Research on Ultraviolet Characteristic Parameters of DC-Positive Polarity Corona Discharge on Conductors

被引:0
|
作者
Dai, Youquan [1 ]
Zhang, Zhanlong [1 ]
Dong, Zijian [1 ]
Wu, Yongye [1 ,2 ]
Jun, Deng [1 ]
机构
[1] Chongqing Univ, Sch Elect Engn, Chongqing 400044, Peoples R China
[2] Chengdu Power Supply Co, Chengdu 610002, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 08期
基金
中国国家自然科学基金;
关键词
corona discharge; UV imaging; photon number; gain; observation distance; AIR-PRESSURE; PERFORMANCE; VOLTAGES;
D O I
10.3390/app14083258
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The detection of corona-related defects in transmission lines has been included in the work of transmission line defect detection. Ultraviolet detection technology has gradually been widely applied in the field of corona discharge detection. However, the current research on the application of ultraviolet detection technology in transmission lines is relatively simple and mainly limited to using changes in the photon count to determine whether corona discharge has occurred. To address this, this study used a mini corona cage to simulate transmission lines and measured the changes in the photon count, spot area, and corona current in the corona inception process of different types of smooth, stainless-steel conductors. This study also investigated the variations in the photon count and spot area depending on conductor corona intensity, ultraviolet imager gain, and observation distance. The results show that the photon count and spot area can, to some extent, reflect the intensity of corona discharge. Both the photon count and spot area exhibited quadratic relationships with the voltage. As the observation distance increased, both the photon count and spot area showed exponential decay. The photon count exhibited a trend of initially increasing, then decreasing, and finally increasing again with the increase of gain, while the spot area showed exponential growth with increasing gain. The photon count and spot area can complement each other to identify and characterize the intensity of corona discharge.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Ultraviolet Characteristic Parameter of Needle-plate Model AC/DC Corona Discharge
    Li Z.
    Jiang X.
    Li L.
    Hu Q.
    Hu J.
    Zhang Z.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (05): : 1677 - 1684
  • [2] PHYSICAL CONDITIONS FOR THE PRODUCTION OF A DC CORONA DISCHARGE IN SMOOTH CONDUCTORS
    ALEKSANDROV, GN
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1956, 1 (12): : 2554 - 2565
  • [3] Ozone production in the negative DC corona: The dependence of discharge polarity
    Chen, JH
    Davidson, JH
    PLASMA CHEMISTRY AND PLASMA PROCESSING, 2003, 23 (03) : 501 - 518
  • [4] Ozone Production in the Negative DC Corona: The Dependence of Discharge Polarity
    Junhong Chen
    Jane H. Davidson
    Plasma Chemistry and Plasma Processing, 2003, 23 : 501 - 518
  • [5] Research on Ultraviolet Detection of Insulator Corona Discharge
    Liu, Shibo
    Huang, Dagui
    Zhang, Yongjie
    Zou, Xiang
    Liu, Yulu
    Huang, Siyuan
    Zhang, Lieping
    2014 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (IEEE ICMA 2014), 2014, : 1347 - 1352
  • [6] Polarity reversal charging of polypropylene films under DC corona discharge
    Zhang, B
    Zhou, YX
    Wang, NH
    Liang, XD
    Guan, ZC
    Takada, T
    JOURNAL OF ELECTROSTATICS, 2005, 63 (6-10) : 657 - 663
  • [7] POLARITY DEPENDENCE OF ELECTRODE EROSION UNDER DC CORONA DISCHARGE.
    Donovan, R.P.
    Lawless, Philip A.
    Smith, Daryl D.
    Microcontamination, 1986, 4 (05): : 38 - 49
  • [8] Experimental observation of negative differential characteristic of corona discharge in ultraviolet spectrum
    Kolcunova, I.
    Cimbala, R.
    Petras, J.
    Kurimsky, J.
    Dolnik, B.
    Dzmura, J.
    Balogh, J.
    JOURNAL OF ELECTROSTATICS, 2017, 88 : 139 - 147
  • [9] Influence of Air Pressure on Positive DC Corona Inception Voltage of Stranded Conductors in the Corona cage
    Meng, Xiaobo
    Bian, Xingming
    Chen, Fenglin
    Yang, Yingjian
    Wang, Liming
    Guan, Zhicheng
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [10] An Improved Fluid Model Study: The Effect of Cross-Section Geometry on Positive Corona Discharge on DC Transmission Conductors
    Zhang, Xinchun
    Wang, Feng
    Li, Anqi
    Fan, Weili
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2020, 48 (08) : 2846 - 2855