-ray sensors

被引:0
|
作者
He, Bo [1 ]
Xie, Tianci [1 ]
Zhang, Bin [1 ]
Qian, Jinqian [1 ]
Li, Haopeng [1 ]
Shi, Qieming [1 ]
Hao, Wenjing [1 ]
Qin, Zhuang [2 ]
Lewis, Elfed [3 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab In Fiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Heilongjiang Univ, Elect Engn Coll, Minist Educ China, Harbin 50001, Peoples R China
[3] Univ Limerick, Opt Fiber Sensors Res Ctr, Limerick, Ireland
基金
中国国家自然科学基金; 爱尔兰科学基金会;
关键词
Radiotherapy fiber X-ray sensors; Over-response; Monte Carlo simulation; RADIATION DOSIMETER; DETECTORS;
D O I
10.1016/j.sna.2024.115649
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Optical fiber X-ray sensors are prone to over -response compared to ionization chambers (ICs) when used to measure the percentage depth dose (PDD) curves and off axis ratio (OAR) curves. Investigating this phenomenon is crucial for the successful adoption of these sensors in clinical radiotherapy. Compared with ion chambers and other water equivalent dosimeters, the fiber X-ray sensors using high Z eff scintillators (Gd 2 O 2 S:Tb) have generally higher mass attenuation coefficients. In this case, the response of scintillators to photons needs to be considered. In this article, a Monte -Carlo (MC) software package BEAMnrc was used to simulate the distribution of photon and electron fluxes in a clinical based water phantom, besides the energy deposition of air and Gd 2 O 2 S:Tb in varying energy was also simulated. The distribution of the photon and electron fluxes in the horizontal (radial) direction at a fixed 10 cm water depth was studied, as well as the fluxes in the vertical (depth) direction. An embedded -structure fiber X-ray sensor was used for the experimental measurements. The simulation results indicate that, in the horizontal direction, there are many photons remain outside the radiation field. In the vertical direction, as the size of the radiation field increases, the maximum point of the photon flux shifts towards a deeper water depth. These behavior of photon flux is consistent with the fiber X-ray sensors measurement. However, the maximum point of the electron flux remains unchanged in the vertical direction. In the horizontal direction, the electron flux decreases rapidly, and this scenario is similar to the case when using the ion chamber. Results of analyzing the spectra inside and outside the radiation field show that there is a large number of photons with energy below 0.2 MeV outside the radiation field, and the proportion of these low -energy photons is greater than 60 %. The findings indicate that the fiber X-ray sensors ' over -response can be primarily attributed to the lower energy scattered photons.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Quantum Dots Microstructured Optical Fiber for X-ray Detection
    DeHaven, S. L.
    Williams, P. A.
    Burke, E. R.
    [J]. 42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE, 2016, 1706
  • [32] Storage of X-ray photons in a crystal resonator
    K.-D. Liss
    R. Hock
    M. Gomm
    B. Waibel
    A. Magerl
    M. Krisch
    R. Tucoulou
    [J]. Nature, 2000, 404 : 371 - 373
  • [33] Storage of X-ray photons in a crystal resonator
    Liss, KD
    Hock, R
    Gomm, M
    Waibel, B
    Magerl, A
    Krisch, M
    Tucoulou, R
    [J]. NATURE, 2000, 404 (6776) : 371 - 373
  • [34] Merging of x-ray photons in an atomic field
    Hopersky, A. N.
    Nadolinsky, A. M.
    Novikov, S. A.
    [J]. JOURNAL OF PHYSICS B-ATOMIC MOLECULAR AND OPTICAL PHYSICS, 2017, 50 (06)
  • [35] Applied physics: Squeezing x-ray photons
    Metzger, TH
    [J]. SCIENCE, 2002, 297 (5579) : 205 - 206
  • [36] Parametric down conversion of X-ray photons
    Adams, B
    Fernandez, P
    Lee, WK
    Materlik, G
    Mills, DM
    Novikov, DV
    [J]. JOURNAL OF SYNCHROTRON RADIATION, 2000, 7 (02) : 81 - 88
  • [37] Ghost imaging with paired x-ray photons
    Schori, A.
    Borodin, D.
    Tamasaku, K.
    Shwartz, S.
    [J]. PHYSICAL REVIEW A, 2018, 97 (06)
  • [38] Ghost Imaging with Paired X-ray Photons
    Schori, A.
    Borodin, D.
    Tamasaku, K.
    Shwartz, S.
    [J]. 2018 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2018,
  • [39] CHANNELING OF PHOTONS AND NEW X-RAY OPTICS
    KUMAKHOV, MA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 48 (1-4): : 283 - 286
  • [40] HOW X-RAY PHOTONS CAUSE DAMAGE
    Arnaud, Celia
    [J]. CHEMICAL & ENGINEERING NEWS, 2016, 94 (03) : 8 - 8