Research on Ultraviolet Characteristic Parameters of DC-Positive Polarity Corona Discharge on Conductors

被引:0
|
作者
Dai, Youquan [1 ]
Zhang, Zhanlong [1 ]
Dong, Zijian [1 ]
Wu, Yongye [1 ,2 ]
Jun, Deng [1 ]
机构
[1] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] Chengdu Power Supply Co, Chengdu 610002, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 08期
基金
中国国家自然科学基金;
关键词
corona discharge; UV imaging; photon number; gain; observation distance; AIR-PRESSURE; PERFORMANCE; VOLTAGES;
D O I
10.3390/app14083258
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of corona-related defects in transmission lines has been included in the work of transmission line defect detection. Ultraviolet detection technology has gradually been widely applied in the field of corona discharge detection. However, the current research on the application of ultraviolet detection technology in transmission lines is relatively simple and mainly limited to using changes in the photon count to determine whether corona discharge has occurred. To address this, this study used a mini corona cage to simulate transmission lines and measured the changes in the photon count, spot area, and corona current in the corona inception process of different types of smooth, stainless-steel conductors. This study also investigated the variations in the photon count and spot area depending on conductor corona intensity, ultraviolet imager gain, and observation distance. The results show that the photon count and spot area can, to some extent, reflect the intensity of corona discharge. Both the photon count and spot area exhibited quadratic relationships with the voltage. As the observation distance increased, both the photon count and spot area showed exponential decay. The photon count exhibited a trend of initially increasing, then decreasing, and finally increasing again with the increase of gain, while the spot area showed exponential growth with increasing gain. The photon count and spot area can complement each other to identify and characterize the intensity of corona discharge.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] The Current-Voltage Characteristics for Electrode Geometry Model of Positive DC Corona Discharge in Air
    Wardaya, Asep Yoyo
    Muhlisin, Zaenul
    Suseno, Jatmiko Endro
    Nur, Muhammad
    Triadyaksa, Pandji
    Khumaeni, Ali
    Hadi, Susilo
    Sarwoko, Eko Adi
    Windarta, Jaka
    GAZI UNIVERSITY JOURNAL OF SCIENCE, 2022, 35 (03): : 1140 - 1150
  • [42] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    JOURNAL OF APPLIED PHYSICS, 2007, 101 (02)
  • [43] Electrical study of DC positive corona discharge in dry and humid air containing carbon dioxide
    Lachaud, S
    Loiseau, JF
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2003, 24 (01): : 67 - 74
  • [44] Properties of positive DC corona discharge in iced electrode system under low atmospheric pressure
    Sima, Wen-Xia
    Feng, Jie
    Yang, Qing
    Lai, Xiang-Ping
    Yu, D.
    Farzaneh, M.
    Zhang, J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2007, 27 (27): : 13 - 18
  • [45] Revisiting the positive DC corona discharge theory: Beyond Peek's and Townsend's law
    Monrolin, Nicolas
    Praud, Olivier
    Plouraboue, Franck
    PHYSICS OF PLASMAS, 2018, 25 (06)
  • [46] A Numerical Simulation Study on DC Positive Corona Discharge Characteristics at the Conductor's Tip Defect
    Wang, Shenghui
    Mai, Jiamin
    Wang, Lihong
    APPLIED SCIENCES-BASEL, 2023, 13 (18):
  • [47] Positive DC corona discharge in N2-NO-CO2-O2 mixtures
    Hensel, K
    Hayashi, N
    Yamabe, C
    Morvová, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2002, 41 (01): : 336 - 345
  • [48] Spectroscopic image processing and space charge field for positive DC glow corona discharge in atmosphere
    Yang, JB
    Izawa, Y
    Nishijima, K
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 813 - 816
  • [49] Calculation of ozone generation by positive dc corona discharge in coaxial wire-cylinder reactors
    Yehia, Ashraf
    Journal of Applied Physics, 2007, 101 (02):
  • [50] Influence of humidity on pulse shape parameters of positive corona discharges in air at DC voltage
    Luehring, Ulrich
    Wienold, Daniel
    Jenau, Frank
    2017 1ST IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2017 17TH IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2017,