A comparison of intraocular pressure measurement using SUOER SW-500 rebound tonometer and conventional reusable Goldmann prisms

被引:0
|
作者
Chaung, Jia Quan [1 ,2 ]
Sangapillai, Thanendthire [1 ]
Quilat, Karen Kate [1 ]
Perera, Shamira [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore City, Singapore
[2] Singapore Eye Res Inst, Singapore City, Singapore
[3] Duke NUS Med Sch, Singapore City, Singapore
关键词
glaucoma; rebound tonometer; IOP; intraocular pressure; Goldmann applanation tonometry; APPLANATION TONOMETER; ICARE; GLAUCOMA; AGREEMENT;
D O I
10.3389/fmed.2024.1269332
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: To determine the agreement between intraocular pressure (IOP) measurements using conventional Goldmann applanation tonometry (GA(1,2)T) and SUOER SW-500 Rebound Tonometer. Methods: This was a retrospective observational study where 205 eyes of 106 glaucoma patients had their IOPs measured by 2 fellowship trained ophthalmologists. Data were analyzed using the Bland-Altman method of differences. Correlation was measured using the Pearson coefficient. Results: Most of our patients were Chinese (88.7%) and female (51.9%). The average age was 66.9 years. The range of IOPs as measured by GAT was 2 to 58 mm Hg. Using the Bland-Altman method to compare GAT and SUOER SW-500 Rebound Tonometer. The tonometer overestimated the IOP by 0.5 mm Hg in the right eye and underestimated it by 0.1 mm Hg in the left eye. Overall, the tonometer overestimated the IOP by 0.2 mmHg. The Tonometer IOP correlated well with GAT, with a Pearson coefficient of correlation(r) of 0.89 (p < 0.001) for the right eye and 0.86 (p < 0.001) for the left eye, respectively. In patients with GAT IOP >= 21 mm Hg (n = 25), the Tonometer underestimated the IOP by 2.96 mm Hg. Discussion: The IOP measurements from the SUOER SW-500 Rebound Tonometer correlates well with the conventional GAT in measuring the IOP within normal ranges of IOP. SUOER SW-500 Rebound Tonometer may be of use, especially if the risk of transmission of infection is high considering that the probes are disposable. It is easy to use and its small size and portability makes it useful in situations where the patient is unable to be examined at the slit lamp.
引用
收藏
页数:7
相关论文
共 35 条
  • [31] Comparison of intraocular pressure measurements using Goldmann tonometer, I-care pro, Tonopen XL, and Schiotz tonometer in patients after Descemet stripping endothelial keratoplasty
    Ohana, Oded
    Varssano, David
    Shemesh, Gabi
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (07) : 579 - 583
  • [32] COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT USING REBOUND AND APPLANATION TONOMETRY IN LOGGERHEAD (CARETTA CARETTA) SEA TURTLES
    Lamagna, Barbara
    Affuso, Andrea
    Micieli, Fabiana
    Mennonna, Giuseppina
    Meomartino, Leonardo
    Della Valle, Giovanni
    Ciampa, Mariapia
    Treglia, Gianluca
    Hochscheid, Sandra
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2021, 52 (02) : 604 - 609
  • [33] Comparison of intraocular pressure adjusted by central corneal thickness or corneal biomechanical properties as measured in glaucomatous eyes using noncontact tonometers and the Goldmann applanation tonometer
    Yaoeda, Kiyoshi
    Fukushima, Atsushi
    Shirakashi, Motohiro
    Fukuchi, Takeo
    CLINICAL OPHTHALMOLOGY, 2016, 10 : 829 - 834
  • [34] Measurement of intraocular pressure using the Tono-Pen in comparison with Goldmann applanation tonometry - a clinical study in 100 eyes
    Deuter, CME
    Schlote, T
    Hahn, GA
    Bende, T
    Derse, M
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2002, 219 (03) : 138 - 142
  • [35] Measurement of the difference in intraocular pressure between the sitting and lying body positions in healthy subjects: direct comparison of the Icare Pro with the Goldmann applanation tonometer, Pneumatonometer and Tonopen XL
    Barkana, Yaniv
    Gutfreund, Shay
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (07): : 608 - 614